scholarly journals On a Water Level Meter Using a Pressure Transducer of Semiconductor Strain Gauges for a Small Calibre Well

1976 ◽  
Vol 29 (3) ◽  
pp. 316-318
Author(s):  
Toshihiko YAMADA ◽  
Toshi ASADA
2015 ◽  
Vol 4 (1) ◽  
pp. 65-73 ◽  
Author(s):  
Z. Liu ◽  
C. W. Higgins

Abstract. Submersible pressure transducers have been utilized for collecting water level data since the early 1960s. Together with a digital data logger, it is a convenient way to record water level fluctuations for long-term monitoring. Despite the wide use of pressure transducers for water level monitoring, little has been reported regarding their accuracy and performance under field conditions. The effects of temperature fluctuations on the output of vented pressure transducers were considered in this study. The pressure transducers were tested under both laboratory and field conditions. The results of this study indicate that temperature fluctuation has a strong effect on the transducer output. Rapid changes in temperature introduce noise and fluctuations in the water level readings under a constant hydraulic head while the absolute temperature is also related to sensor errors. The former is attributed to venting and the latter is attributed to temperature compensation effects in the strain gauges. Individual pressure transducers responded differently to the thermal fluctuations in the same testing environment. In the field of surface hydrology, especially when monitoring fine-scale water level fluctuations, ignoring or failing to compensate for the temperature effect can introduce considerable error into pressure transducer readings. It is recommended that a performance test for the pressure transducer is conducted before field deployment.


Materials ◽  
2019 ◽  
Vol 12 (13) ◽  
pp. 2110 ◽  
Author(s):  
Michał Nowicki ◽  
Piotr Gazda ◽  
Roman Szewczyk ◽  
Andriy Marusenkov ◽  
Anton Nosenko ◽  
...  

The significant strain dependence of the hysteretic Giant Magnetoimpedance (GMI) effect in a Co67Fe3Cr3B12Si15 amorphous alloy in a low magnetizing field is presented. A simplistic test stand capable of continuous measurements of GMI characteristics under the influence of strain is detailed. Based on the results, a stress-impedance (SI) sensor is proposed, with a gauge factor similar to semiconductor strain gauges but more robust. An effective method of minimizing external magnetic field influence on the SI effect is given.


2016 ◽  
Author(s):  
Daniel Paczesny ◽  
Michał Marzęcki ◽  
Michał Woyke ◽  
Grzegorz Tarapata

Author(s):  
J.A. Hernandez-Nolasco ◽  
Miguel A. Wister Ovando ◽  
Francisco D. Acosta ◽  
Pablo Pancardo
Keyword(s):  

ELECTRICES ◽  
2021 ◽  
Vol 2 (2) ◽  
pp. 37-42
Author(s):  
Tiven Sandro ◽  
Hairatunnisa Hairatunnisa ◽  
Maulana Putra

Pengukuran tinggi muka air laut (water level) merupakan salah satu pengukuran parameter cuaca yang sangat penting di Indonesia mengingat wilayah Indonesia didominasi wilayah perairan. Pengukuran water level dimaksudkan sebagai data peringatan dini untuk mencegah kerugian yang ditimbulkan dari bencana seperti tsunami ataupun pasang gelombang yang tinggi. Dalam melakukan pengukuran water level terdapat beberapa jenis sensor yang digunakan, salah satunya adalah sensor dengan tipe pressure atau tekanan. Pada penelitian ini digunakan sensor water level pressure transducer tipe CS451 yang prinsip kerjanya adalah dengan membandingkan tekanan yang ada di dalam air dengan tekanan udara sebagai referensi dan menghitung selisih antara kedua tekanan tersebut. Selisih yang didapatkan kemudian di konversikan menjadi jarak. Metode yang digunakan dalam penelitian ini terdiri dari dua tahapan yaitu perancangan sistem alat dan evaluasi kinerja alat. Pengukuran yang dilakukan pada tanggal 16 Desember 2019 – 31 Januari 2020 menunjukan data yang baik dimana data tersebut membentuk grafik sinusiodal dengan data rata-rata 1.466 m, nilai data maksimum 2.066 m  dan nilai data minimum 0.821 m. Namun sensor water level mengalami permasalahan yang menyebabkan pengukuran yang dihasilkan menjadi tidak baik. Hal ini disebabkan salah satunya biota laut yaitu teritip yang menutupi sensor water level dan laju korosi pada sensor yang menyebabkan kerusakan pada sensor. Solusi yang harus dilakukan adalah dengan melakukan instalasi dan pemeliharaan dengan lebih baik, selain itu menggunakan cat anti-fouling agar kedepannya permasalahan yang sama tidak terulang kembali.


Sign in / Sign up

Export Citation Format

Share Document