optical particle counter
Recently Published Documents


TOTAL DOCUMENTS

157
(FIVE YEARS 46)

H-INDEX

19
(FIVE YEARS 3)

2021 ◽  
Author(s):  
Joseph Girdwood ◽  
Warren Stanley ◽  
Chris Stopford ◽  
David Brus

Abstract. Unmanned aerial vehicles (UAVs) have great potential to be utilised as an airborne platform for measurement of atmospheric particulates and droplets. In particular, the spatio-temporal resolution of UAV measurements could be of use for the characterisation of aerosol, cloud, and radiation (ACR) interactions, which contribute to the largest uncertainty in the radiative forcing of climate change throughout the industrial era (Zelinka et al., 2014). Due to the infancy of the technique however, UAV-instrument combinations must be extensively validated to ensure the data is of high accuracy and reliability. This paper presents an evaluation of a particular UAV-instrument combination: the FMI-Talon fixed-wing UAV and the UCASS open-path optical particle counter. The performance of the UCASS was previously evaluated on a multi-rotor airframe by Girdwood et al. (2020). However, fixed-wing measurements present certain advantages—namely endurance, platform stability, and maximum altitude. Airflow simulations were utilised to define limiting parameters on UAV sampling—that is, an angle of attack limit of 10° and a minimum airspeed of 20 ms−1—which were then applied retroactively to field campaign data as rejection criteria. The field campaign involved an inter-comparison with reference instrumentation mounted on a research station, which the UAV flew past through stratus cloud. The effective diameter measured by the UAV largely agreed within 2 μm. The droplet number concentration agreed within 15 % on all but 5 profiles. It was concluded that UCASS would benefit from a mechanical redesign to avoid calibration drifts, and UAV attitude variations during measurement should be kept to a minimum.


2021 ◽  
Vol 14 (9) ◽  
pp. 6101-6118
Author(s):  
Zixia Liu ◽  
Martin Osborne ◽  
Karen Anderson ◽  
Jamie D. Shutler ◽  
Andy Wilson ◽  
...  

Abstract. We first validate the performance of the Portable Optical Particle Spectrometer (POPS), a small light-weight and high sensitivity optical particle counter, against a reference scanning mobility particle sizer (SMPS) for a month-long deployment in an environment dominated by biomass burning aerosols. Subsequently, we examine any biases introduced by operating the POPS on a quadcopter drone, a DJI Matrice 200 V2. We report the root mean square difference (RMSD) and mean absolute difference (MAD) in particle number concentrations (PNCs) when mounted on the UAV and operating on the ground and when hovering at 10 m. When wind speeds are low (less than 2.6 m s−1), we find only modest differences in the RMSDs and MADs of 5 % and 3 % when operating at 10 m altitude. When wind speeds are between 2.6 and 7.7 m s−1 the RMSDs and MADs increase to 26.2 % and 19.1 %, respectively, when operating at 10 m altitude. No statistical difference in PNCs was detected when operating on the UAV in either ascent or descent. We also find size distributions of aerosols in the accumulation mode (defined by diameter, d, where 0.1 ≤ d ≤ 1 µm) are relatively consistent between measurements at the surface and measurements at 10 m altitude, while differences in the coarse mode (here defined by d >  1 µm) are universally larger. Our results suggest that the impact of the UAV rotors on the POPS PNCs are small at low wind speeds, but when operating under a higher wind speed of up to 7.6 m s−1, larger discrepancies occur. In addition, it appears that the POPS measures sub-micron aerosol particles more accurately than super-micron aerosol particles when airborne on the UAV. These measurements lay the foundations for determining the magnitude of potential errors that might be introduced into measured aerosol particle size distributions and concentrations owing to the turbulence created by the rotors on the UAV.


Author(s):  
Giuseppe Mongelluzzo ◽  
Gabriele Franzese ◽  
Fabio Cozzolino ◽  
Francesca Esposito ◽  
Alan Cosimo Ruggeri ◽  
...  

Author(s):  
Moritz W. J. Schramm ◽  
Asim J. Sheikh ◽  
Rebecca Chave-Cox ◽  
James McQuaid ◽  
Rachel C. W. Whitty ◽  
...  

Abstract Background Aerosol is a health risk to theatre staff. This laboratory study quantifies the reduction in particulate matter aerosol concentrations produced by electrocautery and drilling when using mitigation strategies such as irrigation, respirator filtration and suction in a lab environment to prepare for future work under live OR conditions. Methods We combined one aerosol-generating procedure (monopolar cutting or coagulating diathermy or high-speed diamond- or steel-tipped drilling of cadaveric porcine tissue) with one or multiple mitigation strategies (instrument irrigation, plume suction and filtration using an FFP3 respirator filter) and using an optical particle counter to measure particulate matter aerosol size and concentrations. Results Significant aerosol concentrations were observed during all aerosol-generating procedures with concentrations exceeding 3 × 106 particles per 100 ml. Considerable reductions in concentrations were observed with mitigation. In drilling, suction, FFP3 filtration and wash alone respectively reduced aerosol by 19.3–31.6%, 65.1–70.8% and 97.2 to > 99.9%. The greatest reduction (97.38 to > 99.9%) was observed when combining irrigation and filtration. Coagulating diathermy reduced concentrations by 88.0–96.6% relative to cutting, but produced larger particles. Suction alone, and suction with filtration reduced aerosol concentration by 41.0–49.6% and 88.9–97.4% respectively. No tested mitigation strategies returned aerosol concentrations to baseline. Conclusion Aerosol concentrations are significantly reduced through the combined use of filtration, suction and irrigation. Further research is required to characterise aerosol concentrations in the live OR and to find acceptable exposure limits, and in their absence, to find methods to further reduce exposure to theatre staff.


2021 ◽  
Author(s):  
Nick M. Wilson ◽  
Guy B. Marks ◽  
Andrew Eckhardt ◽  
Alyssa Clarke ◽  
Francis Young ◽  
...  

AbstractBackgroundExhaled respirable aerosols (<5 µm diameter) present a high risk of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) transmission. Many guidelines recommend using aerosol precautions during ‘aerosol generating procedures’ (AGPs) and droplet (>5 µm) precautions at other times. However, there is emerging evidence that respiratory activities such as cough and not AGPs are the important source of aerosols.MethodsWe used a novel chamber with an optical particle counter sampling at 100 L/min to count and size-fractionate all exhaled particles (0.5-25 µm). We compared emissions from ten healthy subjects during respiratory ‘activities’ (quiet breathing, talking, shouting, forced expiratory maneuvers, exercise and coughing) with respiratory ‘therapies’ designated as AGPs: high flow nasal oxygen (HFNO) and single or dual circuit non-invasive positive pressure ventilation, NIPPV-S and NIPPV-D, respectively. Activities were repeated wearing facemasks.ResultsCompared to quiet breathing, respiratory activities increased particle counts between 34.6-fold (95% confidence interval [CI], 15.2 to 79.1) during talking, to 370.8-fold (95% CI, 162.3 to 847.1) during coughing (p<0.001). During quiet breathing, HFNO at 60 L/min increased counts 2.3-fold (95% CI, 1.2 to 4.4) (p=0.03) and NIPPV-S and NIPPV-D at 25/10 cm H2O increased counts by 2.6-fold (95% CI, 1.7 to 4.1) and 7.8-fold (95% CI, 4.4 to 13.6) respectively (p<0.001). During activities, respiratory therapies and facemasks reduced emissions compared to activities alone.ConclusionTalking, exertional breathing and coughing generate substantially more aerosols than the respiratory therapies HFNO and NIPPV which can reduce total emissions. The risk of aerosol exposure is underappreciated and warrants widespread targeted interventions.


2021 ◽  
Author(s):  
Zixia Liu ◽  
Martin Osborne ◽  
Jim Haywood ◽  
Karen Anderson ◽  
Jamie D. Shulter ◽  
...  

Abstract. The Printed Optical Particle Spectrometer (POPS) is an advanced and small low-cost, light-weight, and high-sensitivity optical particle counter (OPC), particularly designed for deployed on unpiloted aerial vehicles (UAVs) and balloon sondes. We report the performance of the POPS against a reference scanning mobility particle sizer (SMPS) and an airborne passive cavity aerosol spectrometer probe (PCASP) while the POPS is operated on the ground and also while operated on a quadcopter drone, a DJI Matrice 200 V2. This is the first such documented test of the performance of a POPS instrument on a UAV. We investigate the root mean square difference (RMSD) and mean absolute difference (MAD) in particle number concentrations (PNCs) when operating on the ground and on the Matrice 200. When windspeeds are less than 2.6 m/s, we find only modest differences in the RMSDs and MADs of 2.4 % and 2.3 % respectively when operating on the ground, and to 5 % and 3 % when operating at 10m altitude. When windspeeds are greater than 2.6 m/s but less than 7.7 m/s the RMSDs and MADs increase to 10.2 % and 7.8 % respectively when operating on the ground, and 26.2 % and 19.1 %, respectively when operating at 10m altitude. No statistical difference in PNCs was detected when operating on the UAV in either ascent or descent. We also find size distributions of aerosols in the accumulation mode (here defined by diameter, d, where 0.1 ≤ d ≤ 1 µm) are relatively consistent between measurements at the surface and measurements at 10m altitude with RMSD and MAD of less than 21.6 % and 15.7 %, respectively. However, the differences between coarse mode (here defined by d > 1 µm) are universally larger than those measured at the surface with a RMSD and MAD approaching 49.5 % and 40.4 %. Our results suggest that the impact of the UAV rotors on the POPS does not unduly affect the performance of the POPS for wind speed less than 2.6 m/s, but when operating under higher wind speed of up to 7.6 m/s, larger discrepancies are noted. In addition to this, it appears that the POPS measures sub-micron aerosol particles more accurately than super-micron aerosol particles when airborne on the UAV. These measurements lay the foundations for determining the magnitude of potential errors that might be introduced into measured aerosol particle size distributions and concentrations owing to the turbulence created by the rotors on the UAV.