Study on the Direct Current Control Method Based on the d-q Transformation

2012 ◽  
Vol 588-589 ◽  
pp. 446-449
Author(s):  
Cong Mei Zha ◽  
Qi Ying Xu ◽  
Yong Sheng Zhu

Static var generator (SVG) basic principle and control method are introduced in the article, a direct current control method for SVG is put forward based on d-q transformation, this method is also analyzed from theory and made simulation model, the simulation results show that this control method is reasonable and effective.

2014 ◽  
Vol 556-562 ◽  
pp. 1789-1793
Author(s):  
Cong Mei Zha ◽  
Jia Yun Xu

In this paper ,a main circuit mathematical model of Advanced Static Var Generator (ASVG) is established. a direct current control method for SVG is put forward based on d-q transformation, this method is also analyzed from theory and made simulation model, the simulation results show that this control method is reasonable and effective.


2013 ◽  
Vol 694-697 ◽  
pp. 826-829
Author(s):  
Yan Han ◽  
Xiaoming Zhang ◽  
Pan Pan Yang

This Paper Briefly Describes the Basic Principle of Reactive Power Compensation and Introduces the Indirect Current Control and Direct Current Control Method Based on Instantaneous Reactive Power Theory. Compare the Two Control Theory and Use the MATABLE Simulink Environment to Analyzing the Difference between the Two Methods


Author(s):  
Akshay Kadu

This paper presents an application of reduced switch multilevel inverter topology to STACOM. This topology consists of basic unit in which two switches are connected in series and one H-bridge unit. Multilevel inverter is beneficial in terms of reliability and improved output quality. Multilevel inverter have only drawback of higher number of switches. This reduced switch topology has less number of switches as compared to conventional Cascaded H Bridge Inverter. Compared to direct control method, indirect control method is simple but due to fast response and precise control, direct current control method is quite effective. In this work STACOM is implemented to improve the Power factor of the power system. An extensive digital simulation of the recommended STATCOM and its controller is carried out using MATLAB/SIMULINK software to study system performance. Simulation results prove that using Direct current control technique overall power factor is improved.


2013 ◽  
Vol 397-400 ◽  
pp. 1901-1905
Author(s):  
Yu Feng Wang ◽  
Guang Ye Liu ◽  
Xiao Guo Lv ◽  
Zhong Chu Wang

In order to restrain harmonic pollution of power grid, the structure and control strategy of APF was researched. The structural parameters and method of direct current control of the most widely used APF with three-phase VSI was discussed. Decoupling control of active and reactive current on the dq plane was realized by dq transforming. Harmonic of load current was detected by Ip-Iq algorithm based on the instantaneous reactive power theory. Double closed-loop control was applied and PWM drive signals of IGBT were got through comparison of triangle wave and modulation wave. The simulation results demonstrate that the kind of control method make APF good dynamic response and static compensation.


2012 ◽  
Vol 588-589 ◽  
pp. 433-437 ◽  
Author(s):  
Ying Zhao ◽  
Jin Shan Ji ◽  
Nai Cheng Du

This paper mainly describes the mechanism and elimination method of harmonic in low-voltage power grid. Improve direct current control method in the traditional filter method,filtering the harmonic and timely compensating reactive power in the grid. On this condition, it can make the power grid safe and stability. At the same time simulate the improved direct current control method, and the results verify the correctness and rationality of the control method.


Sign in / Sign up

Export Citation Format

Share Document