scholarly journals Effect of Right Supine Tracheal Extubation on Respiratory Complications and Airway Pressure in the Waking Period of General Anesthesia in Pediatric Stomatology

2021 ◽  
Vol 11 (12) ◽  
pp. 347-354
Author(s):  
Zhijun Xin ◽  
Ning Wang ◽  
Huaizhou Wang ◽  
Changhui Li ◽  
Tianfeng Wang<sup>#</sup>
2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Shunichi Murakami ◽  
Shunsuke Tsuruta ◽  
Kazuyoshi Ishida ◽  
Atsuo Yamashita ◽  
Mishiya Matsumoto

Abstract Background Excessive dynamic airway collapse (EDAC) is an uncommon cause of high airway pressure during mechanical ventilation. However, EDAC is not widely recognized by anesthesiologists, and therefore, it is often misdiagnosed as asthma. Case presentation A 70-year-old woman with a history of asthma received anesthesia with sevoflurane for a laparotomic cholecystectomy. Under general anesthesia, she developed wheezing, high inspiratory pressure, and a shark-fin waveform on capnography, which was interpreted as an asthma attack. However, treatment with a bronchodilator was ineffective. Bronchoscopy revealed the collapse of the trachea and main bronchi upon expiration. We reviewed the preoperative computed tomography scan and saw bulging of the posterior membrane into the airway lumen, leading to a diagnosis of EDAC. Conclusions Although both EDAC and bronchospasm present as similar symptoms, the treatments are different. Bronchoscopy proved useful for distinguishing between these two entities. Positive end-expiratory pressure should be applied and bronchodilators avoided in EDAC.


2020 ◽  
Vol 3 (2) ◽  
pp. 46-49
Author(s):  
Hunsehalli Revanasiddappa Narendra ◽  
Aparna Nerurkar ◽  
Shibu Sasidharan

ABSTRACT Background Laparoscopic surgery is performed under general anesthesia with mechanical ventilation, and a high-volume, low-pressure endotracheal tube (ETT) with a sealing cuff pressure about 20–30 cm of H2O is commonly used for a proper seal and avoidance of overinflation. Nitrous oxide (N2O) is an inhalational anesthetic that is used with oxygen in the ratio 50:50 for the maintenance of anesthesia if there is no facility of medical air. However, N2O increases the intracuff pressure of the tracheal tube due to diffusion of N2O in to cuff during general anesthesia. The present research was done to study the cuff pressure changes during laparoscopic surgeries with N2O anesthesia and to assess its variation during the various stages of surgery and also its correlation with position of the patient. Materials and methods A study was done in a tertiary-level hospital over a period of 1 year in 70 patients undergoing laparoscopic surgery. Endotracheal tube was inflated with incremental doses of 0.5 mL of air to a point where no leak on auscultation on the suprasternal area was noted. Cuff pressure measurement using cuff pressure monitor (Hand pressure gauge) was done at the time of first inflation of cuff up to 20–30 cm of H2O and airway pressure, along with total amount of air inflated was noted as “zero” reading. Thereafter, cuff pressure was measured at regular interval of 5 minutes. Cuff pressures and airway pressures were taken just prior to insufflation, 2 minutes after abdominal insufflation, thereafter every 15 minutes throughout surgery, and 2 minutes after desufflation and prior to extubation. Results Out of 70 patients, maximum patients were of the age-group of 20–50 years (78.5%). There was no statistically significant difference between the groups. Cuff pressure at the induction was kept in range of 20–30 cm of H2O. In this study, mean tracheal cuff pressure at baseline was 21.10 + 6.16 (p value of 0.207) and prior to insufflation was 21 + 7.13 (p value of 0.733). The cuff pressures at 2 minutes post insufflation (P2), P15, P30, P45, and P60 were 31.40 ± 12.54 cm of H2O, 25.79 ± 8.68 cm of H2O, 24.61 ± 7.37 cm of H2O, 23.83 ± 9.43 cm of H2O, and 24.63 ± 4.77 cm of H2O, respectively. p value was strongly significant showing a positive correlation between pneumo-peritoneum and cuff pressures. We could see the cuff pressure continuously increasing in successive readings. Post desufflation and prior to extubation, there was a fall in cuff pressure with mean cuff pressure being 17.24 + 5.32 cm of H2O and 15.27 + 4.00 cm of H2O, respectively, which also suggests that cuff pressures increased with pneumoperitoneum. Conclusion Use of N2O increases the cuff pressure (31.4 + 12.54 cm of H2O), especially immediately post-insufflation (35.54 + 12.06 cm of H2O), more so in head low position (36.28 + 12.13 cm of H2O). Mean airway pressure (Ppeak) also increased with pneumoperitoneum (22.60 + 4.38 cm of H2O). The regular monitoring of endotracheal tube cuff pressure should be a part of regular safe practice of anesthesia, and use of handy device like hand pressure gauge should be implemented in regular practice where N2O is used. How to cite this article Narendra HR, Nerurkar A, Sasidharan S. Observational Analysis of Changes in Endotracheal Tube Cuff Pressure During Laparoscopic Surgery. J Med Acad 2020;3(2):46–49.


2014 ◽  
Vol 24 (5) ◽  
pp. 578-585 ◽  
Author(s):  
Francesco Staffieri ◽  
Antonio Crovace ◽  
Valentina De Monte ◽  
Paola Centonze ◽  
Giulio Gigante ◽  
...  

2002 ◽  
Vol 95 (6) ◽  
pp. 1772-1776 ◽  
Author(s):  
Alexander Loeckinger ◽  
Axel Kleinsasser ◽  
Christian Keller ◽  
Andreas Schaefer ◽  
Christian Kolbitsch ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document