scholarly journals Single port laparoscopic orchidopexy in children using surgical glove port and conventional rigid instruments

2015 ◽  
Vol 56 (11) ◽  
pp. 781 ◽  
Author(s):  
Ben Dhaou Mahdi ◽  
Chtourou Rahma ◽  
Jallouli Mohamed ◽  
Zitouni Hayet ◽  
Mhiri Riadh
2017 ◽  
Vol 80 (4) ◽  
pp. 327-332
Author(s):  
Mehmet Serif Arslan ◽  
Serkan Arslan ◽  
Hikmet Zeytun ◽  
Erol Basuguy ◽  
Bahattin Aydogdu ◽  
...  

2011 ◽  
Vol 15 (2) ◽  
pp. 165-171 ◽  
Author(s):  
R. Hompes ◽  
I. Lindsey ◽  
O. M. Jones ◽  
R. Guy ◽  
C. Cunningham ◽  
...  

2014 ◽  
Vol 86 (1) ◽  
pp. 35 ◽  
Author(s):  
Seung Eun Lee ◽  
Yoo Shin Choi ◽  
Beom Gyu Kim ◽  
Seong-Jae Cha ◽  
Joong-Min Park ◽  
...  

2010 ◽  
Vol 34 (10) ◽  
pp. 2487-2489 ◽  
Author(s):  
Michihiro Hayashi ◽  
Mitsuhiro Asakuma ◽  
Koji Komeda ◽  
Yoshiharu Miyamoto ◽  
Fumitoshi Hirokawa ◽  
...  

Animals ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 1242
Author(s):  
Georg Haider ◽  
Ursula Schulz ◽  
Nikola Katic ◽  
Christian Peham ◽  
Gilles Dupré

Single-port access systems (SPASs) are currently used in human and veterinary surgeries. However, they pose technical challenges, such as instrument crowding, intra- and extracorporeal instrument collision, and reduced maneuverability. Studies comparing the maneuverability of the scopes and instruments in different SPASs are lacking. This study aimed to compare the maneuverability of three different SPASs: the Covidien SILS-port, Storz Endocone, and glove port. A clear acrylic box with artificial skin placed at the bottom was used to mimic the abdominal wall and cavity. The three SPASs were placed from below, and a 10-mm endoscope and 5-mm instrument were introduced. A motion analysis system consisting of 18 cameras and motion analysis software were used to track the movement of the endoscope and instrument, to determine the volume of the cone-shaped, three-dimensional figures over which movement was possible, with higher values indicating greater maneuverability. The Mann–Whitney U test was used for the analysis. The maneuverability of the endoscope alone was significantly higher in the glove port system than in the other two SPASs. When inserting an additional instrument, the maneuverability significantly decreased in the SILS-port and Endocone, but not in the glove port. The highest maneuverability overall was found in the glove port.


2013 ◽  
Vol 23 (4) ◽  
pp. e160-e161 ◽  
Author(s):  
Erkinbek Orozakunov ◽  
Cihangir Akyol ◽  
Utku Tantoglu ◽  
Salim I. Basceken ◽  
Ilgaz S. Kayilioglu ◽  
...  

2010 ◽  
Vol 73 (2) ◽  
pp. 142-145 ◽  
Author(s):  
Elbert Khiangte ◽  
Iheule Newme ◽  
Partha Phukan ◽  
Santanu Medhi

2016 ◽  
Vol 223 (4) ◽  
pp. e35-e41
Author(s):  
Elio Jovine ◽  
Simone Nicosia ◽  
Michele Masetti ◽  
Raffaele Lombardi ◽  
Claudia Benini ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document