scholarly journals Evaluation of reverse torque values and failure loads of three different abutment designs with internal connections

2020 ◽  
Vol 17 (6) ◽  
pp. 439
Author(s):  
AzamSadat Mostafavi ◽  
Saied Nokar ◽  
Habib Hajimiragha ◽  
Leyla Sadighpour
Author(s):  
Arda Ozdiler ◽  
suleyman dayan ◽  
Burc Gencel ◽  
Gulbahar Isık-Ozkol

This in vitro study evaluated the influence of taper angles on the internal conical connections of implant systems and of the application of chlorhexidine gel as an antibacterial agent or a polyvinyl siloxane (PVS) sealant on the reverse torque values of abutment screws after dynamic loading. The current study tested four implant systems with different taper angles (5.4°, 12°, 45°, and 60°). Specimens were divided into three groups: control (neither chlorhexidine gel filled nor silicone sealed), 2% chlorhexidine gel-filled or silicone-sealed group, and group subjected to a dynamic load of 50 N at 1 Hz for 500,000 cycles prior to reverse torque measurements. Quantitative positive correlation was observed between the taper angle degree and the percentage of tightening torque loss. However, this correlation was significant only for the 60° connection groups except in the group in which a sealant was applied ( p = 0.013 for the control group, p = 0.007 for the chlorhexidine group). Percentages of decrease in the torque values of the specimens with silicone sealant application were significantly higher compared with both the control and chlorhexidine groups ( p = 0.001, p = 0.002, p = 0.001, and p = 0.002, respectively, according to the increasing taper angles); the percentage of decrease in torque values due to chlorhexidine application was statistically insignificant when compared with the control group. The application of gel-form chlorhexidine as an antibacterial agent does not significantly affect the stability of the implant–abutment connection under dynamic loads. PVS sealants may cause screw loosening under functional loads.


2019 ◽  
Vol 28 (9) ◽  
pp. 969-972
Author(s):  
Eric Hu ◽  
Anton Petrich ◽  
Glen Imamura ◽  
Christopher Hamlin

2013 ◽  
Vol 26 (4) ◽  
pp. 331-333 ◽  
Author(s):  
Costanza Micarelli ◽  
Luigi Canullo ◽  
Paolo Baldissara ◽  
Marco Clementini

2014 ◽  
Vol 112 (4) ◽  
pp. 824-827 ◽  
Author(s):  
Daiane Cerutti-Kopplin ◽  
Dimas João Rodrigues Neto ◽  
Accácio Lins do Valle ◽  
Jefferson Ricardo Pereira
Keyword(s):  

2008 ◽  
Vol 34 (6) ◽  
pp. 298-302 ◽  
Author(s):  
Marcelo Soeiro Corsini ◽  
Fátima N. Faraco ◽  
Alessandra A. Pereira Castro ◽  
Tatiana Onuma ◽  
Wilson R. Sendyk ◽  
...  

Abstract The aim of this study was to evaluate the effect of intermittent administration of human parathyroid hormone [rhPTH (1–34)] on the removal torque of implants placed in rabbit tibiae. Twenty male New Zealand rabbits were submitted to implant surgery. Each animal received one machined screw-type implant (3.75 mm diameter × 8 mm length) in the proximal metaphysis of the right tibia. The rabbits were then divided into 2 groups: the test group (n = 10) received 6 μg/kg of rhPTH (1–34) subcutaneously in the dorsal region 3 days a week, and the control group (n = 10) received placebo. Removal torque was performed at 28 and 56 days after implant placement for both groups. The mean removal torque values at 28 days were 37.0 ± 4.36 Ncm and 47.4 ± 6.77 Ncm for control and test groups respectively (P < .05). At 56 days the reverse torque was 45.8 ± 3.96 Ncm for the control group and 55.8 ± 2.86 Ncm for the test group, indicating that the removal torque was significantly higher in the test groups (P < .05). These results demonstrated that intermittent treatment with rhPTH (1–34) enhanced the removal torque of implants in rabbit tibiae.


2011 ◽  
Vol 20 (7) ◽  
pp. 503-509 ◽  
Author(s):  
Paul M. Cashman ◽  
Robert L. Schneider ◽  
Galen B. Schneider ◽  
Clark M. Stanford ◽  
James M. Clancy ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document