scholarly journals Study to compare the effect of different registration methods on patient setup uncertainties in cone-beam computed tomography during volumetric modulated arc therapy for breast cancer patients

2018 ◽  
Vol 43 (4) ◽  
pp. 207 ◽  
Author(s):  
D Khanna ◽  
P Mohandass ◽  
TManoj Kumar ◽  
T Thiyagaraj ◽  
C Saravanan ◽  
...  
Cancers ◽  
2021 ◽  
Vol 13 (7) ◽  
pp. 1651
Author(s):  
Jason Joon Bock Lee ◽  
Ik Jae Lee ◽  
Yeonho Choi ◽  
Mi Jin Jeon ◽  
Il Hun Jung ◽  
...  

With the introduction of modern sophisticated radiotherapy (RT) techniques, the significance of accuracy has increased considerably. This study evaluated the necessity of pre-treatment and intra-fractional cone-beam computed tomography (CBCT) by analyzing inter- and intra-fractional CBCT images of breast cancer patients receiving RT. From 57 patients, 1206 pre-treatment CBCT and 1067 intra-fractional CBCT images were collected. Geometric movements of patients were measured quantitively in both inter- and intra-fractional CBCT, and changes in dosimetric parameters were evaluated in selected patients with extreme intra-fractional movement. For right-sided breast cancer patients, left-sided breast cancer patients treated using deep-inspiration breath hold (DIBH), and left-sided breast cancer patients treated using continuous positive airway pressure (CPAP), median inter-fractional deviations were 0.53 (range 0.06–2.98) cm, 0.66 (range 0.08–4.41) cm, and 0.69 (range 0.04–3.80) cm, and median intra-fractional deviations were 0.14 (range 0.00–0.62) cm, 0.23 (range 0.02–0.96) cm, and 0.24 (0.00–1.15) cm, respectively. Modified plans reflecting large changes in intra-fractional position in 10 selected cases revealed insufficient target coverage in seven cases and more than 20-fold increase in the volume of heart receiving at least 25 Gy in two cases. Intra-fractional verification, as well as pre-treatment verification, might be considered in patients using DIBH or CPAP.


2020 ◽  
Author(s):  
Ramaiah Vinay Kumar

Abstract Background: Automatic Cone-beam computed tomography (CBCT) based image matching for set-up verification is recommended as compared to 2-D match for post-operative local / loco-regional radiotherapy of breast cancer patients by Volumetric Modulated Arc Therapy (VMAT) technique. However, in supine position, off-midline peripheral body Clinical Target Volume (CTV) of unilateral breast cancer patients immobilized on Breast and Lung board of All-in-One (AIO) positioning systemmay necessitate augmented movement of couch in ‘x’ and ‘z’ axis thereby raising the risk of collusion of x-ray sources / detectors system with couch. Methods and Materials: VMAT was planned by a pair of partial arc for whole target volume for seven consecutive post-operative breast cancer patients (five post-mastectomy and two post-breast conservation patients). Tattoo based set-up by shift of treatment table in x-, y- and z-axis as determined by Treatment Planning System followed by X-rays with planar image acquisition and online 2-D imaging matching was performed for set-up verification. In-room 360°rotation of x-ray source and detector system of linear accelerator (linac) was performed before x-ray planar image acquisition. Results: Completion of 360°rotation in-room of x-ray source and detector system of linacaround the machine iso-centre was not possible in six out of seven patients due to possibility of collusion of gantry with contralateral side of the couch. Conclusion: Performing CBCT for generating 3D images for computed tomography (CT) reconstruction may not be practical for patient set-up verification of post-operative radiotherapy of unilateral breast cancer patients positioned supine on breast and lung board.


2021 ◽  
Author(s):  
Zuzanna Krawczyk ◽  
Robert Szmurlo ◽  
Pawel Zawadzki ◽  
Estera Kot ◽  
Jacek Starzynski ◽  
...  

2017 ◽  
Vol 35 (1) ◽  
Author(s):  
Giuseppe Carlo Iorio ◽  
Pierfrancesco Franco ◽  
Elena Gallio ◽  
Stefania Martini ◽  
Francesca Arcadipane ◽  
...  

2016 ◽  
Vol 47 (2) ◽  
pp. 160-170 ◽  
Author(s):  
Manthala Padannayil Noufal ◽  
Kallikuzhiyil Kochunny Abdullah ◽  
Puzhakal Niyas ◽  
Thekedath Sankran Sankaran ◽  
Plankudy Ragavan Sasindaran

Sign in / Sign up

Export Citation Format

Share Document