Dielectric Study of Electron Capture Centers in Sillenite Crystals Bi12SiO20

2016 ◽  
Vol 835 ◽  
pp. 20-26
Author(s):  
Aleksandr Valentinovich Ilinskii ◽  
Rene Alejandro Castro ◽  
Liliya Ansafovna Nabiullina ◽  
Marina Ernstovna Pashkevich ◽  
Evgenii Borisovich Shadrin

The quantitative analysis of experimental results of research thermostimulated currents in crystals Bi12SiO20 (BSO) is lead carried out. Parameters of the capture centers in crystals BSO are determined.

1969 ◽  
Vol 52 (6) ◽  
pp. 1200-1202
Author(s):  
S W Gunner ◽  
R C O’Brien

Abstract CIIA is reacted with picryl chloride to form a stable crystalline N-trinitrophenyl derivative. This procedure eliminates CHA loss during sample work-up and, using GLC, permits detection in the subnanogram range with an electron capture detector. Quantitative analysis is achieved using 3,3,5-trimethylcyclohexylamine as internal standard and is illustrated by the analysis of CHA in cyclamate at a level of 1 ppm.


2005 ◽  
Vol 02 (02) ◽  
pp. 101-111
Author(s):  
LI-BIAO TONG ◽  
WEN-JUN LU ◽  
XIN HONG ◽  
TAO MEI ◽  
KE-JUN XU

Quantitative analysis of wrist forces for robot grippers is an important issue for robot control and operation safety. An approach is proposed to deduce the wrist forces from distributed force sensors in the robot fingers. A multi-layer forward (MLF) neural network is designed to fuse the data from finger force sensors. The experimental results demonstrate that the maximum deducing error of the wrist forces is decreased to 4.8% from 18.7% comparing with previous sensor fusion methods.


2013 ◽  
Vol 462-463 ◽  
pp. 17-20
Author(s):  
Hua Juan Bai ◽  
Ji Hong Feng ◽  
Kai Xiang Li ◽  
Hao He

In this paper we build up a set of simple urinary sediment detection device which is composed of a biological microscope, focusing mechanism, and CCD camera. We apply this device in urinary sediment detection to verify its feasibility. In our experiment, the urinary sediment quality control diluted 200 times is dropped into quantitative analysis plate to detect on the device. We watch and count the number of red and white blood cells in 30 counting pools. Microscopic images are clear and the number of red and white blood cells in these images fluctuates around the average value. Experimental results show that our device is feasible in urinary sediment detection.


2010 ◽  
Vol 26-28 ◽  
pp. 1-4
Author(s):  
Guo Nian Yao ◽  
Jun Hu Wei ◽  
Hao Sun ◽  
Guo Ji Sun

In order to improve the measuring accuracy and efficiency of projectiles’ centroidal deviation, the working principle and the relevant calculation formulae based on three points method are described in detail, the main factors affecting precision are discussed and quantitative analysis on precision of the equipment is made. The measuring platform with automatic leveling and locating based on the arc locating and so on are put forward to reduce error. The experimental results show that the system can satisfy the requirement for measuring with high accuracy. The equipment plays a very important role in testing ordnance, especially for measuring regular projectiles.


Sign in / Sign up

Export Citation Format

Share Document