A Study of the Effect of Air-Mat Seat Pressure Level on Seating Comfort

2017 ◽  
Author(s):  
Se Jin Park ◽  
Murali Subramaniyam ◽  
Seunghee Hong ◽  
Damee Kim ◽  
Tae Hyun Kim ◽  
...  
2020 ◽  
Vol 63 (4) ◽  
pp. 931-947
Author(s):  
Teresa L. D. Hardy ◽  
Carol A. Boliek ◽  
Daniel Aalto ◽  
Justin Lewicke ◽  
Kristopher Wells ◽  
...  

Purpose The purpose of this study was twofold: (a) to identify a set of communication-based predictors (including both acoustic and gestural variables) of masculinity–femininity ratings and (b) to explore differences in ratings between audio and audiovisual presentation modes for transgender and cisgender communicators. Method The voices and gestures of a group of cisgender men and women ( n = 10 of each) and transgender women ( n = 20) communicators were recorded while they recounted the story of a cartoon using acoustic and motion capture recording systems. A total of 17 acoustic and gestural variables were measured from these recordings. A group of observers ( n = 20) rated each communicator's masculinity–femininity based on 30- to 45-s samples of the cartoon description presented in three modes: audio, visual, and audio visual. Visual and audiovisual stimuli contained point light displays standardized for size. Ratings were made using a direct magnitude estimation scale without modulus. Communication-based predictors of masculinity–femininity ratings were identified using multiple regression, and analysis of variance was used to determine the effect of presentation mode on perceptual ratings. Results Fundamental frequency, average vowel formant, and sound pressure level were identified as significant predictors of masculinity–femininity ratings for these communicators. Communicators were rated significantly more feminine in the audio than the audiovisual mode and unreliably in the visual-only mode. Conclusions Both study purposes were met. Results support continued emphasis on fundamental frequency and vocal tract resonance in voice and communication modification training with transgender individuals and provide evidence for the potential benefit of modifying sound pressure level, especially when a masculine presentation is desired.


1986 ◽  
Vol 29 (3) ◽  
pp. 420-424 ◽  
Author(s):  
Michael Dorman ◽  
Ingrid Cedar ◽  
Maureen Hannley ◽  
Marjorie Leek ◽  
Julie Mapes Lindholm

Computer synthesized vowels of 50- and 300-ms duration were presented to normal-hearing listeners at a moderate and high sound pressure level (SPL). Presentation at the high SPL resulted in poor recognition accuracy for vowels of a duration (50 ms) shorter than the latency of the acoustic stapedial reflex. Presentation level had no effect on recognition accuracy for vowels of sufficient duration (300 ms) to elicit the reflex. The poor recognition accuracy for the brief, high intensity vowels was significantly improved when the reflex was preactivated. These results demonstrate the importance of the acoustic reflex in extending the dynamic range of the auditory system for speech recognition.


Author(s):  
Bi Asngali

 Penelitian ini bertujuan untuk menyelidiki pengaruh pressure level terhadap kekuatan geser sambungan single lap joint (SLJ) antara Al 2024 dan CFRP dengan adesif epoksi/serbuk Al. Variasi pressure level yang digunakan adalah 0,6; 0,7; 0,8; 0,9 dan 1 MPa. Pembuatan dan pengujian spesimen uji geser mengacu pada ASTM D 1002. Hasil penelitian menunjukkan bahwa pressure level dapat meningkatkan kekuatan geser sambungan. Pada variabel pressure level terbaiknya yaitu 0,9 MPa menghasilkan kekuatan geser tertinggi (8,59 MPa). Pada kondisi tersebut, penampang patahan menunjukkan jenis kegagalan kombinasi antara kegagalan cohesive, light fiber tear dan fiber-tear.Kata kunci— pressure level; epoksi/serbuk-Al; kekuatan geser; single lap joint .


2010 ◽  
Vol 130 (12) ◽  
pp. 2118-2123
Author(s):  
Akihiro Imai ◽  
Naoki Tokitsu ◽  
Koji Oguri
Keyword(s):  

Author(s):  
Aliza Sultana ◽  
Ashok Kumar Paul ◽  
Meher Un Nessa

This study was conducted in the Khulna metropolitan city to determine the status of noise pollution at major traffic intersections and assess the possible effect of noise on regular noise afflicted people. For this research, five busiest roadways and traffic intersections; two mixed zone and three commercial zones were selected purposively and 'ST-8850 Sound Level Meter' was used to record the noise pressure level. Average noise pressure level and some noise parameters (Leq, L10, L50, L90, and Lnp) were measured at different shifts in each location both on working days and holidays. The result evidently specified that noise level in all major traffic circles of Khulna metropolitan city was much higher than the recommended threshold of acceptable noise level set by the Department of Environment (DOE) of Bangladesh. It was observed that the mixed area (Sonadanga, Gollamari) tends to have a higher average noise level than those of the commercial area (Shibbari, Notunrasta, Dakbangla). The noise pollution level (Lnp) in mixed areas varied from 92.77 dB (A) to 104.74 dB(A) on working days and 86.9 dB(A) to 105.5 dB(A) on holidays. On working days, the highest Leq was observed 92.65 ± 4.15 dB(A) in Sonadanga (mixed area), whereas the lowest was 85.13 ± 2.83 dB(A) in Dakbangla (commercial area). However, on holidays the highest level of Leq was found 90.41 ± 2.25 dB(A) in Sonadanga, while the lowest levels were 80.43 ± 3.20 dB(A) in Dakbangla. One-way ANOVA with LSD post-hoc test results illustrated that on working days there was a significant difference between the noise pollution levels (NPL) in different shifts of day time (F = 8.412, p < .05). The respondents of the study area addressed that they were the most affected by annoyance (70%), headache (62%), and hearing loss (46%) due to regular exposure to the traffic noise. Therefore, it is recommended to enhance awareness regarding the cause and effect of noise pollution among the noise producers and oppressed people. Subsequently, administrative measures have to take to attenuate noise pollution and indemnify the quality health of the citizens.


2020 ◽  
Vol 68 (2) ◽  
pp. 137-145
Author(s):  
Yang Zhouo ◽  
Ming Gao ◽  
Suoying He ◽  
Yuetao Shi ◽  
Fengzhong Sun

Based on the basic theory of water droplets impact noise, the generation mechanism and calculation model of the water-splashing noise for natural draft wet cooling towers were established in this study, and then by means of the custom software, the water-splashing noise was studied under different water droplet diameters and water-spraying densities as well as partition water distribution patterns conditions. Comparedwith the water-splashing noise of the field test, the average difference of the theoretical and the measured value is 0.82 dB, which validates the accuracy of the established theoretical model. The results based on theoretical model showed that, when the water droplet diameters are smaller in cooling tower, the attenuation of total sound pressure level of the water-splashing noise is greater. From 0 m to 8 m away from the cooling tower, the sound pressure level of the watersplashing noise of 3 mm and 6 mm water droplets decreases by 8.20 dB and 4.36 dB, respectively. Additionally, when the water-spraying density becomes twice of the designed value, the sound pressure level of water-splashing noise all increases by 3.01 dB for the cooling towers of 300 MW, 600 MW and 1000 MW units. Finally, under the partition water distribution patterns, the change of the sound pressure level is small. For the R s/2 and Rs/3 partition radius (Rs is the radius of water-spraying area), when the water-spraying density ratio between the outer and inner zone increases from 1 to 3, the sound pressure level of water-splashing noise increases by 0.7 dB and 0.3 dB, respectively.


Sign in / Sign up

Export Citation Format

Share Document