scholarly journals An observational study of post-operative Volumetric Modulated Arc Radiotherapy (VMAT) of breast cancer by immobilizing patients on All-in-one (AIOTM) solution Breast and Lung Board without usingthermoplastic mask: Risk of collusion of gantry with couch exists if acquisition of Cone-beam Computed Tomography (CBCT)is attempted for set-up verification.

2020 ◽  
Author(s):  
Ramaiah Vinay Kumar

Abstract Background: Automatic Cone-beam computed tomography (CBCT) based image matching for set-up verification is recommended as compared to 2-D match for post-operative local / loco-regional radiotherapy of breast cancer patients by Volumetric Modulated Arc Therapy (VMAT) technique. However, in supine position, off-midline peripheral body Clinical Target Volume (CTV) of unilateral breast cancer patients immobilized on Breast and Lung board of All-in-One (AIO) positioning systemmay necessitate augmented movement of couch in ‘x’ and ‘z’ axis thereby raising the risk of collusion of x-ray sources / detectors system with couch. Methods and Materials: VMAT was planned by a pair of partial arc for whole target volume for seven consecutive post-operative breast cancer patients (five post-mastectomy and two post-breast conservation patients). Tattoo based set-up by shift of treatment table in x-, y- and z-axis as determined by Treatment Planning System followed by X-rays with planar image acquisition and online 2-D imaging matching was performed for set-up verification. In-room 360°rotation of x-ray source and detector system of linear accelerator (linac) was performed before x-ray planar image acquisition. Results: Completion of 360°rotation in-room of x-ray source and detector system of linacaround the machine iso-centre was not possible in six out of seven patients due to possibility of collusion of gantry with contralateral side of the couch. Conclusion: Performing CBCT for generating 3D images for computed tomography (CT) reconstruction may not be practical for patient set-up verification of post-operative radiotherapy of unilateral breast cancer patients positioned supine on breast and lung board.

Cancers ◽  
2018 ◽  
Vol 10 (12) ◽  
pp. 511 ◽  
Author(s):  
Viktor Hlavac ◽  
Maria Kovacova ◽  
Katerina Elsnerova ◽  
Veronika Brynychova ◽  
Renata Kozevnikovova ◽  
...  

The aim of our study was to set up a panel for targeted sequencing of chemoresistance genes and the main transcription factors driving their expression and to evaluate their predictive and prognostic value in breast cancer patients. Coding and regulatory regions of 509 genes, selected from PharmGKB and Phenopedia, were sequenced using massive parallel sequencing in blood DNA from 105 breast cancer patients in the testing phase. In total, 18,245 variants were identified of which 2565 were novel variants (without rs number in dbSNP build 150) in the testing phase. Variants with major allele frequency over 0.05 were further prioritized for validation phase based on a newly developed decision tree. Using emerging in silico tools and pharmacogenomic databases for functional predictions and associations with response to cytotoxic therapy or disease-free survival of patients, 55 putative variants were identified and used for validation in 805 patients with clinical follow up using KASPTM technology. In conclusion, associations of rs2227291, rs2293194, and rs4376673 (located in ATP7A, KCNAB1, and DFFB genes, respectively) with response to neoadjuvant cytotoxic therapy and rs1801160 in DPYD with disease-free survival of patients treated with cytotoxic drugs were validated and should be further functionally characterized.


2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Jian Hu ◽  
Guang Han ◽  
Yu Lei ◽  
Ximing Xu ◽  
Wei Ge ◽  
...  

Introduction. This study is aimed at evaluating the dosimetric differences among target segmented planning (TSP), conventional 9-field intensity modulated radiation therapy (9FIMRT) planning, and volumetric modulated arc therapy (VMAT) planning for postmastectomy radiotherapy of left-sided breast cancer patients. Material and Methods. Fifteen left-sided breast cancer patients who underwent radical mastectomy were enrolled. In TSP, the planning target volume (PTV) was divided into four regions (supra/infraclavicular, chest wall, external mammary region, and internal mammary region), and each individual PTV region was treated with respective fixed fields. Results. The VMAT plans showed superior to PTV dose conformity index (CI), homogeneity index (HI), protection of the ipsilateral lung, monitor units (MUs), and maximum dose (Dmax) to the contralateral breast compared with TSP and 9FIMRT plans. The TSP provided better protection for Dmean of the heart and left ventricle (p<0.05). A dose for left anterior descending artery from the three techniques had no significant difference. Compared with the 9FIMRT plans, the V5Gy (%) and V10Gy (%) for the ipsilateral lung were significantly reduced with TSP and VMAT (p<0.05). The V5Gy (%) and V10Gy (%) for the ipsilateral lung turned out to be similar between VMAT and TSP techniques. Conclusions. Our study indicates that VMAT should be a better choice of radiotherapy for left-sided breast cancer patients after radical mastectomy. If VMAT is unavailable, 9FIMRT can achieve better CI and HI values and be more MU-efficient compared with TSP; however, TSP can effectively reduce the low dose volume of the ipsilateral lungs and heart.


Sign in / Sign up

Export Citation Format

Share Document