scholarly journals A Sensitive Reversed-Phase High-Performance Liquid Chromatography Method for the Quantitative Determination of Milk Xanthine Oxidase Activity

2013 ◽  
Vol 03 (01) ◽  
pp. 26-30 ◽  
Author(s):  
Zhongqin Li ◽  
Ruizhang Guan ◽  
Hongwei Liu
2014 ◽  
Vol 6 (16) ◽  
pp. 6560-6564 ◽  
Author(s):  
Wuxiang Zhang ◽  
Yicong Su ◽  
Jiangu Shi ◽  
Maosheng Zhang ◽  
Bide Wu ◽  
...  

In this paper, a high performance liquid chromatography technique is established for quantification of paraquat in blood.


2012 ◽  
Vol 10 (1) ◽  
pp. 216-223 ◽  
Author(s):  
Marcin Koba ◽  
Mariusz Belka ◽  
Tomasz Ciesielski ◽  
Tomasz Bączek

AbstractThe lipophilicity values of selected acridinone (imidazoacridinone and triazoloacridinone) derivatives were measured by gradient reversed-phase high-performance liquid chromatography (RP-HPLC) using a C18 stationary phase with a water/acetonitrile mixture as a mobile phase. The retention times obtained served as input data and appropriate log kw values (i.e., the retention factor log kw extrapolated to 0% organic modifier) as an alternative to log P were calculated using the DryLab program. The relationships between the lipophilicity (log kw) and the chemical structure of the studied compounds, as well as correlation between experimentally determined lipophilicities (log kw) and log P data calculated using some commonly available software, are discussed.


Author(s):  
Ramreddy Godela ◽  
Sherisha Bhavani

Objective: The most important objective of the present research work is to develop simple, specific, rapid, accurate, and sensitive reverse-phase high-performance liquid chromatography method and validated for the qualitative and quantitative determination of valsartan in its active pharmaceutical ingredient and tablet dosage form according to ICH guidelines.Proposed Method: An isocratic separation was done using Phenomenex C18 column possess 75×4.6 mm, 2.6 μ,100 A0 dimensions with mobile phase composition of water:acetonitrile (30:70% v/v) by maintaining 1 ml/minute flow rate and response detected at a wavelength of 247 nm.Results: The retention time of valsartan was found to be 2.71 minutes, limit of detection and limit of quantification were observed at 1.24 μg/ml and 3.6 μg/ml concentration, respectively, and a calibration curve was linear in the concentration range of 5-50 μg/ml with coefficient of correlation 0.99. The percentage recovery (accuracy) was in the range of 98.9-102%, and the % relative standard deviation was observed to be <2%.Conclusion: The proposed method was validated for accuracy, precision, sensitivity, linearity, and robustness and successfully employed for the quantitative determination of valsartan in tablet dosage form in quality control department of pharmaceutical industry.


Sign in / Sign up

Export Citation Format

Share Document