scholarly journals Fluoroless Catheter Ablation of Atrial Fibrillation: Integration of Intracardiac Echocardiography and Cartosound Module

2021 ◽  
Vol 14 (2) ◽  
Author(s):  
Alfredo Pantano
EP Europace ◽  
2012 ◽  
Vol 15 (1) ◽  
pp. 24-32 ◽  
Author(s):  
Bashar Aldhoon ◽  
Dan Wichterle ◽  
Petr Peichl ◽  
Robert Čihák ◽  
Josef Kautzner

2009 ◽  
Vol 18 ◽  
pp. S166
Author(s):  
S. Townsend ◽  
N. Wessel ◽  
G. Scalia ◽  
K. Phillips

2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Fei Hang ◽  
Liting Cheng ◽  
Zhuo Liang ◽  
Ruiqing Dong ◽  
Xinlu Wang ◽  
...  

Aims. 3D electroanatomical mapping combined with intracardiac echocardiography- (EAM-ICE-) guided transseptal puncture has been proven safe and effective during the radiofrequency catheter ablation (RFCA) procedure used to treat paroxysmal atrial fibrillation (PAF). In this study, we aimed to compare the curative effect and safety of RFCA via F (fluoroscopy) and zero-fluoroscopy transseptal puncture guided by EAM-ICE in patients with PAF. Methods and Results. A prospective study in which 110 patients with PAF were included and assigned to two groups was conducted. Fifty-five (50%) patients were enrolled in the EAM-ICE group, whereas the other 55 (50%) patients were enrolled in the F group. There were no significant differences in baseline characteristics between the two groups. The transseptal duration time was longer in the EAM-ICE group (19.8 ± 3.0 min vs. 8.6 ± 1.2 min, p ≤ 0.01 ); however, fluoroscopy was not used in the EAM-ICE group compared with the F group (0 mGy vs. 109.1 ± 57.9 mGy). Similarly, there was also no significant difference in the recurrence rate of atrial fibrillation between the EAM-ICE and F groups (25.5% vs. 18.2%, p = 0.356 ). Conclusion. RFCA via EAM-ICE-guided zero-fluoroscopy transseptal puncture in patients with PAF is safe and effective for long-term follow-up.


2021 ◽  
Author(s):  
Ioan-Alexandru Minciuna ◽  
Mihai Puiu ◽  
Gabriel Cismaru ◽  
Radu Roșu ◽  
Raluca Tomoaia ◽  
...  

Aims: Intracardiac echocardiography (ICE) is a relatively young technique used during complex electrophysiology proce-dures, such as atrial fibrillation (AF) ablation. The aim of this study was to assess whether the use of ICE modifies the radia-tion exposure at the beginning of the learning curve in AF ablation. Materials and methods: In this retrospective study, 52 patients, in which catheter ablation for paroxysmal or persistent AF was performed, were included. For 26 patients we used ICE guidance together with fluoroscopy, whereas for the remaining 26 patients we used fluoroscopy alone, all supported by electroanatomical mapping. We compared total procedure time and radiation exposure, including fluoroscopy dose and time between the two groups and along the learning curve. Results: Most of the patients included were suffering from paroxysmal AF (40, 76%), pulmonary vein isolation being performed in all patients, without secondary ablation sites. The use of ICE was associated with a lower fluoroscopy dose (11839.60±6100.6 vs. 16260.43±8264.5 mGy, p=0.041) and time (28.00±12.5 vs. 42.93±12.7 minutes, p=0.001), whereas the mean procedure time was similar between the two groups (181.54±50.3 vs 197.31±49.8 minutes, p=0.348). Radiation exposure was lower in the last 9 months compared to the first 9 months of the study (p<0.01), decreasing gradually along the learning curve. Conclusions: The use of ICE lowers radiation exposure in AF catheter ablation from the beginning of the learning curve, without any difference in terms of acute safety or efficacy. Aware-ness towards closest to zero radiation exposure during electrophysiology procedures should increase in order to achieve better protection for both patient and medical staff.


Author(s):  
Carola Gianni ◽  
Javier E. Sanchez ◽  
Domenico G. Della Rocca ◽  
Amin Al-Ahmad ◽  
Rodney P. Horton ◽  
...  

EP Europace ◽  
2008 ◽  
Vol 10 (Supplement 3) ◽  
pp. iii42-iii47 ◽  
Author(s):  
W. Saliba ◽  
J. Thomas

Sign in / Sign up

Export Citation Format

Share Document