Numerical Study of Discharged Heat Water Effect on Aquatic Environment From Coastal Thermal Power Plant by Using Two Water Discharged Pipes

2018 ◽  
Vol 7 (2) ◽  
pp. 97-116
Author(s):  
Alibek Issakhov

The article presents a numerical study of the thermal load on the aquatic environment by using two water discharge pipes under various operational capacities of thermal power plant. It is solved by the Navier-Stokes and temperature transport equations for an incompressible fluid in a stratified medium. The aim of this article is to improve the existing water discharge system for reduce the heat load on the reservoir-cooler of the thermal power plants operation (Ekibastuz SDPP-1). In this article, thermal pollution using only two water discharge pipes, using the existing one and building only one additional in the eastern part of the reservoir-cooler is numerically simulated. The numerical method is based on the projection method, which was approximated by the finite volume method. The obtained numerical results of three-dimensional stratified turbulent flow for two water discharge pipes under various operational capacities of the thermal power plant were compared with experimental data and with the numerical results for one water discharge pipe.

Author(s):  
Alibek Issakhov

AbstractThe paper presents a numerical study of the discharged heat water effect on the aquatic environment from the thermal power plant by using two water discharged pipes. It is solved by the Navier–Stokes and temperature transport equations for an incompressible fluid in a stratified medium. The aim of this study is to improve the existing water discharge system to reduce the heat load on the reservoir-cooler of the thermal power plants operation (Ekibastuz SDPP-1). In this study thermal pollution to the reservoir-cooler using only two water discharged pipes as so using the existing one and building only one additional in the eastern part of the reservoir-cooler is numerically simulated. The numerical method is based on the projection method which was approximated by the finite volume method. The numerical solution of the equation system is divided into four stages. The algorithm is parallelized on a high-performance computer. The obtained numerical results of three-dimensional stratified turbulent flow for two water discharged pipes of the thermal power plant were compared with experimental data and with numerical results for one water discharged pipe. General thermal load in the reservoir-cooler decreases comparing one water discharged pipe and revealed qualitatively and quantitatively approximately the basic laws of hydrothermal processes occurring in the reservoir-cooler can be seen that from numerical simulations where two water discharged pipes were used.


2012 ◽  
Vol 58 (4) ◽  
pp. 351-356
Author(s):  
Mincho B. Hadjiski ◽  
Lyubka A. Doukovska ◽  
Stefan L. Kojnov

Abstract Present paper considers nonlinear trend analysis for diagnostics and predictive maintenance. The subject is a device from Maritsa East 2 thermal power plant a mill fan. The choice of the given power plant is not occasional. This is the largest thermal power plant on the Balkan Peninsula. Mill fans are main part of the fuel preparation in the coal fired power plants. The possibility to predict eventual damages or wear out without switching off the device is significant for providing faultless and reliable work avoiding the losses caused by planned maintenance. This paper addresses the needs of the Maritsa East 2 Complex aiming to improve the ecological parameters of the electro energy production process.


Author(s):  
Ye. G. Polenok ◽  
S. A. Mun ◽  
L. A. Gordeeva ◽  
A. A. Glushkov ◽  
M. V. Kostyanko ◽  
...  

Introduction.Coal dust and coal fi ring products contain large amounts of carcinogenic chemicals (specifically benz[a]pyrene) that are different in influence on workers of coal mines and thermal power plants. Specific immune reactions to benz[a]pyrene therefore in these categories of workers can have specific features.Objective.To reveal features of antibodies specifi c to benz[a]pyrene formation in workers of coal mines and thermal power plants.Materials and methods.The study covered A and G class antibodies against benz[a]pyrene (IgA-Bp and IgG-Bp) in serum of 705 males: 213 donors of Kemerovo blood transfusion center (group 1, reference); 293 miners(group 2) and 199 thermal power plant workers (group 3). Benz[a]pyrene conjugate with bovine serum albumin as an adsorbed antigen was subjected to immune-enzyme assay.Results.IgA-Bp levels in the miners (Me = 2.7) did not differ from those in the reference group (Me = 2.9), but in the thermal power plant workers (Me = 3.7) were reliably higher than those in healthy men and in the miners (p<0.0001). Levels of IgG-Bp in the miners (Me = 5.0) appeared to be lower than those in the reference group (Me = 6.4; (p = 0.05). IgG-Bb level in the thermal power plantworkers (Me = 7.4) exceeded the parameters in the healthy donors and the miners (p<0.0001). Non-industrial factors (age and smoking) appeared tohave no influence on specific immune reactions against benz[a]pyrene in the miners and the thermal power plant workers.Conclusions.Specific immune reactions against benz[a]pyrene in the miners and the thermal power plant workers are characterized by peculiarities: the miners demonstrate lower levels of class A serum antibodies to benz[a]pyrene; the thermal power plant workers present increased serum levels of class G antibodies to benz[a]pyrene. These peculiarities result from only the occupational features, but do not depend on such factors as age, smoking and length of service at hazardous production. It is expedient to study specific immune reactions to benz[a]pyrene in workers of coal mines and thermal power plants, to evaluate individual oncologic risk and if malignancies occur.


Author(s):  
Kajori Parial ◽  
S. Mukherjee ◽  
A. R. Ghosh ◽  
D. Sengupta

Coal combustion in thermal power plants releases ash. Ash is reported to cause different adverse health hazards in humans and other organisms. Owing to the presence of radionuclides, it is also considered as a potential radiation hazard. In this study, based on the surface radiation measurements and relevant ancillary data, expected radiation risk zones were identified with regard to the human population residing near the Thermal Power Plant. With population density as the risk determining criteria, about 20% of the study area was at &lsquo;High&rsquo; risk and another 20% of the study area was at &lsquo;Low&rsquo; risk zone. The remaining 60% was under medium risk zone. Based on the findings remedial measures which may be adopted have been suggested.


Akustika ◽  
2021 ◽  
pp. 133-137
Author(s):  
Vladimir Tupov ◽  
Vitaliy Skvortsov

The power equipment of thermal power plants is a source of noise to the surrounding area. One of the sources of noise for the surrounding area are gas distribution points (GDP) of thermal power plants (TPP) and district thermal power plants (RTS). Noise from gas distribution points may exceed sanitary standards at the border of the sanitary protection zone. The article shows that the radiated noise from gas distribution points depends on the power of the thermal power plant (natural gas consumption) and the type of valves. Three types of valves used in gas distribution points are considered. Formulas are obtained for calculating the width of the sanitary protection zone for gas distribution points for thermal stations, depending on the consumption of natural gas (electric power of the thermal power plant) and the type of valve. It is shown that, depending on the valve used, the noise level at the border of the sanitary protection zone can either meet sanitary standards or exceed them. This allows at the design stage to select the required type of valve or to determine mitigation measures from hydraulic fracturing.


Author(s):  
Suchismita Satapathy

All companies are dependent on their raw material providers. The same applies in the case of thermal power plants. The major raw material for a thermal power plant is the coal. There are a lot of companies which in turn provide this coal to the thermal power plant. Some of these companies are international; some are local, whereas the others are localized. The thermal power plants look into all the aspects of the coal providing company, before settling down for a deal. Some people are specifically assigned to the task of managing the supply chain. The main motive is to optimize the whole process and achieve higher efficiency. There are a lot of things which a thermal power plant looks into before finalizing a deal, such as the price, quality of goods, etc. Thus, it is very important for the raw material providers to understand each and every aspect of the demands of the thermal power plant. A combination of three methods—Delphi, SWARA, and modified SWARA—has been applied to a list of factors, which has later been ranked according to the weight and other relevant calculations.