The Effects of Core Stability Exercise Using an Ultrasound Imaging System on Muscle Activation of Shoulder Region

Author(s):  
Jang Yeon Cho ◽  
Jae Hun Shim ◽  
Ho Young Choi ◽  
Ki Min Song ◽  
Seoug Il Moon ◽  
...  
Author(s):  
Seongwook Choi ◽  
Jin Young Kim ◽  
Hae Gyun Lim ◽  
Jin Woo Baik ◽  
Hyung Ham Kim ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2858
Author(s):  
Kelly Ka-Lee Lai ◽  
Timothy Tin-Yan Lee ◽  
Michael Ka-Shing Lee ◽  
Joseph Chi-Ho Hui ◽  
Yong-Ping Zheng

To diagnose scoliosis, the standing radiograph with Cobb’s method is the gold standard for clinical practice. Recently, three-dimensional (3D) ultrasound imaging, which is radiation-free and inexpensive, has been demonstrated to be reliable for the assessment of scoliosis and validated by several groups. A portable 3D ultrasound system for scoliosis assessment is very much demanded, as it can further extend its potential applications for scoliosis screening, diagnosis, monitoring, treatment outcome measurement, and progress prediction. The aim of this study was to investigate the reliability of a newly developed portable 3D ultrasound imaging system, Scolioscan Air, for scoliosis assessment using coronal images it generated. The system was comprised of a handheld probe and tablet PC linking with a USB cable, and the probe further included a palm-sized ultrasound module together with a low-profile optical spatial sensor. A plastic phantom with three different angle structures built-in was used to evaluate the accuracy of measurement by positioning in 10 different orientations. Then, 19 volunteers with scoliosis (13F and 6M; Age: 13.6 ± 3.2 years) with different severity of scoliosis were assessed. Each subject underwent scanning by a commercially available 3D ultrasound imaging system, Scolioscan, and the portable 3D ultrasound imaging system, with the same posture on the same date. The spinal process angles (SPA) were measured in the coronal images formed by both systems and compared with each other. The angle phantom measurement showed the measured angles well agreed with the designed values, 59.7 ± 2.9 vs. 60 degrees, 40.8 ± 1.9 vs. 40 degrees, and 20.9 ± 2.1 vs. 20 degrees. For the subject tests, results demonstrated that there was a very good agreement between the angles obtained by the two systems, with a strong correlation (R2 = 0.78) for the 29 curves measured. The absolute difference between the two data sets was 2.9 ± 1.8 degrees. In addition, there was a small mean difference of 1.2 degrees, and the differences were symmetrically distributed around the mean difference according to the Bland–Altman test. Scolioscan Air was sufficiently comparable to Scolioscan in scoliosis assessment, overcoming the space limitation of Scolioscan and thus providing wider applications. Further studies involving a larger number of subjects are worthwhile to demonstrate its potential clinical values for the management of scoliosis.


Micromachines ◽  
2020 ◽  
Vol 11 (9) ◽  
pp. 861
Author(s):  
Elizabeth E. Niedert ◽  
Chenghao Bi ◽  
Georges Adam ◽  
Elly Lambert ◽  
Luis Solorio ◽  
...  

A microrobot system comprising an untethered tumbling magnetic microrobot, a two-degree-of-freedom rotating permanent magnet, and an ultrasound imaging system has been developed for in vitro and in vivo biomedical applications. The microrobot tumbles end-over-end in a net forward motion due to applied magnetic torque from the rotating magnet. By turning the rotational axis of the magnet, two-dimensional directional control is possible and the microrobot was steered along various trajectories, including a circular path and P-shaped path. The microrobot is capable of moving over the unstructured terrain within a murine colon in in vitro, in situ, and in vivo conditions, as well as a porcine colon in ex vivo conditions. High-frequency ultrasound imaging allows for real-time determination of the microrobot’s position while it is optically occluded by animal tissue. When coated with a fluorescein payload, the microrobot was shown to release the majority of the payload over a 1-h time period in phosphate-buffered saline. Cytotoxicity tests demonstrated that the microrobot’s constituent materials, SU-8 and polydimethylsiloxane (PDMS), did not show a statistically significant difference in toxicity to murine fibroblasts from the negative control, even when the materials were doped with magnetic neodymium microparticles. The microrobot system’s capabilities make it promising for targeted drug delivery and other in vivo biomedical applications.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Paolo Formenti ◽  
Michele Umbrello ◽  
Martin Dres ◽  
Davide Chiumello

Abstract Although mechanical ventilation is a lifesaving treatment, abundant evidence indicates that its prolonged use (1 week or more) promotes respiratory muscle weakness due to both contractile dysfunction and atrophy. Along with the diaphragm, the intercostal muscles are one of the most important groups of respiratory muscles. In recent years, muscular ultrasound has become a useful bedside tool for the clinician to identify patients with respiratory muscle dysfunction related to critical illness and/or invasive mechanical ventilation. Images obtained over the course of illness can document changes in muscle dimension and can be used to estimate changes in function. Recent evidence suggests the clinical usefulness of ultrasound imaging in the assessment of intercostal muscle function. In this narrative review, we summarize the current literature on ultrasound imaging of the parasternal intercostal muscles as used to assess the extent of muscle activation and muscle weakness and its potential impact during discontinuation of mechanical ventilation. In addition, we proposed a practical flowchart based on recent evidence and experience of our group that can be applied during the weaning phase. This approach integrates multiple predictive parameters of weaning success with respiratory muscle ultrasound.


2014 ◽  
Vol 19 (07) ◽  
pp. 1 ◽  
Author(s):  
Umar S. Alqasemi ◽  
Hai Li ◽  
Guangqian Yuan ◽  
Patrick D. Kumavor ◽  
Saeid Zanganeh ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document