Accuracy of freehand versus modified funnel technique for pedicle screw insertion in the thoracic spine

Author(s):  
Omer Faruk Kilicaslan ◽  
Mehmet Ali Tokgoz ◽  
Sevket Butun ◽  
Vugar Nabi ◽  
Serdar Akalin
Spine ◽  
2006 ◽  
Vol 31 (22) ◽  
pp. E840-E846 ◽  
Author(s):  
Hwan T. Hee ◽  
Mohammad Shazad Khan ◽  
James C. Goh ◽  
Hee K. Wong

2013 ◽  
Vol 19 (2) ◽  
pp. 185-190 ◽  
Author(s):  
Taku Sugawara ◽  
Naoki Higashiyama ◽  
Shuichi Kaneyama ◽  
Masato Takabatake ◽  
Naoko Watanabe ◽  
...  

Object Pedicle screw fixation is a standard procedure of spinal instrumentation, but accurate screw placement is essential to avoid injury to the adjacent structures, such as the vessels, nerves, and viscera. The authors recently developed an intraoperative screw guiding method in which patient-specific laminar templates were used, and verified the accuracy of the multistep procedure in the thoracic spine. Methods Preoperative bone images of the CT scans were analyzed using 3D/multiplanar imaging software and the trajectories of the screws were planned. Plastic templates with screw guiding structures were created for each lamina by using 3D design and printing technology. Three types of templates were made for precise multistep guidance, and all templates were specially designed to fit and lock on the lamina during the procedure. Plastic vertebra models were also generated and preoperative screw insertion simulation was performed. Surgery was performed using this patient-specific screw guide template system, and the placement of screws was postoperatively evaluated using CT scanning. Results Ten patients with thoracic or cervicothoracic pathological entities were selected to verify this novel procedure. Fifty-eight pedicle screws were placed using the screw guide template system. Preoperatively, each template was found to fit exactly and to lock on the lamina of the vertebra models, and screw insertion simulation was successfully performed. Intraoperatively the templates also fit and locked on the patient lamina, and screw insertion was completed successfully. Postoperative CT scans confirmed that no screws violated the cortex of the pedicles, and the mean deviation of the screws from the planned trajectories was 0.87 ± 0.34 mm at the coronal midpoint section of the pedicles. Conclusions The multistep, patient-specific screw guide template system is useful for intraoperative pedicle screw navigation in the thoracic spine. This simple and economical method can improve the accuracy of pedicle screw insertion and reduce the operating time and radiation exposure of spinal fixation surgery.


2019 ◽  
Vol 16 (01) ◽  
pp. 10-13
Author(s):  
Ayusman Satapathy ◽  
Chinmaya Dash ◽  
Arunav Sharma ◽  
Rabi Narayan Sahu

Abstract Aim of the Study This article aims to study the safety and feasibility of Fennell technique of free-hand pedicle screw insertion in thoracic spine. Methods Consecutive 10 patients in whom 40 thoracic pedicle screw were inserted using Fennell’s technique were included in the study. Postoperative computed tomography scan was done in all the patients. Breach in individual pedicle was analyzed using Gertzbein classification. Results A total of 40 screws were placed in the thoracic spine in 10 patients by free-hand technique described by Fennell et al. Out of 40 pedicle screws, 26 were placed at the D10 to D12 level, 8 screws were placed at the D7 to D9 level, and 6 screws were placed at the D1 to D6 level. There was one pedicle with grade 1 lateral breach and one pedicle with grade 1 medial breach as per Gertzbein classification. All other screws were contained within the pedicle (Gertzbein grade 0). None of the patients had any added deficits or wound complications in the postoperative period. Conclusion Thoracic pedicle screw insertion is challenging in nature because of the anatomic variability and proximity of critical structures to the pedicles. Our experience suggests that Fennell technique is a reliable technique, which can be used to place thoracic pedicles consistently, with acceptable rates of pedicle breach. A study involving larger number of patients might prove to establish this technique as an easily reproducible and safe technique for free-hand pedicle screw insertion in thoracic spine.


2019 ◽  
Vol 31 (1) ◽  
pp. 139-146 ◽  
Author(s):  
Camilo A. Molina ◽  
Nicholas Theodore ◽  
A. Karim Ahmed ◽  
Erick M. Westbroek ◽  
Yigal Mirovsky ◽  
...  

OBJECTIVEAugmented reality (AR) is a novel technology that has the potential to increase the technical feasibility, accuracy, and safety of conventional manual and robotic computer-navigated pedicle insertion methods. Visual data are directly projected to the operator’s retina and overlaid onto the surgical field, thereby removing the requirement to shift attention to a remote display. The objective of this study was to assess the comparative accuracy of AR-assisted pedicle screw insertion in comparison to conventional pedicle screw insertion methods.METHODSFive cadaveric male torsos were instrumented bilaterally from T6 to L5 for a total of 120 inserted pedicle screws. Postprocedural CT scans were obtained, and screw insertion accuracy was graded by 2 independent neuroradiologists using both the Gertzbein scale (GS) and a combination of that scale and the Heary classification, referred to in this paper as the Heary-Gertzbein scale (HGS). Non-inferiority analysis was performed, comparing the accuracy to freehand, manual computer-navigated, and robotics-assisted computer-navigated insertion accuracy rates reported in the literature. User experience analysis was conducted via a user experience questionnaire filled out by operators after the procedures.RESULTSThe overall screw placement accuracy achieved with the AR system was 96.7% based on the HGS and 94.6% based on the GS. Insertion accuracy was non-inferior to accuracy reported for manual computer-navigated pedicle insertion based on both the GS and the HGS scores. When compared to accuracy reported for robotics-assisted computer-navigated insertion, accuracy achieved with the AR system was found to be non-inferior when assessed with the GS, but superior when assessed with the HGS. Last, accuracy results achieved with the AR system were found to be superior to results obtained with freehand insertion based on both the HGS and the GS scores. Accuracy results were not found to be inferior in any comparison. User experience analysis yielded “excellent” usability classification.CONCLUSIONSAR-assisted pedicle screw insertion is a technically feasible and accurate insertion method.


2005 ◽  
Vol 12 (2) ◽  
pp. 123
Author(s):  
Young Joon Ahn ◽  
Choon Sung Lee ◽  
Ji Hyo Kim ◽  
Kyeong Il Jeong ◽  
Yung Tae Kim

2009 ◽  
Vol 18 (9) ◽  
pp. 1300-1313 ◽  
Author(s):  
Heiko Koller ◽  
Wolfgang Hitzl ◽  
Frank Acosta ◽  
Mark Tauber ◽  
Juliane Zenner ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document