scholarly journals The Correlation Between Protein Level in 24 Hour Urine Sample and Spot Urine Protein/Creatinine Ratio in the Elderly

2021 ◽  
Vol 0 (0) ◽  
pp. 0-0
Author(s):  
Özlem Karaarslan Cengiz ◽  
Volkan Atmış
Author(s):  
Ruma Sarkar ◽  
Shilpi Rawat ◽  
Neela Rai Sharma ◽  
Harish Chandra Tiwari

Background: Preeclampsia is defined as systolic blood pressure level of 140 mmHg or higher or a diastolic blood pressure level of 90 mmHg or higher that occurs after 20 weeks of gestation with proteinuria. Objective of this study was to study the role of spot urine protein: creatinine ratio as an alternative to 24 hours proteinuria for the diagnosis of pre-eclampsiaMethods: This is a prospective observational study conducted in the department of obstetrics and gynaecology, BRD Medical College Gorakhpur, since October 2016 to September 2017 included 120 pregnant women with hypertension of gestational age more than 20 weeks. Ramdom urine sample of all the patient was taken before 12 noon after first voiding. For 24 hours urine sample patient was asked to collect all her urine she voids during 24 hours. The creatinine was estimated by the alkaline picrate method (Jaffe's Reaction) modified by the Bonsnes and Taussky, 1945. Creatinine in a protein free solution reacts with the alkaline picrate and produces red colour complex which is measured colorimeterically. Urinary protein was estimated in all the subjects by the Turbidimetric method. Urinary protein was precipitated by 3% sulphosalicylic acid and turbidity so produced was measured colorimetrically.Results: Protein: creatinine ratio in a random urine sample is better than random urine protein detection by dipstick method in cases of emergency when there is no time for detection of 24 hours urine protein.Conclusions: If cut-off level for urine protein: creatinine ratio in random urine sample is taken as 0.25 or more then sensitivity and specificity become same as 24 hours urine protein.                                 


2021 ◽  
Author(s):  
Michael Abel Alao ◽  
Asinobi OA ◽  
Ibrahim OR ◽  
Lagunju IA

Abstract Background Although, the use of manual dipstick urinalysis for proteinuria has been a common practice, the Kidney Disease Improving Global Outcomes (KDIGO) guideline on screening for chronic renal disease least advocate it use. Besides, several studies have assessed the performance of dipstick urinary in screening for proteinuria to be inaccurate, unreliable with a poor predictive values. The goal of this study was to determine and compare the presence of significant proteinuria (SP) in high-risk African children using the spot urine protein creatinine ratio (UPr/UCr) as a primary screening tool besides dipstick proteinuria screening. Methods This cross-sectional study involved 1,316 apparently healthy children recruited through a multi-stage sampling technique in Ogbomoso land, Nigeria. We performed a dipstick urinalysis on early-morning urine samples. Urinary protein content was determined using a turbidimetric method and Jaffe’s reaction to measure the urinary creatinine concentration. Statistical analysis was performed using the IBM Statistical Package for Social Sciences (SPSS)TM, Version 23.0 for Windows. Results The prevalence of SP using spot UPr/UCr (≥ 0.2) and dipstick proteinuria screening (≥1+) were 18% and 0.8%, respectively (p<0.001). Of the 224 subjects determined to have SP using UPr/UCr, the females (140; 20.1%) had a higher proportion compared to males (84; 15.4% -p=0.032). Nephrotic range proteinuria was detected in nine out of 10 subjects (90%) using UPr/UCr but in only three out of ten (30%) using the urinary dipstick method. The biserial correlation coefficient (r= 0.092; p=0.001) and inter-rater-agreement (Cohen’s Kappa = 0.01) were poor, and the McNemar’s test result was (p<0.001). Conclusion The UPr/UCr ratio technique appeared to perform better than dipstick urinalysis as a primary screening tool for renal disease. Hence, it may be adopted for early detection of SP as a kidney disease marker especially among the high risk population.


2014 ◽  
Vol 9 (2) ◽  
pp. 45-53
Author(s):  
S Hossain ◽  
A Ghosh ◽  
A Chatterjee ◽  
G Sarkar ◽  
SS Mondal

Objective: This study was done to evaluate the diagnostic value of protein: creatinine ratio in a single voided urine sample for quantitation of proteinuria compared to those of a 24 hour urine sample in patients with preeclampsia. Methods: A prospective simple random sample study was done on the hypertensive pregnant women attending the antenatal clinic or admitted in Department of Obstetrics and Gynaecology. It included all women being evaluated for preeclampsia, regardless of the alerting sign or symptom, suspected severity or co-morbid conditions. The main measures were the urinary protein to urinary creatinine ratio by random (spot) direct measurement and the 24-h urinary protein excretion by a 24-h urine collection. The data obtained was statistically analyzed. Results: Out of the 78 patients with gestational hypertension included in our study 48 patients had significant proteinuria (e”300mg/day). Only 2 patients had proteinuria of the range of greater than 3500mg. Among the patients, 50 had a positive protein: creatinine ratio (e”0.3) while 28 patients had a negative protein: creatinine ratio (<0.3). The P: C ratio was able to correctly identify 44 out of 48 patients with significant proteinuria (when the comparison is made with the gold-standard test; i.e., 24-hour urine protein). It could also identify 24 out of 30 patients without significant proteinuria as compared to the gold-standard test. In this study, the Protein: Creatinine ratio with a sensitivity of 91.67%, a specificity of 80%, positive predictive values 88% and the negative predictive values 85.71%. Conclusions: Our data suggests that the protein: creatinine ratio in single voided urine is a highly accurate test (p value < 0.0000001) for discriminating between insignificant and significant proteinuria. Based on the above findings we conclude that a random urine protein excretion predicts the amount of 24- hour urine protein excretion with high accuracy. This could be a reasonable alternative to the 24-hour urine collection for detection of significant proteinuria in hospitalised pregnant women with suspected preeclampsia. Journal of College of Medical Sciences-Nepal, 2013, Vol-9, No-2, 45-53 DOI: http://dx.doi.org/10.3126/jcmsn.v9i2.9687


Author(s):  
Indu Kaul ◽  
Bawa Ram Bhagat ◽  
Deepika Sharma ◽  
Gagan Singh

Background: The measurement of albumin: creatinine ratio (ACR) in a spot urine sample avoids the influence of variation in urinary solute concentration and provides a more convenient and rapid method to assess protein excretion. The aim of this study was to evaluate urinary spot ACR as a new marker for proteinuria and to study its correlation and accuracy in comparison with 24-hour urinary protein.Methods: The prospective one-year study was conducted on 100 pregnant women, 18-40 years, >20 weeks gestation with a diagnosis of preeclampsia. A spot midstream urine sample was taken for detection of albuminuria by dipstick method. Another spot sample was taken for detection and calculation of spot ACR. The 24-hour urine collection was taken immediately afterward to evaluate 24-hour urinary protein excretion.Results: A positive linear relation exists between ACR and 24-hour urinary protein excretion The ROC revealed cut-off of 20.4 with 88.5% sensitivity, 75% specificity, 98.8% positive predictive value and 21.4% negative predictive value. Spot urinary ACR >20.4 correctly identified women having 24-hour urinary protein excretion in excess of 0.3 gm/DL.Conclusions: A strong correlation exists between single spot urinary ACR with 24-hour urinary protein excretion in women with preeclampsia.


2020 ◽  
Vol 149 (1) ◽  
pp. 76-81
Author(s):  
Angélique Berthet ◽  
Stéphanie Bartolo ◽  
Damien Subtil ◽  
Elodie Clouqueur ◽  
Charles Garabedian ◽  
...  

2017 ◽  
Vol 32 (6) ◽  
pp. 917-919
Author(s):  
Guido Filler ◽  
Shih-Han Susan Huang

2018 ◽  
Vol 36 (15_suppl) ◽  
pp. e20042-e20042
Author(s):  
Saad Jamshed ◽  
Jonathan Bress ◽  
Qiu Tong ◽  
Roberto Vargas

2017 ◽  
Vol 51 (4) ◽  
pp. 283-289 ◽  
Author(s):  
F. Vida Zohoori ◽  
A. Maguire

The urinary fluoride/creatinine ratio (UF/Cr) in a spot urine sample could be a useful systemic F exposure monitoring tool. No reference value for UF/Cr currently exists, therefore this study aimed to establish an upper reference value for a UF/Cr, corresponding to excessive systemic F exposure, i.e., >0.07 mg F/kg body weight (b.w.)/day, in children. Subsidiary aims were to examine the relationship between (i) total daily F intake (TDFI) and 24-h urinary F excretion (DUFE); (ii) DUFE and UF/Cr, and (iii) TDFI and UF/Cr. Simultaneously collected TDFI, DUFE, and urinary creatinine (UCr) data in children <7 years were taken from UK studies conducted from 2002 to 2014 in order to calculate UF/Cr (mg/g) for each child. For the 158 children (mean age 5.8 years) included in the data analysis, mean TDFI and DUFE were 0.049 (SD 0.033) and 0.016 (SD 0.008) mg/kg b.w./day, respectively, and the mean UF/Cr was 1.21 (SD 0.61) mg/g. Significant (p < 0.001) positive linear correlations were found between TDFI and DUFE, DUFE and UF/Cr, and TDFI and UF/Cr. The estimated upper reference value for UF/Cr was 1.69 mg/g; this was significantly (p = 0.019) higher than the UF/Cr (1.29) associated with optimal F exposure (0.05-0.07 mg/kg b.w./day). In conclusion, the strong positive correlation between TDFI and UF/Cr confirms the strong association of these 2 F exposure variables and the value of a spot urine sample for prediction of TDFI (i.e., the most important risk factor in determining fluorosis occurrence and severity) in young children. Establishing an estimation of an upper reference value of 1.69 mg/g for UF/Cr in spot urine samples could simplify and facilitate their use as a valuable tool in large epidemiological studies.


Sign in / Sign up

Export Citation Format

Share Document