comparative accuracy
Recently Published Documents


TOTAL DOCUMENTS

235
(FIVE YEARS 65)

H-INDEX

34
(FIVE YEARS 6)

2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Teruhiko Terasawa ◽  
Satoyo Hosono ◽  
Seiju Sasaki ◽  
Keika Hoshi ◽  
Yuri Hamashima ◽  
...  

AbstractTo compare all available accuracy data on screening strategies for identifying cervical intraepithelial neoplasia grade ≥ 2 in healthy asymptomatic women, we performed a systematic review and network meta-analysis. MEDLINE and EMBASE were searched up to October 2020 for paired-design studies of cytology and testing for high-risk genotypes of human papillomavirus (hrHPV). The methods used included a duplicate assessment of eligibility, double extraction of quantitative data, validity assessment, random-effects network meta-analysis of test accuracy, and GRADE rating. Twenty-seven prospective studies (185,269 subjects) were included. The combination of cytology (atypical squamous cells of undetermined significance or higher grades) and hrHPV testing (excepting genotyping for HPV 16 or 18 [HPV16/18]) with the either-positive criterion (OR rule) was the most sensitive/least specific, whereas the same combination with the both-positive criterion (AND rule) was the most specific/least sensitive. Compared with standalone cytology, non-HPV16/18 hrHPV assays were more sensitive/less specific. Two algorithms proposed for primary cytological testing or primary hrHPV testing were ranked in the middle as more sensitive/less specific than standalone cytology and the AND rule combinations but more specific/less sensitive than standalone hrHPV testing and the OR rule combination. Further research is needed to assess these results in population-relevant outcomes at the program level.


2021 ◽  
Vol 14 (9) ◽  
pp. 443
Author(s):  
Joana Almeida ◽  
Raquel M. Gaspar

Equity studies are conducted by professionals, who also provide buy/hold/sell recommendations to investors. Nowadays, target prices determined by financial analysts are publicly available to investors, who may decide to use them for investment purposes. Studying the accuracy of such analysts’ forecasts is, thus, of paramount importance. Based upon empirical data on 50 of the biggest (larger capitalisation) European stocks over a 15-year period, from 2004 to 2019, and using a panel data approach, this is the first study looking at overall accuracy in European stock markets. We find that Bloomberg’s 12-month consensus target prices have no predictive power over future market prices. Our panel results are robust to company fixed effects and subperiod analysis. These results are in line with the (mostly US-based) evidence in the literature. Extending common practice, we perform a comparative accuracy analysis, comparing the accuracy of target prices with that of simple capitalisations of current prices. It turns out target prices are not better at forecasting than simple capitalisations. When considering individual regressions, accuracy is still very low, but it varies considerably across stocks. By also analysing the relationship between both measures—target prices and capitalised prices—we find evidence that, for some stocks, capitalised prices partially explain how target prices are determined.


2021 ◽  
Vol 13 (16) ◽  
pp. 3176
Author(s):  
Beata Hejmanowska ◽  
Piotr Kramarczyk ◽  
Ewa Głowienka ◽  
Sławomir Mikrut

The study presents the analysis of the possible use of limited number of the Sentinel-2 and Sentinel-1 to check if crop declarations that the EU farmers submit to receive subsidies are true. The declarations used in the research were randomly divided into two independent sets (training and test). Based on the training set, supervised classification of both single images and their combinations was performed using random forest algorithm in SNAP (ESA) and our own Python scripts. A comparative accuracy analysis was performed on the basis of two forms of confusion matrix (full confusion matrix commonly used in remote sensing and binary confusion matrix used in machine learning) and various accuracy metrics (overall accuracy, accuracy, specificity, sensitivity, etc.). The highest overall accuracy (81%) was obtained in the simultaneous classification of multitemporal images (three Sentinel-2 and one Sentinel-1). An unexpectedly high accuracy (79%) was achieved in the classification of one Sentinel-2 image at the end of May 2018. Noteworthy is the fact that the accuracy of the random forest method trained on the entire training set is equal 80% while using the sampling method ca. 50%. Based on the analysis of various accuracy metrics, it can be concluded that the metrics used in machine learning, for example: specificity and accuracy, are always higher then the overall accuracy. These metrics should be used with caution, because unlike the overall accuracy, to calculate these metrics, not only true positives but also false positives are used as positive results, giving the impression of higher accuracy. Correct calculation of overall accuracy values is essential for comparative analyzes. Reporting the mean accuracy value for the classes as overall accuracy gives a false impression of high accuracy. In our case, the difference was 10–16% for the validation data, and 25–45% for the test data.


Author(s):  
Ahmad M. Tarawneh ◽  
Shahnawaz Haleem ◽  
Daniel D’Aquino ◽  
Nasir Quraishi

OBJECTIVE The goal of this study was to evaluate the comparative accuracy and safety of navigation-based approaches for cervical pedicle screw (CPS) placement over fluoroscopic techniques. METHODS A systematic search of the literature published between January 2006 and December 2019 relating to CPS instrumentation and the comparative accuracy and safety of fluoroscopic and intraoperative computer-based navigation techniques was conducted. Several databases, including the Cochrane Library, PubMed, and EMBASE, were systematically searched to identify potentially eligible studies. Data relating to CPS insertion accuracy and associated complications, in particular neurovascular complications, were extrapolated from the included studies and summarized for analysis. RESULTS A total of 17 studies were identified from the search methodology. Eleven studies evaluated CPS placement under traditional fluoroscopic guidance and 6 studies addressed outcomes following navigation-assisted placement (3D C-arm or CT-guided placement). Overall, a total of 4278 screws were placed in 1065 patients. Misplacement rates of CPS were significantly lower (p < 0.0001) in navigation-assisted techniques (12.51% [range 2.5%–20.5%]) compared to fluoroscopy-guided techniques (18.8% [range 0%–43.5%]). Fluoroscopy-guided CPS insertion was associated with a significantly higher incidence of postoperative complications relating to neurovascular injuries (p < 0.038), with a mean incidence of 1.9% compared with 0.3% in navigation-assisted techniques. CONCLUSIONS This systematic review supports a logical conclusion that navigation-based techniques confer a statistically significantly more accurate screw placement and resultant lower complication rates.


2021 ◽  
pp. 193229682110004
Author(s):  
Annette Baumstark ◽  
Jochen Mende ◽  
Joji Uchiyama ◽  
Cornelia Haug ◽  
Guido Freckmann

A new insulin patch pump for continuous subcutaneous insulin infusion was developed. The pump is composed of reusable and disposable parts and operates with a stepping motor. This pump was compared to a patch pump and a durable pump regarding basal rate and bolus accuracy. Using a microgravimetric method, boluses of 0.2 U, 1 U and 7 U, and a basal rate of 1 U/h were tested. For all pumps, bolus accuracy was higher when larger volumes were delivered. While median deviations were similar for all pumps, there were differences in the precision of individual boluses and when regarding basal rate delivery divided into 1-h windows.