Optimization Design of Core Thickness of Exterior Frame and Core Hybrid Structures in High-Rise Buildings

2012 ◽  
Vol 166-169 ◽  
pp. 14-18
Author(s):  
Shu Yun Zhang ◽  
Wen Wei Zhao ◽  
Hai Hua Wang

Considering core thickness is important issue to performance of exterior frame and core hybrid structure in high-rise buildings, seismic response analysis is conducted by response spectrum method for finite element models with different core thickness. The optimization design of core thickness of hybrid Structures on the basis of the seismic response is studied, the core thicknesses are chosen as design variables, the objective function about core volume is adopted, some specification requirements such as deformation, the ratio of lateral stiffness to gravity, storey shear to gravity, storey shear of exterior frame, axial compression ratio of column and wall limb, bearing capacity of structural member and core construction are regarded as restricting conditions, the optimal mathematical model is established for reflecting integrity dynamic properties of hybrid structure. The ANSYS software is used for optimizing tool, the hybrid structures optimization design are made through different initial values for verifying convergence of optimization method, the optimal result show that the performances of hybrid structure are improved, the internal forces are reduced and the ratios of inner force born by exterior frames are increased in the optimal scheme.

2021 ◽  
Vol 889 (1) ◽  
pp. 012045
Author(s):  
Mir Rahman Naseri ◽  
Balwinder Singh

Abstract A hybrid structure is one that combines more than two different types of materials to compensate for weak places while also maximizing strength. Hybrid steel and concrete frameworks, as well as other modern materials, are unified at the member or framework unit. Hybrid structures are frequent in high-rise and super-high-rise building projects, and they provide the benefit of cost savings. Shear walls are built to withstand lateral loadings like earthquakes and winds loads. The response spectrum analysis approach is frequently used to measure design stresses for earthquake-prone structures. The modelling and analysis of the regular plan structures are done by CSI ETABS 2019 in IV seismic zones, on type II (medium soil) of India According to IS 1893 (Part-1) 2016. The aims of this study Response spectrum analysis of 41 storey RCC and hybrid structures with shear walls and without shear walls are compared. RCC and hybrid structures with shear walls showed lower storey displacement, storey drift, and story shear values than RCC and hybrid structures without shear walls, according to the results of this study. The research results will be helpful as a reference and a tool for seismic analysis of hybrid structures.


2010 ◽  
Vol 163-167 ◽  
pp. 3964-3971
Author(s):  
Zhen Xuan Zhang ◽  
Qing Jun Chen

Based on seismic records with large long-period components at home and abroad, carried on uniform error correction processing and rough site classification, then, used numerical analysis software-MATLAB to calculate the average response spectrum of different types of venues, and used the least square method to do sub-fitting for them, got the long-period quasi-regulatory response spectrums of all kinds of venues; using the general-purpose finite element analysis software-ANSYS, a super high-rise building structural analysis model was established, inputted the fitted long-period seismic response spectrum and the design response spectrum of Shanghai anti-seismic standards, by comparing the results of structural seismic responeses under the two kinds of response spectrum, the long-period seismic response of super high-rise building was investigated, and some valuable conclusions were obtained for reference.


2014 ◽  
Vol 580-583 ◽  
pp. 1729-1733
Author(s):  
Ming Li ◽  
Yuan Qing Wang ◽  
Wei Tao ◽  
Bin Wang ◽  
Qing Xian Yu ◽  
...  

Rare study is done on floor response spectrum of super-high rise building, but it is an important condition for the seismic response analysis of floor subsidiary structure. Therefore, based on the early calculation model of China Financial Information Mansion, the floor response spectrum is calculated under different input ground motion. The floor and ground response spectrum is compared with each other from the seismic coefficient, dynamic amplification coefficient, characteristic period and the form of response spectrum. The results shows that: the floor seismic coefficient and the magnification coefficient are greater or smaller than the ground ones, the biggest difference of which is nearly 1 times; all the floor character period are greater than the ground ones, the biggest difference of which is over 60%; there are obvious differences between the floor and ground dynamic magnification factor spectra form under some conditions, of which the second peak of the former one is probably very large, even near to the peak of the first one, while the latter has no such phenomenon. Therefore, during the process of calculating the seismic response of floor subsidiary structure, it is necessary to consider the change of floor seismic coefficient, dynamic magnification factor, characteristic period and spectra form based on the main structure.


Sign in / Sign up

Export Citation Format

Share Document