scholarly journals Maneuverability of the Scope and Instruments within Three Different Single-Incision Laparoscopic Ports: An Experimental Pilot Study

Animals ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 1242
Author(s):  
Georg Haider ◽  
Ursula Schulz ◽  
Nikola Katic ◽  
Christian Peham ◽  
Gilles Dupré

Single-port access systems (SPASs) are currently used in human and veterinary surgeries. However, they pose technical challenges, such as instrument crowding, intra- and extracorporeal instrument collision, and reduced maneuverability. Studies comparing the maneuverability of the scopes and instruments in different SPASs are lacking. This study aimed to compare the maneuverability of three different SPASs: the Covidien SILS-port, Storz Endocone, and glove port. A clear acrylic box with artificial skin placed at the bottom was used to mimic the abdominal wall and cavity. The three SPASs were placed from below, and a 10-mm endoscope and 5-mm instrument were introduced. A motion analysis system consisting of 18 cameras and motion analysis software were used to track the movement of the endoscope and instrument, to determine the volume of the cone-shaped, three-dimensional figures over which movement was possible, with higher values indicating greater maneuverability. The Mann–Whitney U test was used for the analysis. The maneuverability of the endoscope alone was significantly higher in the glove port system than in the other two SPASs. When inserting an additional instrument, the maneuverability significantly decreased in the SILS-port and Endocone, but not in the glove port. The highest maneuverability overall was found in the glove port.

2020 ◽  
Vol 33 (5) ◽  
pp. 761-767
Author(s):  
Yongwook Kim ◽  
Seungmook Kang

BACKGROUND: Few studies have explored the relationship between muscle strength, range of motion (ROM), and balance in the horizontal plane of the hip joint using three-dimensional (3D) motion analysis. OBJECTIVE: We investigate the relationships of hip internal rotation (IR) and external rotation (ER) ROM, measured using a 3D motion capture system, with hip internal and external rotator strength and single-leg standing balance. METHODS: The participants were 40 healthy adults. Kinematic data on hip ROM were collected using an eight-camera motion analysis system. Hip rotational strength measurements were obtained using hand-held isometric dynamometry. A Single-leg standing test and a pendular test were conducted to evaluate static and dynamic balance ability using BioRescue. RESULTS: Significant correlations were found between hip strength and each variable measured during hip ROM assessments (p< 0.05). Significant positive correlations were found between the hip IR/ER strength ratio and the IR/ER ROM ratio (r= 0.72, p< 0.01). The subgroup with a normal IR/ER ratio of hip rotator strength and ROM showed significantly better dynamic balance ability than the subgroup with a hip rotator muscle imbalance (p< 0.05). CONCLUSIONS: There is a significant relationship between hip IR/ER strength and IR/ER ROM with a normal hip IR/ER strength and ROM ratio positively affecting dynamic balance ability.


Author(s):  
S. F. Almashqbeh

The kinematic and kinetic differences between two styles of stair climbing, namely regular stair climbing (RSC) and lateral stair climbing (LSC), was studied. A four-step wooden stair instrumented with two force plates was used as the action platform. The kinematic and kinetic recordings were collected using a 6-camera, 2-force plate commercial three-dimensional motion analysis system. The LSC activity was subdivided into LSCL activity, where the right leg was the leading leg, and LSCT.


2012 ◽  
Vol 2012 ◽  
pp. 1-5 ◽  
Author(s):  
Young-Sam Choi ◽  
Kwang-Sik Shin ◽  
Jin Choi ◽  
Ji-No Park ◽  
Yun-Sang Oh ◽  
...  

Objectives.To present our initial experiences with laparoscopically assisted vaginal hysterectomy performed using homemade transumbilical single-port system.Materials and Methods.We reviewed the medical records of one hundred patients who underwent single-port access laparoscopically assisted vaginal hysterectomy (SPA-LAVH). SPA-LAVH was performed with homemade single port system and conventional rigid laparoscopic instruments.Results.All procedures were successfully completed through the single-port system and vagina without need for extraumbilical puncture or conversion to laparotomy. The median patient age was 48.2 ± 6.5 years. Thirty-three patients had history of past abdominopelvic surgery. The median total operative time, largest dimension of the uterus, and weight of the uterus were 73.1 ± 24.6 min, 10.5 ± 2.1 cm, and 300.8 ± 192.5 gram, respectively. The median decline in the hemoglobin from before surgery to postoperative day 1 was 1.8 ± 0.9 g/dL. Bladder injury in occurred one patient who was repaired through intraoperative laparoscopic suture. The postoperative course was uneventful in most patients except for three who had a transient paralytic ileus, five who had pelvic hematoma, but they were recovered following conservative managements. No port-related complications were noted, and the cosmetic results were excellent.Conclusions.SPA-LAVH is technically safe procedure, and the homemade single-port system offers reliable access for single-port surgery.


2015 ◽  
Vol 24 (12) ◽  
pp. 2807-2815 ◽  
Author(s):  
Haruhi Inokuchi ◽  
Michio Tojima ◽  
Hiroshi Mano ◽  
Yuki Ishikawa ◽  
Naoshi Ogata ◽  
...  

2007 ◽  
Vol 31 (2) ◽  
pp. 157-166 ◽  
Author(s):  
N. Ramstrand ◽  
K. -Å Nilsson

The ability to objectively measure an amputee's walking activity over prolonged periods can provide clinicians with a useful means of evaluating their patients' outcomes. The present study aimed to validate the temporospatial data output from a commercially available ambulatory activity monitor (PAM, Össur) fitted to trans-tibial and trans-femoral amputees, against data that was simultaneously captured from a three dimensional motion analysis system (Qualisys Medical AB, Gothenburg, Sweden). Results indicate that the PAM monitor provides accurate measures of temporospatial aspects of amputee gait for walking speeds above 0.75 m/s.


2018 ◽  
Vol 8 (6) ◽  
pp. 23-26
Author(s):  
Liem Ngo Thanh ◽  
Hung Nguyen Khoa ◽  
Tung Hoang Van

Objective: Outcome of 45 retroperitoneal single incision laparoscopic nephrectomy of benigns nonfunction kidneys at Hue Central Hospital. Patients and method: A prospective study was perform on 45 patients with benign nonfuncion kidney, treated by retroperitoneal single incision laparoscopic nephrectomy at Department of General Surgery - Hue Central Hospital from May 2015 to August 2018. Results: Success: 42/45 patients. Mean operating time 87.5mins (50 - 155 mins), postoperative hospital stay 5-7 days. SILS Port of Covidien was inserted by 2.5 cm skin transverse incision, standard straight laparoscopic instruments were used instead of roticular instruments. Conclusion: This is a mini-invasive technical, safety and cosmetic Keywords: retroperitoneal single incision laparoscopic nephrectomy, single port nephrectomy.


Author(s):  
Hwai-Ting Lin ◽  
Yu-Chuan Lin ◽  
You-Li Chou ◽  
Hung-Chien Wu ◽  
Rong-Tyai Wang ◽  
...  

Previous studies have reported that pitchers with glenohumeral internal rotation deficit (GIRD) may increase the risk of shoulder injury. However, limited information is available regarding the specific effects of GIRD in baseball pitching. The purpose of this study was to investigate whether baseball pitchers with GIRD change their pitching mechanism. Fifteen baseball pitchers with GIRD and 15 pitchers without GIRD were recruited from university or senior high-school teams. A three-dimensional motion analysis system (Eagle System, Motion Analysis Corporation, Santa Rosa, CA, USA) was used to capture the pitching motion while performing fastball pitches. The kinematics and kinetics of the throwing shoulder and trunk were analyzed based on motion captured data. The Mann–Whitney U test was used to test the differences of the analyzed parameters between two groups. At the instant of ball release, the GIRD group showed lower shoulder external rotation and trunk rotation, and larger shoulder horizontal adduction. In addition, the GIRD group exhibited a significantly larger shoulder inferior force in the cocking and acceleration phase, and a significantly larger internal rotation torque in the acceleration phase. The present results suggested that pitchers with GIRD need stretch training to enlarge joint range of motion, and to improve trunk strength and flexibility to alleviate potential problems associated with pitching in GIRD pitchers.