scholarly journals The heat leakage measurement of dewars for infrared detector arrays

2021 ◽  
pp. 58-67
Author(s):  
Dmitrii Maslov ◽  
Vladimir Kulikov ◽  
Anton Barabanov

Consideration is given to the analysis of a number of implementation of calorimetry method of infrared detector array dewar’s heat leakage measurements. The heat leakage measurements were made both with and without nitrogen vapor heat capacity consideration. The heat exchange process between nitrogen vapor and Dewar’s well walls was analyzed. The most reliable results were achieved by means of approach with calibration.

Author(s):  
Л. А. Кущев ◽  
В. Н. Мелькумов ◽  
Н. Ю. Саввин

Постановка задачи. Рассматривается теплообменный процесс, протекающий в модифицированном гофрированном межпластинном канале интенсифицированного пластинчатого теплообменного аппарата с повышенной турбулизацией теплоносителя. Необходимо разработать компьютерную модель движения теплоносителя в диапазоне скоростей 0,1-1,5 м/с и определить коэффициент турбулизации пластинчатого теплообменника. Результаты. Приведены результаты компьютерного моделирования движения теплоносителя в межпластинном гофрированном канале оригинального пластинчатого теплообменного аппарата с помощью программного комплекса Аnsys . Определены критерии устойчивости системы. Выполнено 3 D -моделирование канала, образуемого гофрированными пластинами. При исследовании процесса турбулизации были рассмотрены несколько скоростных режимов движения теплоносителя. Определен коэффициент турбулизации Tu, %. Выводы. В результате компьютерного моделирования установлено увеличение коэффициента теплопередачи К, Вт/(м ℃ ) за счет повышенной турбулизации потока, что приводит к снижению металлоемкости и уменьшению стоимости теплообменного оборудования. Statement of the problem. The heat exchange process occurring in a modified corrugated interplate channel of an intensified plate heat exchanger with an increased turbulence of the heat carrier is discussed. A computer model of the coolant movement in the speed range of 0.1-1.5 m/s is developed and the turbulence coefficient of the plate heat exchanger is determined. Results. The article presents the results of computer modeling of the coolant movement in the interplate corrugated channel of the original plate heat exchanger using the Ansys software package. The criteria of system stability are defined. 3D modeling of the channel formed by corrugated plates is performed. In the study of the process of turbulence several high-speed modes of movement of the coolant were considered. The turbulence coefficient Tu, % is determined. Conclusions. As a result of computer simulation, an increase in the heat transfer coefficient K, W/(m ℃) was found due to an increased turbulization of the flow, which leads to a decrease in metal consumption and a decrease in the cost of heat exchange equipment.


2019 ◽  
Vol 252 ◽  
pp. 05019 ◽  
Author(s):  
Robert Zarzycki ◽  
Justyna Jędras

The study presents the problem of heat exchange in the biomass carbonisation reactor with cyclic operation. Based on the actual parameter of the biomass carbonisation reactor, a geometrical model was developed, and the computation of the heating process was conducted for two cases: an empty reactor and a filled reactor. Its result demonstrated that for the analysed configuration of the reactor, the process of heating biomass in the containers is limited by the capability of heat transfer to the biomass in the container. The results suggest opportunities for the improved heat exchange in the reactor and, accordingly, shortening heating time through installation of the system that forces circulation of hot air inside the reactor.


Author(s):  
A P Pirozhnikova ◽  
M A Govorunov ◽  
T L Pirozhnikova ◽  
G E Muro

2018 ◽  
Vol 245 ◽  
pp. 07002 ◽  
Author(s):  
Vladimir Davletbaev ◽  
Natalia Rydalina ◽  
Elena Antonova

We study heat exchangers at the experimental setup aiming at the energy-saving. The feature of this heat exchange process is of the fact that the working medium is a porous metal. The pores are filled with freon and operation of the refrigeration unit condenser is studied. The scheme of the experimental setup and experiment methodology are given. The results of the experiment and its processing are also presented.