Nonlinear Analysis for Masonry under Monotonic and Low Cyclic Loading

2011 ◽  
Vol 94-96 ◽  
pp. 406-415 ◽  
Author(s):  
Yan Huang ◽  
Ming Hui Kan ◽  
Zi Fa Wang

Abstract: Confined masonry with tie columns and ring-beams was adopted during the reconstruction in the rural and suburban areas in Sichuan Province after the 2008 Wenchuan Earthquake. Based on the results of the sample tests of building material such as clay brick, cement mortar, steel and concrete in reconstruction and the analysis on the characteristics and features using Solid65 elements in ANSYS, the shear property of joints in masonry structures under different vertical load (σ∕fm) is numerically simulated. Comparing the experimental results with the numerical ones, the proposed values for the shear transfer coefficients for open and closed crack of Solid65 elements for simulating masonry structures are given. The seismic performance of confined masonry walls (strengthened by tie column and ring-beam, etc.) and unconfined masonry walls with different stress condition (σ∕fm) under low cyclic load are discussed. Results show that, under monotonic loading, confined masonry walls have better performance for displacement and load corresponding to the occurrence of the first crack as well as for the ultimate load and ductility, although the energy dissipating ability of unconfined walls under low cyclic loading increases with vertical load (σ∕fm) at low stress level. The results demonstrate that confined walls are greatly enhanced by strengthening measures such as tie column and ring-beams.

2020 ◽  
Vol 323 ◽  
pp. 02002
Author(s):  
Łukasz Drobiec ◽  
Wojciech Mazur ◽  
Tomasz Rybarczyk

Strut & Tie (S-T) models are used quite commonly for the analysis of reinforced concrete structures and in the calculation of masonry structures. Creating the S-T model of the confined masonry is slightly different from models of reinforced concrete or models of classic masonry structures. These models should take into account different stiffness of concrete and masonry. This article proposes a Strut & Tie model for the analysis of confined masonry. The results of calculations were compared with the results of tests of full scale masonry walls with and without opening. Good compliance of the calculation results of S-T models with the test results was obtained.


2017 ◽  
Vol 747 ◽  
pp. 594-603 ◽  
Author(s):  
Hu Xu ◽  
Hao Wu ◽  
Cristina Gentilini ◽  
Qi Wang Su ◽  
Shi Chun Zhao

In this study, confined masonry specimens with regular arranged openings are tested in order to study the influence of different enhancements of the columns on seismic failure modes. In particular, five brick masonry walls and three half-scale two-storey masonry structures are tested under quasi-static loads. The experimental results show that increasing column ratio improves the seismic behavior of the wall specimens to some extent, but an excessive reinforcement ratio of the columns decreases the ductility. The global failure mode of the two-storey masonry structures is modified by inserting iron wires in the mortar bed joints, improving the structural collapse resistant capacity effectively.


2008 ◽  
Vol 56 ◽  
pp. 601-608 ◽  
Author(s):  
Donato Zangani

Textile structures are extensively used in construction in forms of geotextiles. The retrofitting of existing masonry walls and soil structures is particularly important for earthquake protection of historic buildings and protection of earthworks against landslides. Unreinforced masonry structures are highly vulnerable because being originally designed mainly for gravity loads they often cannot withstand the dynamic horizontal loads in case of strong earthquakes. Soil structures, such as embankments, are subjected to landslides after heavy rainfalls or during earthquakes. Hence the necessity to develop efficient methods for the retrofitting of existing masonry buildings and earthworks and of related monitoring systems to possibly prevent the structural damage. To solve the above issues new multifunctional textile structures are being developed for application in construction for the retrofitting of masonry structures and earthworks, integrating a combination of different functions, including structural health monitoring.


2017 ◽  
Vol 20 (11) ◽  
pp. 1632-1643 ◽  
Author(s):  
Masoud Amouzadeh Tabrizi ◽  
Masoud Soltani

This article focuses on the experimental and analytical investigations of masonry walls surrounded by tie-elements under in-plane loads. The experimental results of an unconfined and a confined masonry wall, tested under reversed cyclic lateral loads, are presented. For numerical study, a micro-modeling strategy, using smeared-crack-based approach, is adopted. In order to validate the numerical approach, experimental test results and data obtained from the literature are used, and through a systematic parametric study, the influence of adjoining walls and number of tie-columns on the seismic behavior of confined masonry panels is numerically assessed and a simple but rational method for predicting the nonlinear behavior of these structures is proposed.


2016 ◽  
Vol 142 (2) ◽  
pp. 04015126 ◽  
Author(s):  
Joel Moreno-Herrera ◽  
Jorge Varela-Rivera ◽  
Luis Fernandez-Baqueiro

Sign in / Sign up

Export Citation Format

Share Document