scholarly journals Comparison of visual and optical quality of monofocal versus multifocal intraocular lenses

2019 ◽  
Vol 30 (2) ◽  
pp. 299-306 ◽  
Author(s):  
Irene Altemir-Gomez ◽  
Maria S Millan ◽  
Fidel Vega ◽  
Francisco Bartol-Puyal ◽  
Galadriel Gimenez-Calvo ◽  
...  

Objective: To compare visual quality in patients implanted with Tecnis® monofocal (ZCB00) and multifocal (ZMB00) intraocular lenses taking into account their optical quality measured in vitro with an eye model. Methods: In total, 122 patients participated in this study: 44 implanted with monofocal and 78 with multifocal intraocular lenses. Measurements of visual acuity and contrast sensitivity were performed. The optical quality of the intraocular lenses was evaluated in three image planes (distance, intermediate and near) using an eye model on a test bench. The metric considered was the area under the curve of the modulation transfer function. Results: Optical quality at the far focus of the monofocal intraocular lens (area under the curve of the modulation transfer function = 66.97) was considerably better than that with the multifocal lens (area under the curve of the modulation transfer function = 32.54). However, no significant differences were observed between groups at the distance-corrected visual acuity. Distance-corrected near vision was better in the multifocal (0.15 ± 0.20 logMAR) than that in the monofocal group (0.43 ± 0.21 logMAR, p < 0.001), which correlated with the better optical quality at near reached by the multifocal intraocular lens (area under the curve of the modulation transfer function = 29.11) in comparison with the monofocal intraocular lens (area under the curve of the modulation transfer function = 5.0). In intermediate vision, visual acuity was 0.28 ± 0.16 logMAR (multifocal) and 0.36 ± 0.14 logMAR (monofocal) with p = 0.014, also in good agreement with the values measured in the optical quality (area under the curve of the modulation transfer function = 10.69 (multifocal) and 8.86 (monofocal)). The contrast sensitivity was similar in almost all frequencies. Pelli–Robson was slightly better in the monofocal (1.73) than in the multifocal group (1.64; p = 0.023). Conclusion: Patients implanted with multifocal ZMB00 achieved a distance visual acuity similar to those implanted with monofocal ZCB00, but showed significantly better intermediate and near visual acuity. A correlation was found between intraocular lenses’ optical quality and patients’ visual acuity. Contrast sensitivity was very similar between the multifocal and monofocal groups.

2020 ◽  
pp. 112067212092684
Author(s):  
Javier Ruiz-Alcocer ◽  
Amalia Lorente-Velázquez ◽  
Pablo de Gracia ◽  
David Madrid-Costa

Background: The aim was to assess the impact of 5- and 10-degree rotations in the optical quality of a trifocal toric intraocular lens with different amounts of cylinder. Methods: Two Physiol Toric intraocular lenses with 1.5 and 3.0 D of cylinder were analysed in three different positions: centred, 5 and 10 degrees rotated. The optical quality of the intraocular lenses was evaluated with the PMTF optical bench through specific perpendicular targets. The analysis was performed by the through-focus modulation transfer function curves and the modulation transfer function corresponding to distance vision (0 D of vergence). Results: For a centred situation, the through-focus modulation transfer function curves of both intraocular lenses showed the classical three peaks corresponding to the powers of the two principal meridians of the intraocular lenses. When 5 and 10 degrees of rotation were induced, the three peaks were attenuated in both cases. The case with the intraocular lens with 3.0 D of cylinder and 10 degrees of rotation showed the worst optical quality and a significant loss of trifocality. The modulation transfer function values obtained for distance vision also showed the worst optical quality for the intraocular lens with 3.0 D of cylinder and 10 degrees of rotation. Conclusion: Rotations over 5 degrees decreased the optical quality of trifocal toric intraocular lenses, being this reduction moderate from 5 to 10 degrees for low levels of cylinder (≤1.5 D). For mid-high levels of cylinder (≥3.0 D), rotations over 5 degrees cause a significant loss of optical quality at all object distances.


2020 ◽  
Vol 238 ◽  
pp. 12005
Author(s):  
Jesús Armengol ◽  
Nuria Garzón ◽  
Fidel Vega ◽  
Irene Altemir ◽  
María S. Millán

The optical quality of three multifocal intraocular lenses (MIOLs) was measured in vitro using the area under the modulation transfer function (MTFa) and energy efficiency (EE). We evaluated those metrics through-focus (TF) by axially scanning the image space with three wavelengths (R, G, B). High linear correlation between MTFa and EE was found for all cases. Correlations between optical in vitro results (polychromatic TF-MTFa and TF-EE) and clinical visual acuity (VA) defocus curves for the three MIOLs allowed us to derive mathematical expressions. Both metrics proved to be equivalent to predict postoperative VA.


2017 ◽  
Vol 28 (1) ◽  
pp. 36-41 ◽  
Author(s):  
Genís Cardona ◽  
Fidel Vega ◽  
Miguel A. Gil ◽  
Consuelo Varón ◽  
José A. Buil ◽  
...  

Purpose: To compare objective image quality at distant, intermediate, and near foci with the corresponding visual acuity (VA) in patients symmetrically implanted with 5 different diffractive multifocal intraocular lenses (IOLs) (ReSTOR SV25T0, Tecnis ZKB00, Tecnis ZLB00, AT LISA 809, and AT LISA Tri 839MP) and a monofocal lens (Tecnis ZA9003) 3 months after cataract intervention. Methods: Objective image quality, measured as the area under the modulation transfer function curve (AMTF), was tested in vitro in an eye model. In addition, corrected distance visual acuity and distance-corrected intermediate and near visual acuities (DCIVA and DCNVA) were assessed in a group of 79 patients, randomly implanted with one of the lenses. Results: Image quality and VA at the distant focus was good for all lens designs, but was similarly compromised at the intermediate focus, where the best DCIVA corresponded to the low add ZKB00. At the near focus, the monofocal lens and the distance dominant SV25T0 had the worst AMTF values, with the ZLB00 presenting the best DCNVA. The relationship between AMTF and VA was found not to be linear, with VA being similarly good for AMTF values over a certain threshold. Conclusions: Visual acuity of pseudophakic patients reflected the optical quality of the specific IOL design within a certain range of measurements, beyond which maximum VA is limited by other ocular, optical, and neuropsychophysical factors.


2014 ◽  
Vol 95 (4) ◽  
pp. 515-519
Author(s):  
K S Ivonin

Aim. To analyze the causes for patients’ dissatisfaction with the results of multifocal intraocular lens implantation. Methods. The research is based on the results of cataract surgeries in 220 patients (50 patients were implanted multifocal refractive intraocular «M-flex» lens, 40 - multifocal intraocular «Gradiol» lens, 64 - multifocal intraocular «Accord» lens, 66 - monofocal intraocular lens). Pre-and post-operative examination included visual acuity test (with and without correction to near, far and moderate distances), determination of the nearest point of clear vision, contrast sensitivity study using the «Zebra» software, stereo vision test, pupil diameter measuring, refractometry, keratometry, binocular vision color tests, patient questioning. Pre-operative evaluation was performed 1 day prior to surgery. Post-operative observation was carried out 1 week, 1, 3, 6 and 12 months after the surgery. Results. No statistically significant difference (p 0.05) in uncorrected visual acuity at different light intensity - 102 lux and 416 lux - was found between the groups with different types of multifocal intraocular lenses. In groups with multifocal intraocular lenses light side effects were observed in 46-52.5% of patients. However, there was no link between the light side effects and patients’ satisfaction with results of the surgery. Reduction of spatial contrast sensitivity parameters was registered in all groups of multifocal intraocular lenses patients compared to patients with monofocal intraocular lenses (p 0.05). According to the survey results, 92.5 to 94% of patients with multifocal intraocular lenses did not report decreased visual acuity on moderate distance. Conclusion. The most important reason for patients’ dissatisfaction with the results of the multifocal intraocular lenses implanting was the reduction of spatial-contrast sensitivity parameters. Bilateral multifocal intraocular lenses implanting improved the contrast ratio.


2010 ◽  
Vol 58 (2) ◽  
pp. 109 ◽  
Author(s):  
MarconyR Santhiago ◽  
MarceloV Netto ◽  
Jackson Barreto ◽  
BeatrizAF Gomes ◽  
Arthur Schaefer ◽  
...  

2011 ◽  
Vol 21 (6) ◽  
pp. 723-731 ◽  
Author(s):  
Gonzalo Muñoz ◽  
César Albarrán-Diego ◽  
Ma Ángeles Galotto ◽  
Javier Pascual ◽  
Teresa Ferrer-Blasco

Purpose. To determine whether implantation of acrylic intraocular lens (IOL) with aspheric design (Tecnis Z9003, AMO) results in improved visual acuity or contrast sensitivity compared with conventional spherical acrylic IOL (AR40e, AMO). Methods. In an intraindividual randomized prospective study of 60 patients with bilateral cataract, the Tecnis Z9003 IOL was compared with the AR40e IOL. Ocular aberrations for a 4.0-mm pupil and 6.0-mm pupil were measured with a Hartmann-Shack aberrometer. Quality of vision was measured using visual acuity and contrast sensitivity under mesopic and photopic conditions. Results. Eyes with the Tecnis Z9003 IOL had significantly less spherical aberration and greater Strehl ratio after surgery, showing a better optical quality in comparison with the standard spherical IOL. However, visual acuity and both mesopic and photopic contrast sensitivity were not significantly different between the groups. Conclusions. The significantly better optical quality achieved with the aspheric acrylic IOL design did not result in improved visual acuity or contrast sensitivity in comparison with a conventional spherical acrylic IOL.


2012 ◽  
Vol 38 (2) ◽  
pp. 215-220 ◽  
Author(s):  
Marcony R. Santhiago ◽  
Steven E. Wilson ◽  
Marcelo V. Netto ◽  
Ramon C. Ghanen ◽  
Mario Luis R. Monteiro ◽  
...  

2018 ◽  
Vol 28 (4) ◽  
pp. 419-424 ◽  
Author(s):  
Jorge L Alió ◽  
Ana B Plaza-Puche ◽  
Jorge L Alió del Barrio ◽  
Pedro Amat-Peral ◽  
Vicente Ortuño ◽  
...  

Purpose: To evaluate clinical and visual outcomes, quality of near vision, and intraocular optical quality of patients bilaterally implanted with a trifocal PanOptix intraocular lens. Methods: In this prospective consecutive case-series study, 52 eyes of 26 bilateral patients (mean age, 60.2 ± 7.4 years) were implanted with the AcrySof IQ Panoptix intraocular lens. Visual acuity, defocus curve, contrast sensitivity (Pelli-Robson test), near activity visual questionnaire, and internal aberrations with Osiris were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. The follow-up was 6 months after surgery. Results: Uncorrected, corrected distance, and uncorrected near visual acuities improved with the surgery (p ≤ 0.02). Distance corrected near visual acuity was 0.13 ± 0.10, 0.13 ± 0.13, and 0.13 ± 0.08 at 1, 3, and 6 months after surgery, respectively (p = 0.82). Distance corrected intermediate visual acuities were 0.09 ± 0.13, 0.13 ± 0.15, and 0.12 ± 0.12 at 1, 3, and 6 months, postoperatively. Binocular contrast sensitivity was 1.86 ± 0.15 Log Units. Defocus curve provided a visual acuity equal or better to 0.30 LogMAR between defocus levels of +0.50 to −3.00 D. The near activity visual questionnaire scores improved significantly with the surgery (p < 0.01). Conclusion: The AcrySof IQ Panoptix intraocular lens is able to restore visual function with an acceptable intermediate and near vision after cataract surgery with good contrast sensitivity and an improvement in the near activity visual questionnaire.


2018 ◽  
Vol 3 (1) ◽  
pp. e000139
Author(s):  
Lee Lenton

ObjectiveTo compare the performance of adults with multifocal intraocular lenses (MIOLs) in a realistic flight simulator with age-matched adults with monofocal intraocular lenses (IOLs).Methods and AnalysisTwenty-five adults ≥60 years with either bilateral MIOL or bilateral IOL implantation were enrolled. Visual function tests included visual acuity and contrast sensitivity under photopic and mesopic conditions, defocus curves and low luminance contrast sensitivity tests in the presence and absence of glare (Mesotest II), as well as halo size measurement using an app-based halometer (Aston halometer). Flight simulator performance was assessed in a fixed-based flight simulator (PS4.5). Subjects completed three simulated landing runs in both daytime and night-time conditions in a randomised order, including a series of visual tasks critical for safety.ResultsOf the 25 age-matched enrolled subjects, 13 had bilateral MIOLs and 12 had bilateral IOLs. Photopic and mesopic visual acuity or contrast sensitivity were not significantly different between the groups. Larger halo areas were seen in the MIOL group and Mesotest values were significantly worse in the MIOL group, both with and without glare. The defocus curves showed better uncorrected visual acuity at intermediate and near distances for the MIOL group. There were no significant differences regarding performance of the vision-related flight simulator tasks between both groups.ConclusionsThe performance of visually related flight simulator tasks was not significantly impaired in older adults with MIOLs compared with age-matched adults with monofocal IOLs. These findings suggest that MIOLs do not impair visual performance in a flight simulator.


Sign in / Sign up

Export Citation Format

Share Document