scholarly journals Chemometrics-Assisted UV Spectrophotometric and RP-HPLC Methods for the Simultaneous Determination of Tolperisone Hydrochloride and Diclofenac Sodium in their Combined Pharmaceutical Formulation

2013 ◽  
Vol 81 (4) ◽  
pp. 983-1001 ◽  
Author(s):  
Nikunj Rameshbhai Gohel
2016 ◽  
Vol 99 (6) ◽  
pp. 1490-1498 ◽  
Author(s):  
Amal B Ahmed ◽  
Maha M Abdelrahman ◽  
Nada S Abdelwahab ◽  
Fathy M Salama

Abstract Newly established TLC-densitometric and RP-HPLC methods were developed and validated for the simultaneous determination of Piracetam (PIR) and Vincamine (VINC) in their pharmaceutical formulation and in the presence of PIR and VINC degradation products, PD and VD, respectively. The proposed TLC-densitometric method is based on the separation and quantitation of the studied components using a developing system that consists of chloroform–methanol–glacial acetic acid–triethylamine (8 + 2 + 0.1 + 0.1, v/v/v/v) on TLC silica gel 60 F254 plates, followed by densitometric scanning at 230 nm. On the other hand, the developed RP-HPLC method is based on the separation of the studied components using an isocratic elution of 0.05 M KH2PO4 (containing 0.1% triethylamine adjusted to pH 3 with orthophosphoric acid)–methanol (95 + 5, v/v) on a C8 column at a flow rate of 1 mL/min with diode-array detection at 230 nm. The developed methods were validated according to International Conference on Harmonization guidelines and demonstrated good accuracy and precision. Moreover, the developed TLC-densitometric and RP-HPLC methods are suitable as stability-indicating assay methods for the simultaneous determination of PD and VD either in bulk powder or pharmaceutical formulation. The results were statistically compared with those obtained by the reported RP-HPLC method using t- and F-tests.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Hina Shamshad ◽  
Agha Zeeshan Mirza

Abstract Background Present work describes a fast, simple, and sensitive procedure for the simultaneous determination of cetirizine in the presence of quinolones using diclofenac sodium as an internal standard. The present work was designed to analyze these compounds in pharmaceutical and clinical labs being economical for use. Results The mobile phase consisted of the simple composition of methanol, acetonitrile, and water in a ratio of 50:20:30 with a pH adjusted to 3.1 at a flow rate of 1 mL min−1. The UV detection was performed at 225 nm. The linearity was assessed over the range of 2.5–50 μg mL−1 for all drugs. The parameters such as accuracy, precision, linearity (>0.999), and sensitivity were satisfactory. Conclusion The method was equally applicable for formulation and human serum with recovery values between 95 and 105%. The results of the method were validated statistically according to ICH guidelines.


2014 ◽  
Vol 97 (3) ◽  
pp. 791-797 ◽  
Author(s):  
Hiral Soni ◽  
Charmy Kothari ◽  
Deepak Khatri ◽  
Priti Mehta

Abstract Validated RP-HPLC, HPTLC, and UV spectrophotometric methods have been developed for the simultaneous determination of atorvastatin calcium (ATV) and olmesartan medoxomil (OLM) in a pharmaceutical formulation. The RP-HPLC separation was achieved on a Kromasil C18 column (250 × 4.6 mm, 5 μm particle size) using 0.01 M potassium dihydrogen o-phosphate (pH 4 adjusted with o-phosphoric acid)–acetonitrile (50 + 50, v/v) as the mobile phase at a flow rate of 1.5 mL/min. Quantification was achieved by UV detection at 276 nm. The HPTLC separation was achieved on precoated silica gel 60F254 plates using chloroform–methanol–acetonitrile (4 + 2 + 4, v/v/v) mobile phase. Quantification was achieved with UV detection at 276 nm. The UV-Vis spectrophotometric method was based on the simultaneous equation method that involves measurement of absorbance at two wavelengths, i. e., 255 nm (λmax of OLM) and 246.2 nm (λmax of ATV) in methanol. All three methods were validated as per International Conference on Harmonization guidelines. The proposed methods were simple, precise, accurate, and applicable for the simultaneous determination of ATV and OLM in a marketed formulation. The results obtained by applying the proposed methods were statistically analyzed and were found satisfactory.


Sign in / Sign up

Export Citation Format

Share Document