An advanced experimental rig for heat pump water heaters was established. The performances of both a phase change heat-storage-type heat pump water heater (Type A) and a conventional heat pump water heater (Type B) were tested and compared according to GB/T 23137-2008 using the experimental rig. The results showed that the existence of phase transition temperature platform enabled the phase change heat-storage-type heat pump heater run longer and more steadily. When the same hot water heat capacity obtained, the volume of the accumulator in the Type A water heater accounted for about 56.9% of that of the water tank in the Type B water heater, which could save the overall size of water heater significantly and therefore promote the wide application of energy-saving heat pump water heaters.

2014 ◽  
Vol 521 ◽  
pp. 748-751
Author(s):  
Zhao Xia Zhou

A survey for water heater in urban residential buildings is carried in Wuhan. The results show that more than 40% subjects use solar energy water heat. More than 20% subjects point out the energy consumption of water heater should be decreased. There are about 24.8% subjects take initial cost as the first place when they chose water heater. 44.2% subjects know about heat pump water heater, but they could not buy it if the initial cost is too high. There are 84% subjects could select heat pump water heater when the cost is no more 20% high than the average price of the common water heaters. Moreover, the energy consumptions of residential water heaters are also investigated. The energy consumption characteristics of water heater in Wuhan are analyzed.


Author(s):  
Aaron K. Ball ◽  
Chip W. Ferguson ◽  
Frank T. Miceli ◽  
Evelyn Baskin

A new a dual-service dehumidifier water heater (WHD) appliance is being researched and developed by the authors. Prior research on a similar appliance, a heat pump water heater (HPWH), has demonstrated the unit’s increased performance and energy saving, and through collaboration, significant progress has been made toward developing the WHD into a potentially marketable product. The primary energy use in residential households is space conditioning (49%), and the second major energy use is hot water consumption. In DOE’s 2004 Buildings Data Book, 15.5 percent of residential energy utilization is consumed by water heating (DOE 2004, Table 1.2.3). The two major types of residential water heaters are direct gas fired (~55%) and electric resistance (~45%) (DOE 2004, Appliance Magazine 2005). The maximum efficiency of a standard electric resistance water heater is 1 (100%), and progress has been made to increase the efficiency of the current standard heaters to approximately 95 percent (DOE 2004, Table 5.10.6), which is roughly the maximum available with today’s technology. However, if the standard system is replaced by a Heat Pump Water Heater (HPWH), the performance can be increased by 140 percent (Zogg and Murphy 2004). The WHD operates as a HPWH while heating water and as a dedicated dehumidifier when water heating is not necessary. This paper presents the general design and laboratory testing results of a WHD. Preliminary performance data reveal coefficient of performances (COP) of approximately 2.2 during water heating. Further, market analysis has revealed that a potential need for this new technology is in regions with high humidity (Ashdown et al. 2004). These regions are primarily in the Northeast, Southeast and some coastal areas of the U.S. Current HPWH units do not have dedicated dehumidification and have a very small share of the residential water heat market. Of the 9.55 million residential water heaters sold in 2003 only about 2,000 of them were HPWHs (DOE 2004, Table 5.10.15).


2017 ◽  
Vol 206 ◽  
pp. 784-792 ◽  
Author(s):  
Deqiu Zou ◽  
Xianfeng Ma ◽  
Xiaoshi Liu ◽  
Pengjun Zheng ◽  
Baiming Cai ◽  
...  

2012 ◽  
Vol 512-515 ◽  
pp. 303-306
Author(s):  
Xue Lai Liu ◽  
Guan Zhu Wang ◽  
Yong An Li ◽  
Xiao Feng Zhang

This article describes the solar hot water system, and establishes the computational model of hot water system. It analyzes the economical efficiency of solar water heaters which equipped with electric water heaters, gas water heaters and air-source heat pump water heaters. The results show that the initial investment of the system which equipped with an electric water heater and a gas water heater is almost, but the operating cost which equipped with a gas water heater system is lower. The operating cost which equipped with an air-source heat pump water heater is the lowest, though the initial investment is the highest. The solar hot water system which equipped with an air-source heat pump water heater has important reference value for going low-carbon economy road in China.


Author(s):  
Leon Liebenberg ◽  
Josua P. Meyer

A high temperature electrically-operated heat pump water heater is evaluated in terms of the viability of employing capacity control using non-azeotropic refrigerant mixtures (NARMs). The system coefficient of performance (COP) is improved by introducing capacity control, which offers continuous modulation by varying heat pump capacity to match the load. This is accomplished by using a non-azeotropic refrigerant mixture (NARM) and changing the composition (x) of the circulating mixture. The NARM R-22/ R-142b is selected due to the requirement for a high condensing temperature and a wide capacity range. The life-cycle cost effectiveness of this heat pump is compared with that of a conventional heat pump (operating a pure fluid). Computer simulations show that the capacity-controlled heat pump, operating between compositions of 100% R-22 and 70% R-22, shows a 29.6% improvement in energy conversion when compared with a conventional R-22 heat pump water heater. The payback periods of the capacity-controlled systems, are strongly dependent on electricity tariff, additional system cost, and period and duration of heat pump operation.