Vitrectomy in Congenital Vitreous Pathologies

Congenital vitreous diseases are the result of embryological development defects of the vitreous. These diseases have a wide spectrum including congenital vitreous disorders and genetically impaired vitreous structure. Also, these diseases are the first diseases that should come to mind in vitreous and retinal pathologies seen in the early age group. In many of them, pars plana vitrectomy has an important role in the treatment. Due to the disease pathophysiology and age of the patients, they differ from the standard pars plana vitrectomy. In this review, congenital vitreous pathologies and the vitrectomy method applied in the treatment of these pathologies will be discussed.

2020 ◽  
Vol 76 (1) ◽  
pp. 14-23
Author(s):  
Štěpán Rusňák ◽  
Lenka Hecová

Purpose: Penetrating eye trauma with an intraocular foreign body is very frequent, especially in men in their productive age. Pars plana vitrectomy would be the standard surgical method at our department. However, in indicated cases (metallic intraocular bodies in the posterior eye segment in young patients with well transparent ocular media without detached ZSM and without any evident vitreoretinal traction) transscleral extraction of the intraocular foreign body is performed using the exo magnet, eventually endo magnet with a minimal PPV without PVD induction under the visual control of endo-illumination. Materials and Methods: Between June 2003 and June 2018, 66 eyes of 66 patients diagnosed with a penetrating eye trauma caused by an intraocular foreign body located in the posterior eye segment were treated. In 18 eyes (27,3 %) with a metallic foreign body in vitreous (body) or in retina, no PPV or a minimal PPV without PVD was used as a surgical method. In the remaining 48 eyes (72,7 %), a standard 20G, respectively 23G PPV method were used together with PVD induction and the foreign body extraction via endo or exo magnet. Conclusions: As demonstrated by our survey/study, in the cases of a thoroughly considered indication an experimented vitreoretinal surgeon can perform a safe NCT transscleral extraction from the posterior eye segment via exo magnet, eventually endo magnet under the visual control of a contact display system with a minimal PPV. Thereby, the surgeon can enhance the patient´s chance to preserve their own lens and its accommodative abilities as well as reduce the risk of further surgical interventions of the afflicted eye.


2020 ◽  
pp. bjophthalmol-2020-317214
Author(s):  
Hasan Naveed ◽  
Fong May Chew ◽  
Hanbin Lee ◽  
Edward Hughes ◽  
Mayank A Nanavaty

PurposeTo assess whether pars plana vitrectomy (PPV) is an aerosol-generating procedure (AGP) in an ex vivo experimental model.MethodsIn this ex vivo study on 10 porcine eyes, optical particle counter was used to measure particles ≤10 μm using cumulative mode in the six in-built channels: 0.3 μm, 0.5 μm, 1 μm, 2.5 μm, 5 μm and 10 μm aerosols during PPV. Two parts of the study were as follows: (1) to assess the pre-experimental baseline aerosol count in the theatre environment where there are dynamic changes in temperature and humidity and (2) to measure aerosol generation with 23-gauge and 25-gauge set-up. For each porcine eye, five measurements were taken for each consecutive step in the experiment including pre-PPV, during PPV, fluid–air exchange (FAX) and venting using a flute with 23-gauge set-up and a chimney with 25-gauge set-up. Therefore, a total of 200 measurements were recorded.ResultsWith 23-gauge and 25-gauge PPV, there was no significant difference in aerosol generation in all six channels comparing pre-PPV versus PPV or pre-PPV versus FAX. Venting using flute with 23-gauge PPV showed significant reduction of aerosol ≤1 μm. Air venting using chimney with 25-gauge set-up showed no significant difference in aerosol of ≤1 μm. For cumulative aerosol counts of all particles measuring ≤5 μm, compared with pre-PPV, PPV or FAX, flute venting in 23-gauge set-up showed significant reduction unlike the same comparison for chimney venting in 25-gauge set-up.ConclusionPPV and its associate steps do not generate aerosols ≤10 μm with 23-gauge and 25-gauge set-ups.


Author(s):  
Ljubo Znaor ◽  
Aleksej Medic ◽  
Susanne Binder ◽  
Ana Vucinovic ◽  
Josipa Marin Lovric ◽  
...  

2017 ◽  
Vol 8 (1) ◽  
pp. 35-39 ◽  
Author(s):  
Zhong Lin ◽  
Nived Moonasar ◽  
Rong Han Wu ◽  
Robin R. Seemongal-Dass

Purpose: Traditionally acceptable methods of anesthesia for vitrectomy surgery are quite varied. However, each of these methods has its own potential for complications that can range from minor to severe. The surgery procedure of vitrectomy for symptomatic vitreous floaters is much simpler, mainly reflecting in the nonuse of sclera indentation, photocoagulation, and the apparently short surgery duration. The use of 27-gauge cannulae makes the puncture of the sclera minimally invasive. Hence, retrobulbar anesthesia, due to its rare but severe complications, seemed excessive for this kind of surgery. Method: Three cases of 27-gauge, sutureless pars plana vitrectomy for symptomatic vitreous floaters with topical anesthesia are reported. Results: The vitrectomy surgeries were successfully performed with topical anesthesia (proparacaine, 0.5%) without operative or postoperative complications. Furthermore, none of the patients experienced apparent pain during or after the surgery. Conclusion: Topical anesthesia can be considered for 27-guage vitrectomy in patients with symptomatic vitreous floaters.


Sign in / Sign up

Export Citation Format

Share Document