scholarly journals Three-Dimensional Evaluation of Anterior Acetabular Coverage of the Femoral Head.

1993 ◽  
Vol 42 (1) ◽  
pp. 328-331 ◽  
Author(s):  
Etsuo Chosa ◽  
Naoya Tajima ◽  
Yoshitaka Nagatsuru
Author(s):  
Vidyadhar V. Upasani ◽  
Megan E. Jeffords ◽  
Christine L. Farnsworth ◽  
David Padilla ◽  
Nick Lopreiato ◽  
...  

2020 ◽  
Vol 8 (4_suppl3) ◽  
pp. 2325967120S0020
Author(s):  
Elizabeth Graesser ◽  
Maria Schwabe ◽  
Sean Akers ◽  
Cecilia Pascual-Garrido ◽  
John C Clohisy ◽  
...  

Introduction: Assessment of anterior acetabular coverage is commonly done with measurement of the anterior center edge angle (ACEA) or anterior wall index (AWI). This is particularly important in cases of borderline acetabular dysplasia where it may influence treatment decisions. However, the ACEA and AWI has been poorly validated. Purpose: The purpose of the current study was to investigate the correlation between plain radiographic measurements and three-dimensional femoral head coverage on low-dose CT in borderline acetabular dysplasia. Methods: Seventy consecutive hips with borderline acetabular dysplasia (LCEA 20-25°) were included in the current study. Radiographic evaluation was performed prospectively including LCEA, acetabular inclination, and AWI on AP pelvis radiographs, and ACEA on false profile radiographs. The mean LCEA was 22.1±1.4°, while the mean acetabular inclination was 10.3±3.3. All patients underwent low-dose pelvic CT assessment for preoperative planning. The radial acetabular coverage was calculated according to the standardized clock-face position [measured at 12:00 (lateral), 1:00, 2:00, 3:00 (anterior), and 4:00] as described by Larson et al. Statistical analysis determined the correlation between ACEA and radial coverage. Results: The mean ACEA in the group was 25.3±5.8° (range 10.1-43.9), with 16% having ACEA≤20° and 50% having ACEA≤25°. The mean radial coverages were 63.5%±1.7 (12:00), 60.7%±2.2 (1:00), 50.8%±3.2 (2:00), 37.0%±3.3 (3:00), and 27.9%±3.1 (4:00). The ACEA had poor correlation with radial coverage at all positions from 12:00 to 4:00 (range –0.068-0.173). The AWI had moderate correlation with radial coverage at 3:00 (PCC 0.499) and 4:00 (PCC 0.573). Comparing hips with an ACEA <20° versus >20°, there was no difference between the mean radial acetabular coverage at any position 12:00-4:00 (p=0.18-0.95). Comparing hips with an ACEA <25° versus >25°, there was no difference between the mean radial acetabular coverage at any position 12:00-4:00 (p=0.12-0.71). No significant difference in AWI was present between subgroups with normal and deficient radial coverage from 12:00 to 4:00 (p=0.09-0.72). Discussion: The current study demonstrates poor correlation of the ACEA measurement with true anterior femoral head coverage as evaluated at clock-face positions from 12:00 to 4:00. The AWI demonstrated moderate correlation for 3:00-4:00 coverage but fails to differentiate hips with normal and deficient coverage. In the setting of borderline acetabular dysplasia, anterior and anterolateral femoral coverage should be assessed via low-dose CT rather than ACEA or AWI.


2021 ◽  
Vol 9 (7_suppl3) ◽  
pp. 2325967121S0016
Author(s):  
Elizabeth Graesser ◽  
Maria Schwabe ◽  
Cecilia Pascual Garrido ◽  
John C. Clohisy ◽  
Jeffrey J. Nepple

Introduction: Borderline acetabular dysplasia is classically defined as a lateral center edge angle (LCEA) of 20-25 degrees. The optimal treatment strategy in this patient group remains controversial, with some patients having primarily hip instability-based symptoms, while others have primarily impingement-based symptoms (non-instability). The purpose of the current study was to define the 3D characteristics on low-dose CT that differentiate patients with instability symptoms from those without instability in the setting of borderline acetabular dysplasia. Methods: Seventy consecutive hips with borderline acetabular dysplasia undergoing surgical treatment were included in the current study. All patients underwent low-dose pelvic CT with femoral version assessment for preoperative planning. CT measurements included alpha angle and radial acetabular coverage (RAC) at standardized clockface positions (9:00-posterior to 3:00-anterior), central and cranial acetabular version. RAC was assessed in three sectors (anterior, superior, and posterior) and defined (relative to published normative data) as normal (-1 SD, +1 SD), undercoverage (<-1 SD), or overcoverage (>+1 SD). Statistical analysis was performed to compare the CT characteristics of the symptomatic instability and non-instability groups. Results: Of the 70 hips, 62.9% had the diagnosis of symptomatic instability, while 37.1% had no instability symptoms. Hips with instability (compared to non-instability) had significantly lower alpha angle (maximal difference at 1:00 - 47.0° vs. 59.4°), increased femoral version (22.3° vs. 15.3°), and decreased radial acetabular coverage (maximal difference at 1:00 – 59.9% vs. 62.2%) (all p<0.001). Multivariate analysis identified femoral version (OR 1.1, p=0.02), alpha angle at 1:00 (OR 0.91, p=0.02), and RAC at 1:00 (OR 0.46, p=0.003) as independent predictors of the presence of instability. The model combining these three factors had excellent predictive probability with a c-statistic 0.92. Conclusion: We found significant differences in the 3D hip morphology of the symptomatic instability and non-instability subgroups within the borderline dysplasia cohort. In the setting of borderline dysplasia, three-dimensional deformity characterization with low-dose CT allowed for differentiation of patients diagnosed with underlying instability vs. non-instability. Femoral version, alpha angle at 1:00, and radial acetabular coverage at 1:00 were identified as independent predictors of diagnosis in borderline acetabular dysplasia. Summary: This study attempts to define 3D CT characteristics to help distinguish between patients with impingement-based vs instability-based symptoms of borderline acetabular dysplasia.


2013 ◽  
Vol 2013 ◽  
pp. 1-4 ◽  
Author(s):  
Tomohiro Mimura ◽  
Taku Kawasaki ◽  
Keitaro Yagi ◽  
Kanji Mori ◽  
Shinji Imai ◽  
...  

We report a case of a 27-year-old man with pigmented villonodular synovitis of the hip joint with coincident osteonecrosis of the femoral head. According to our review of the English-language literature, no detailed report of osteonecrosis of the femoral head complicated with pigmented villonodular synovitis has been published. Preoperative X-ray images showed joint narrowing and severe multiple bone erosions at the acetabulum and femoral neck. Magnetic resonance imaging revealed a low-intensity band attributable to osteonecrosis of the femoral head and massive diffuse pigmented villonodular synovitis lesions. Comparison of a three-dimensional computed tomographic image of this patient with an angiographic image of a normal individual demonstrated proximity of the pigmented villonodular synovitis-induced bone erosions to the medial and lateral femoral circumflex arteries and retinacular arteries, suggesting likely the compromise of the latter by the former. We propose that the massive pigmented villonodular synovitis may have contributed to the pathogenesis of osteonecrosis of the femoral head in this patient. We performed open synovectomy and total hip arthroplasty. No operative complications occurred, and no recurrence of the pigmented villonodular synovitis was detected for 3 years after the operation.


2020 ◽  
Vol 8 (7_suppl6) ◽  
pp. 2325967120S0039
Author(s):  
Layla Haidar ◽  
Ryan Warth ◽  
Erinn Pemberton Annie Waite ◽  
Alfred Mansour

Objectives: Cam-type femoroacetabular impingement (FAI) is a three-dimensional (3D) deformity that is still difficult to assess using traditional two-dimensional (2D) radiographic views. While measurements of alpha angle and head-neck offset are used to estimate the likelihood of actual impingement, these 2D measurements do not account for z-axis variations in femoral version (FV) and neck-shaft angle (NSA). The purpose of this qualitative proof-of-concept study was to evaluate the potential variation in alpha angle and neck-shaft offset measurements with incremental changes in NSA and FV by simulating traditional radiographic views with software-generated Digitally-Reconstructed Radiographs (DRRs). We hypothesize that incremental changes in hip morphology will produce qualitative changes in alpha angle and neck-shaft offset. Methods: 3D-CT reconstruction images were obtained from one subject with symptomatic cam-type FAI. The 3D reconstruction was cleaned to include only the femoral head, neck and subtrochanteric region along with the ipsilateral hemipelvis. Using 3D medical image processing software (Mimics; Materialise, Inc.; Belgium), the pre-processed 3D model was manipulated in a standardized manner to simulate 5-degree incremental variations in FV and NSA (-15 degrees to +15 degrees for FV; -15 degrees to +10 degrees for NSA). Negative FV reflected external rotation of the femoral head-neck unit, whereas negative NSA reflected abduction of the femoral head-neck unit. Each modified 3D model was then used to generate DRRs corresponding to traditional 2D radiographic views used for assessment of cam-FAI (Anteroposterior [AP], False Profile [FP]), Cross Table Lateral [CTL], Frog Leg Lateral [FLL], 45- and 90-degree Dunn [45D and 90D, respectively]. Alpha angle and head-neck offset were measured on each radiographic view corresponding to each incremental change in FV and NSA. All measurements utilized the perfect circle technique and were made by two independent observers for assessment of inter-observer reliability. Two-way random effects ANOVA was used for statistical assessment of inter-observer reliability and reported as intra-class correlation coefficients (κ). Comparisons between groups were performed using two-tailed paired t-tests assuming unequal variance. P-values less than 0.05 were considered statistically significant. Results: Inter-observer reliability (κ) for head-neck offset and alpha angles were 0.46 (fair) and 0.88 (excellent), respectively. Variations in head-neck offset and alpha angle with incremental variations in FV and NSA are summarized in Figure 1. There were statistically significant changes in mean alpha angles when the NSA was adjusted from Neutral to -5 degrees (p=0.01) and from -5 degrees to -10 degrees (p<0.001). There were no statistically significant differences in alpha angles or head-neck offsets between each incremental change in FV (p<0.05). Alpha angle measurements were significantly more variable than head-neck offset measurements for all variations in FV (p<0.001) and NSA (p=0.02) (Figure 2). Conclusion: Two-dimensional evaluation of three-dimensional Cam morphology (alpha angle and head-neck offset) was found to be significantly affected by alterations in femoral version and head-neck offset. Head-neck offset measurements were significantly less variable than alpha angle measurements across all FVs and NSAs within each radiographic view. Future work should be done to develop standardized procedures for routine 3D radiographic assessment of cam-type FAI. [Figure: see text][Figure: see text]


2020 ◽  
Vol 2020 ◽  
pp. 1-5
Author(s):  
Liangliang Cheng ◽  
Xing Qiu ◽  
Lei Yang ◽  
Chi Xiao ◽  
Baoyi Liu ◽  
...  

Objective. To investigate the feasibility of using 3D printed personalized guide plates in core decompression procedures for the treatment of osteonecrosis of the femoral head (ONFH). Methods. The clinical data of 8 patients undergoing femoral head core decompression from January to December 2019 were analyzed retrospectively. Three-dimensional (3D) images of the patients were reconstructed from the CT scan data taken preoperatively. From the data obtained, puncture position, drill hole, and depth were evaluated, and individualized 3D puncture guide plates were designed using Mimics 21.0 software. During the operation, the needle went through the hole of the guide plate, the depth of the drill was controlled, and the obtained bone tissues were sent for pathological evaluation. Intraoperative X-ray and postoperative pathological results were used to evaluate the success of the puncture. Results. The individualized guide plates used for core compression on the 8 patients were well fitted with the anatomic structure of the puncture site, and the direction and depth of the needle insertion were consistent with the preoperative design. The operation time was about 15-22 mins. The position of the decompression tunnel was the same as the designed plate. The postoperative pathology showed necrotic bone tissue. There were no postoperative complications such as infection, bleeding, and fracture. Conclusion. The 3D printed individualized guide plate can simplify core decompression and would make this procedure more accurate, safe, and quick, in addition to obtaining necrotic tissues for pathological examination.


Sign in / Sign up

Export Citation Format

Share Document