scholarly journals Wavefront analysis and modulation transfer function of three multifocal intraocular lenses

2010 ◽  
Vol 58 (2) ◽  
pp. 109 ◽  
Author(s):  
MarconyR Santhiago ◽  
MarceloV Netto ◽  
Jackson Barreto ◽  
BeatrizAF Gomes ◽  
Arthur Schaefer ◽  
...  
2019 ◽  
Vol 30 (2) ◽  
pp. 299-306 ◽  
Author(s):  
Irene Altemir-Gomez ◽  
Maria S Millan ◽  
Fidel Vega ◽  
Francisco Bartol-Puyal ◽  
Galadriel Gimenez-Calvo ◽  
...  

Objective: To compare visual quality in patients implanted with Tecnis® monofocal (ZCB00) and multifocal (ZMB00) intraocular lenses taking into account their optical quality measured in vitro with an eye model. Methods: In total, 122 patients participated in this study: 44 implanted with monofocal and 78 with multifocal intraocular lenses. Measurements of visual acuity and contrast sensitivity were performed. The optical quality of the intraocular lenses was evaluated in three image planes (distance, intermediate and near) using an eye model on a test bench. The metric considered was the area under the curve of the modulation transfer function. Results: Optical quality at the far focus of the monofocal intraocular lens (area under the curve of the modulation transfer function = 66.97) was considerably better than that with the multifocal lens (area under the curve of the modulation transfer function = 32.54). However, no significant differences were observed between groups at the distance-corrected visual acuity. Distance-corrected near vision was better in the multifocal (0.15 ± 0.20 logMAR) than that in the monofocal group (0.43 ± 0.21 logMAR, p < 0.001), which correlated with the better optical quality at near reached by the multifocal intraocular lens (area under the curve of the modulation transfer function = 29.11) in comparison with the monofocal intraocular lens (area under the curve of the modulation transfer function = 5.0). In intermediate vision, visual acuity was 0.28 ± 0.16 logMAR (multifocal) and 0.36 ± 0.14 logMAR (monofocal) with p = 0.014, also in good agreement with the values measured in the optical quality (area under the curve of the modulation transfer function = 10.69 (multifocal) and 8.86 (monofocal)). The contrast sensitivity was similar in almost all frequencies. Pelli–Robson was slightly better in the monofocal (1.73) than in the multifocal group (1.64; p = 0.023). Conclusion: Patients implanted with multifocal ZMB00 achieved a distance visual acuity similar to those implanted with monofocal ZCB00, but showed significantly better intermediate and near visual acuity. A correlation was found between intraocular lenses’ optical quality and patients’ visual acuity. Contrast sensitivity was very similar between the multifocal and monofocal groups.


2009 ◽  
Vol 35 (4) ◽  
pp. 747-752 ◽  
Author(s):  
José M. Artigas ◽  
Cristina Peris ◽  
Adelina Felipe ◽  
José L. Menezo ◽  
Isaias Sánchez-Cortina ◽  
...  

2020 ◽  
pp. 112067212092684
Author(s):  
Javier Ruiz-Alcocer ◽  
Amalia Lorente-Velázquez ◽  
Pablo de Gracia ◽  
David Madrid-Costa

Background: The aim was to assess the impact of 5- and 10-degree rotations in the optical quality of a trifocal toric intraocular lens with different amounts of cylinder. Methods: Two Physiol Toric intraocular lenses with 1.5 and 3.0 D of cylinder were analysed in three different positions: centred, 5 and 10 degrees rotated. The optical quality of the intraocular lenses was evaluated with the PMTF optical bench through specific perpendicular targets. The analysis was performed by the through-focus modulation transfer function curves and the modulation transfer function corresponding to distance vision (0 D of vergence). Results: For a centred situation, the through-focus modulation transfer function curves of both intraocular lenses showed the classical three peaks corresponding to the powers of the two principal meridians of the intraocular lenses. When 5 and 10 degrees of rotation were induced, the three peaks were attenuated in both cases. The case with the intraocular lens with 3.0 D of cylinder and 10 degrees of rotation showed the worst optical quality and a significant loss of trifocality. The modulation transfer function values obtained for distance vision also showed the worst optical quality for the intraocular lens with 3.0 D of cylinder and 10 degrees of rotation. Conclusion: Rotations over 5 degrees decreased the optical quality of trifocal toric intraocular lenses, being this reduction moderate from 5 to 10 degrees for low levels of cylinder (≤1.5 D). For mid-high levels of cylinder (≥3.0 D), rotations over 5 degrees cause a significant loss of optical quality at all object distances.


2013 ◽  
Vol 42 (3) ◽  
pp. 271-276 ◽  
Author(s):  
Javier Ruiz-Alcocer ◽  
David Madrid-Costa ◽  
Santiago García-Lázaro ◽  
Teresa Ferrer-Blasco ◽  
Robert Montés-Micó

2020 ◽  
Vol 238 ◽  
pp. 12005
Author(s):  
Jesús Armengol ◽  
Nuria Garzón ◽  
Fidel Vega ◽  
Irene Altemir ◽  
María S. Millán

The optical quality of three multifocal intraocular lenses (MIOLs) was measured in vitro using the area under the modulation transfer function (MTFa) and energy efficiency (EE). We evaluated those metrics through-focus (TF) by axially scanning the image space with three wavelengths (R, G, B). High linear correlation between MTFa and EE was found for all cases. Correlations between optical in vitro results (polychromatic TF-MTFa and TF-EE) and clinical visual acuity (VA) defocus curves for the three MIOLs allowed us to derive mathematical expressions. Both metrics proved to be equivalent to predict postoperative VA.


Sign in / Sign up

Export Citation Format

Share Document