scholarly journals Flow Regime Maps of Large Particle-Water Two-phase Flow in a Vertical Pipe.

1996 ◽  
Vol 10 (4) ◽  
pp. 397-404
Author(s):  
Tadashi SAKAGUCHI ◽  
Li DANG ◽  
Yukio MISUGI ◽  
Yoshio KAJIHARA ◽  
Takahiro YAMASITA
1994 ◽  
Vol 59 (12) ◽  
pp. 2595-2603
Author(s):  
Lothar Ebner ◽  
Marie Fialová

Two regions of instabilities in horizontal two-phase flow were detected. The first was found in the transition from slug to annular flow, the second between stratified and slug flow. The existence of oscillations between the slug and annular flows can explain the differences in the limitation of the slug flow in flow regime maps proposed by different authors. Coexistence of these two regimes is similar to bistable behaviour of some differential equation solutions.


2015 ◽  
Vol 2015 ◽  
pp. 1-14 ◽  
Author(s):  
Viet-Anh Phung ◽  
Pavel Kudinov ◽  
Dmitry Grishchenko ◽  
Martin Rohde

RELAP5 is a system thermal-hydraulic code that is used to perform safety analysis on nuclear reactors. Since the code is based on steady state, two-phase flow regime maps, there is a concern that RELAP5 may provide significant errors for rapid transient conditions. In this work, the capability of RELAP5 code to predict the oscillatory behavior of a natural circulation driven, two-phase flow at low pressure is investigated. The simulations are compared with a series of experiments that were performed in the CIRCUS-IV facility at the Delft University of Technology. For this purpose, we developed a procedure for calibration of the input and code validation. The procedure employs (i) multiple parameters measured in different regimes, (ii) independent consideration of the subsections of the loop, and (iii) assessment of importance of the uncertain input parameters. We found that predicted system parameters are less sensitive to variations of the uncertain input and boundary conditions in high frequency oscillations regime. It is shown that calculation results overlap experimental values, except for the high frequency oscillations regime where the maximum inlet flow rate was overestimated. This finding agrees with the idea that steady state, two-phase flow regime maps might be one of the possible reasons for the discrepancy in case of rapid transients in two-phase systems.


2004 ◽  
Vol 126 (1) ◽  
pp. 107-118 ◽  
Author(s):  
J. L. Pawloski ◽  
C. Y. Ching ◽  
M. Shoukri

The void fractions, flow regimes, and pressure drop of air-oil two-phase flow in a half-inch diameter pipe over a wide range of test conditions have been investigated. The flow regimes were identified with the aid of a 1000 frames per second high-speed camera. A capacitance sensor for instantaneous void fraction measurements was developed. The mean and probability density function of the instantaneous void fraction signal can be used to effectively identify the different flow regimes. The current flow regime data show significant differences in the transitional boundaries of the existing flow regime maps. Property correction factors for the flow regime maps are recommended. The pressure drop measurements were compared to the predictions from four existing two-phase flow pressure drop models. Though some of the models performed better for certain flow regimes, none of the models were found to give accurate results over the entire range of flow regimes.


2003 ◽  
Vol 125 (4) ◽  
pp. 544-544 ◽  
Author(s):  
Sang Young Son ◽  
Jeffrey S. Allen ◽  
Kenneth O. Kihm

2011 ◽  
Vol 32 (1) ◽  
pp. 164-175 ◽  
Author(s):  
J. Enrique Julia ◽  
Basar Ozar ◽  
Jae-Jun Jeong ◽  
Takashi Hibiki ◽  
Mamoru Ishii

Sign in / Sign up

Export Citation Format

Share Document