scholarly journals Percutaneous closure of an aortic prosthetic paravalvular leak with device in a patient presenting with heart failure

Heart Views ◽  
2015 ◽  
Vol 16 (2) ◽  
pp. 56 ◽  
Author(s):  
Altug Osken ◽  
Ercan Aydin ◽  
Ramazan Akdemir ◽  
Huseyin Gunduz
2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
G Sa Mendes ◽  
R Teles ◽  
J Neves ◽  
M Trabulo ◽  
M Almeida ◽  
...  

Abstract Aims Paravalvular leak (PVL) presents an incidence ranging from 2–17%. Open heart surgery is considered the standard treatment and there is no consensus regarding the role of percutaneous closure of non-endocarditis PVL. Methods Single-centre retrospective study including consecutive patients that had their PVL closed percutaneously or by surgery, after heart team agreement, between 2007 and 2018. The primary goal was to assess mortality and rehospitalizations. The secondary goals were: a) the technical success, defined as reduction in regurgitation [≥1 degree] and b) clinic and laboratorial improvement. Results Forty-eight patients were included (mean age of 66±13 years, 56% male), 12 submitted to percutaneous closure and 36 to surgery (74 vs 65 years, p=0,026, respectively), with similar gender distribution. 56% had an aortic PVL, with the remainder having a mitral leak, with no difference between groups. The indications were heart failure in 91% and haemolytic anaemia in 42%. A combination of both indications and NYHA heart failure functional class ≥ III were higher in percutaneous group. The severity of leak was comparable in both groups. Patients treated percutaneously had a significant higher rate of atrial fibrillation (92% vs 42%), COPD (33% vs 3%), peripheral artery disease (58% vs 22%) and higher EuroScore II (13,1% [7,1 - 19,0 CI 95%] vs 4,1 [2,9 - 6,5 CI 95%], p=0,003). There was no significant difference between groups with respect to all- cause mortality at 6 months, and to cardiovascular (CV) mortality and CV rehospitalization at 1-year follow-up. The technical success was lower in percutaneous group, but clinic and laboratorial results did not differ (table). Primary and secondary [(a) tecnical success (b) clinical and laboratorial improvements] endpoints of percutaneous vs surgery paravalvular leak closure Percutaneous PVL closure Surgical PVL Closure p-value Mortality @ 6 M 17% 25% p=1.000 CV Mortality @ 12 M 25% 31% p=1.000 Rehospitalization @ 12 M 18% 21% p=0.694 Technical success (a) 75% 97% p=0.043 NYHA improvement (b) 70% 71% p=0.171 Hb improvement (b) mean Δ: 1.2±1.1 g/dl mean Δ: 1.3±2.5 g/dl p=0.737 LDH reduction (b) mean Δ: −682±828 U/L mean Δ: −473±1215 U/L p=0.577 Conclusions In this high-risk population, clinical and laboratorial improvement was achieved by both methods. The percutaneous technique seems more appropriate for patients with higher risk, despite a lower technical success in the reduction of the severity of the leak.


2012 ◽  
Vol 65 (3) ◽  
pp. 287
Author(s):  
Manuel Carnero Alcázar ◽  
Luis Carlos Maroto Castellanos ◽  
José Enrique Rodríguez Hernández

2020 ◽  
Vol 4 (3) ◽  
pp. 1-6
Author(s):  
Reda Abuelatta ◽  
Lamiaa Khedr ◽  
Ibraheem AlHarbi ◽  
Hesham A Naeim

Abstract Background Haemolytic anaemia is a complication of paravalvular leak (PVL). The correlation between the size of the leak and the severity of haemolysis is unclear. Small leaks can cause severe haemolysis, whereas significant leaks may cause no haemolysis. Case summary We report the case of a 40-year-old male who underwent mechanical mitral and aortic valve replacement 20 years ago. In the last 3 years, the procedure was repeated three times due to infective endocarditis. He presented with severe shortness of breath. A transoesophageal echocardiogram with three-dimensional surgical view showed that both discs of the mechanical mitral valve opened sufficiently but a severe PVL had occurred at the 9–12 o’clock position. The location of the mitral valve was abnormal, the sewing ring was inserted high at the mid-interatrial septum. The mechanical aortic valve functioned well. Closure of the transcutaneous PVL was accomplished with two percutaneously implanted devices, leaving a small leak in between. After closure, he developed haemolytic anaemia (haemoglobin: 6 g/dL, lactate dehydrogenase: 1896 units/L, reticulocyte count: 4.6%). He then received 16 units of packed red blood cells. He developed acute kidney injury and was started on haemodialysis. We then installed two additional devices to completely close the mild residual leak and another device to resolve the bidirectional transseptal defect. After 2 days, his renal function returned to normal and anaemia improved (haemoglobin: 9.1 g/dL). Discussion Mild residual paravalvular leak can cause severe haemolytic anaemia that is correctable via percutaneous closure of the leak.


2013 ◽  
Vol 9 (1) ◽  
pp. E19-E22 ◽  
Author(s):  
Thomas J. Seery ◽  
Michael C. Slack

2018 ◽  
Vol 68 (02) ◽  
pp. 148-157
Author(s):  
Chun Yang ◽  
Yang Liu ◽  
Jiayou Tang ◽  
Ping Jin ◽  
Lanlan Li ◽  
...  

Abstract Objective Paravalvular leak (PVL) after valve replacement remains clinically challenging. Percutaneous closure is an effective therapy for patients with PVLs because reoperation is associated with high rates of morbidity and mortality. The purpose of this study was to retrospectively compare the clinical outcome of transcatheter closure and surgical repair in patients with a PVL. Methods From January 2000 to May 2016, 131 patients with PVL were treated at three major medical centers in China. Perioperative characteristics and outcomes of the procedure were reviewed. Results Sixty-eight (51.9%) patients with PVLs were treated with percutaneous transcatheter closure (group I). The procedure was successful in 67 (98%) with no hospital deaths. Sixty-three (48.1%) patients with PVLs had a reoperation (group II). Five of the surgical patients had a third open-heart operation for residual regurgitation, and one underwent successful percutaneous closure. Six patients died in the hospital postoperatively. All patients in group II but only 11 in group I needed perioperative blood transfusions. The procedural time and hospital stay after the procedure were significantly shorter in group I than in group II. At the 1-year follow-up, cardiac function improved by ≥ 1 New York Heart Association functional class in 55 (82%) patients in group I and in 39 (68%) patients in group II. Conclusions Transcatheter closure was shown to be a safe, effective therapeutic option in patients with PVL. It was associated with a lower hospital mortality rate, shorter procedural time, and fewer blood transfusions than surgical treatment in selected patients.


Author(s):  
Shazib Sagheer ◽  
Shane Prejean ◽  
Thomas Watts ◽  
Mark A. Law ◽  
Mustafa Iltimas Ahmed

2013 ◽  
Vol 95 (2) ◽  
pp. e45-e46
Author(s):  
Pietro Giorgio Malvindi ◽  
Giuseppe Maria Raffa ◽  
Antioco Cappai ◽  
Alessandro Barbone ◽  
Alessio Basciu ◽  
...  

2013 ◽  
Vol 81 (7) ◽  
pp. 1249-1252 ◽  
Author(s):  
Candice Y. Lee ◽  
Frederick S. Ling ◽  
Peter A. Knight

Sign in / Sign up

Export Citation Format

Share Document