scholarly journals The Zugspitze radiative closure experiment for quantifying water vapor absorption over the terrestrial and solar infrared – Part 3: Quantification of the mid- and near-infrared water vapor continuum in the 2500 to 7800 cm<sup>−1</sup> spectral range under atmospheric conditions

2016 ◽  
Vol 16 (18) ◽  
pp. 11671-11686 ◽  
Author(s):  
Andreas Reichert ◽  
Ralf Sussmann

Abstract. We present a first quantification of the near-infrared (NIR) water vapor continuum absorption from an atmospheric radiative closure experiment carried out at the Zugspitze (47.42° N, 10.98° E; 2964 m a.s.l.). Continuum quantification is achieved via radiative closure using radiometrically calibrated solar Fourier transform infrared (FTIR) absorption spectra covering the 2500 to 7800 cm−1 spectral range. The dry atmospheric conditions at the Zugspitze site (IWV 1.4 to 3.3 mm) enable continuum quantification even within water vapor absorption bands, while upper limits for continuum absorption can be provided in the centers of window regions. Throughout 75 % of the 2500 to 7800 cm−1 spectral range, the Zugspitze results agree within our estimated uncertainty with the widely used MT_CKD 2.5.2 model (Mlawer et al., 2012). In the wings of water vapor absorption bands, our measurements indicate about 2–5 times stronger continuum absorption than MT_CKD, namely in the 2800 to 3000 cm−1 and 4100 to 4200 cm−1 spectral ranges. The measurements are consistent with the laboratory measurements of Mondelain et al. (2015), which rely on cavity ring-down spectroscopy (CDRS), and the calorimetric–interferometric measurements of Bicknell et al. (2006). Compared to the recent FTIR laboratory studies of Ptashnik et al. (2012, 2013), our measurements are consistent within the estimated errors throughout most of the spectral range. However, in the wings of water vapor absorption bands our measurements indicate typically 2–3 times weaker continuum absorption under atmospheric conditions, namely in the 3200 to 3400, 4050 to 4200, and 6950 to 7050 cm−1 spectral regions.

2016 ◽  
Author(s):  
Andreas Reichert ◽  
Ralf Sussmann

Abstract. We present a first quantification of the near-infrared (NIR) water vapor continuum absorption from an atmospheric radiative closure experiment carried out at Mt. Zugspitze (47.42° N, 10.98° E, 2964 m a.s.l.). Continuum quantification is achieved via radiative closure using radiometrically calibrated solar FTIR absorption spectra covering the 2500 to 7800 cm−1 spectral range. The dry atmospheric conditions at the Zugspitze site (IWV 1.4 to 3.3 mm) enable continuum quantification even within water vapor absorption bands, while upper limits for continuum absorption can be provided in the centers of window regions. Throughout 75 % of the 2500 to 7800 cm−1 spectral range, the Zugspitze results are agree within our estimated uncertainty with the widely used MT_CKD 2.5.2-model (Mlawer et al., 2012). Notable exceptions are the 2800 to 3000 cm−1 and 4100 to 4200 cm−1 spectral ranges, where our measurements indicate about 5 times stronger continuum absorption than MT_CKD. The measurements are consistent with the laboratory measurements of Mondelain et al. (2015), which rely on cavity ring-down spectroscopy (CDRS), and the calorimetric-interferometric measurements of Bicknell et al. (2006). Compared to the recent FTIR laboratory studies of Ptashnik et al. (2012) and (2013), our measurements indicate 2–5 times weaker continuum absorption under atmospheric conditions in the wings of water vapor absorption bands, namely in the 3200 to 3400 cm−1, 4050 to 4200 cm−1, and 6950 to 7050 cm−1 spectral regions.


2016 ◽  
Vol 9 (9) ◽  
pp. 4673-4686 ◽  
Author(s):  
Andreas Reichert ◽  
Markus Rettinger ◽  
Ralf Sussmann

Abstract. Quantitative knowledge of water vapor absorption is crucial for accurate climate simulations. An open science question in this context concerns the strength of the water vapor continuum in the near infrared (NIR) at atmospheric temperatures, which is still to be quantified by measurements. This issue can be addressed with radiative closure experiments using solar absorption spectra. However, the spectra used for water vapor continuum quantification have to be radiometrically calibrated. We present for the first time a method that yields sufficient calibration accuracy for NIR water vapor continuum quantification in an atmospheric closure experiment. Our method combines the Langley method with spectral radiance measurements of a high-temperature blackbody calibration source (<  2000 K). The calibration scheme is demonstrated in the spectral range 2500 to 7800 cm−1, but minor modifications to the method enable calibration also throughout the remainder of the NIR spectral range. The resulting uncertainty (2σ) excluding the contribution due to inaccuracies in the extra-atmospheric solar spectrum (ESS) is below 1 % in window regions and up to 1.7 % within absorption bands. The overall radiometric accuracy of the calibration depends on the ESS uncertainty, on which at present no firm consensus has been reached in the NIR. However, as is shown in the companion publication Reichert and Sussmann (2016), ESS uncertainty is only of minor importance for the specific aim of this study, i.e., the quantification of the water vapor continuum in a closure experiment. The calibration uncertainty estimate is substantiated by the investigation of calibration self-consistency, which yields compatible results within the estimated errors for 91.1 % of the 2500 to 7800 cm−1 range. Additionally, a comparison of a set of calibrated spectra to radiative transfer model calculations yields consistent results within the estimated errors for 97.7 % of the spectral range.


2016 ◽  
Author(s):  
Andreas Reichert ◽  
Markus Rettinger ◽  
Ralf Sussmann

Abstract. Quantitative knowledge of water vapor absorption is crucial for accurate climate simulations. An open science question in this context concerns the strength of the water vapor continuum in the near infrared (NIR) at atmospheric temperatures, which is still to be quantified by measurements. This issue can be addressed with radiative closure experiments using solar absorption spectra. However, the spectra used for water vapor continuum quantification have to be radiometrically calibrated. We present for the first time a method that yields sufficient calibration accuracy for NIR water vapor continuum quantification in an atmospheric closure experiment. Our method combines the Langley method with spectral radiance measurements of a high-temperature blackbody calibration source (< 2000 K). The calibration scheme is demonstrated in the spectral range 2500 to 7800 cm−1, but minor modifications to the method enable calibration also throughout the remainder of the NIR spectral range. The resulting uncertainty (2 σ) is below 1 % in window regions and up to 1.7 % within absorption bands. A validation of this calibration uncertainty estimate is performed by investigation of calibration self-consistency, which yields compatible results within the estimated errors for 91.1 % of the 2500 to 7800 cm−1-range. A second validation effort consists in a comparison of a set of calibrated spectra to radiative transfer model calculations, which are consistent within the estimated errors for 97.7 % of the spectral range.


2003 ◽  
Vol 211 ◽  
pp. 97-102 ◽  
Author(s):  
Bruce Wilking ◽  
Ayman Mikhail ◽  
Glenn Carlson ◽  
Michael R. Meyer ◽  
Thomas Greene

We present an analysis of low-resolution infrared spectra for 25 brown dwarf candidates in the NGC 1333 molecular cloud. Candidates were chosen on the basis of their association with the high column density cloud core, and near-infrared fluxes and colors. We compare the depths of water vapor absorption bands in our candidate objects with a grid of dwarf, subgiant, and giant standards to determine spectral types which are independent of reddening. These data are used to derive effective temperatures and bolometric luminosities which, when combined with theoretical tracks and isochrones for pre-main sequence objects, enable us to estimate masses and ages. Depending on the models considered, a total of 9 to 20 brown dwarfs are identified with a median of age of <1 Myr.


2016 ◽  
Vol 9 (4) ◽  
pp. 1743-1753 ◽  
Author(s):  
Kerry Meyer ◽  
Steven Platnick ◽  
G. Thomas Arnold ◽  
Robert E. Holz ◽  
Paolo Veglio ◽  
...  

Abstract. Previous bi-spectral imager retrievals of cloud optical thickness (COT) and effective particle radius (CER) based on the Nakajima and King (1990) approach, such as those of the operational MODIS cloud optical property retrieval product (MOD06), have typically paired a non-absorbing visible or near-infrared wavelength, sensitive to COT, with an absorbing shortwave or mid-wave infrared wavelength sensitive to CER. However, in practice it is only necessary to select two spectral channels that exhibit a strong contrast in cloud particle absorption. Here it is shown, using eMAS observations obtained during NASA's SEAC4RS field campaign, that selecting two absorbing wavelength channels within the broader 1.88 µm water vapor absorption band, namely the 1.83 and 1.93 µm channels that have sufficient differences in ice crystal single scattering albedo, can yield COT and CER retrievals for thin to moderately thick single-layer cirrus that are reasonably consistent with other solar and IR imager-based and lidar-based retrievals. A distinct advantage of this channel selection for cirrus cloud retrievals is that the below-cloud water vapor absorption minimizes the surface contribution to measured cloudy top-of-atmosphere reflectance, in particular compared to the solar window channels used in heritage retrievals such as MOD06. This reduces retrieval uncertainty resulting from errors in the surface reflectance assumption and reduces the frequency of retrieval failures for thin cirrus clouds.


1947 ◽  
Vol 28 (7) ◽  
pp. 330-334 ◽  
Author(s):  
Bernard Hamermesh ◽  
Frederick Reines ◽  
Serge A. Korff

An instrument that measures small absolute humidity changes by the photoelectric examination of the 9,440 Ångstrom-units absorption band of water vapor is described. The instrument consists of a small source of light which sends its radiation over an air path of less than one and a half meters to a dispersing system. The resulting spectrum then is allowed to fall on two vacuum phototubes; one centered in the 9,400 Ångstrom-units absorption band of water vapor, the other located at 8,000 ngstrom units where no water vapor absorption bands exist. As the absolute humidity in the air path is varied, the phototube in the region of the band is affected; whereas the reference phototube is not. The phototubes are arranged in an amplifying circuit so as to magnify the effect of varying humidity. The instrument uses a portable microammeter instead of the sensitive galvanometer of all previous spectral hygrometers. Humidity changes of 2 to 8 × 10−5 centimeter of precipitable water path over 143 centimeters of air path can be measured. An investigation of the small sensitive range of the instrument was carried out and the results indicate that the device is confined to use over a small humidity range with equipment available at the present time.


2013 ◽  
Vol 26 (1) ◽  
pp. 45-49 ◽  
Author(s):  
M. M. Makogon ◽  
Yu. N. Ponomarev ◽  
B. A. Tikhomirov

Sign in / Sign up

Export Citation Format

Share Document