scholarly journals Simultaneous measurement of <i>δ</i><sup>13</sup>C, <i>δ</i><sup>18</sup>O and <i>δ</i><sup>17</sup>O of atmospheric CO<sub>2</sub> – performance assessment of a dual-laser absorption spectrometer

2021 ◽  
Vol 14 (6) ◽  
pp. 4279-4304
Author(s):  
Pharahilda M. Steur ◽  
Hubertus A. Scheeren ◽  
Dave D. Nelson ◽  
J. Barry McManus ◽  
Harro A. J. Meijer

Abstract. Using laser absorption spectrometry for the measurement of stable isotopes of atmospheric CO2 instead of the traditional isotope ratio mass spectrometry method decreases sample preparation time significantly, and uncertainties in the measurement accuracy due to CO2 extraction and isobaric interferences are avoided. In this study we present the measurement performance of a new dual-laser instrument developed for the simultaneous measurement of the δ13C, δ18O and δ17O of atmospheric CO2 in discrete air samples, referred to as the Stable Isotopes of CO2 Absorption Spectrometer (SICAS). We compare two different calibration methods: the ratio method, based on the measured isotope ratio and a CO2 mole fraction dependency correction, and the isotopologue method, based on measured isotopologue abundances. Calibration with the ratio method and isotopologue method is based on three different assigned whole-air references calibrated on the VPDB (Vienna Pee Dee Belemnite) and the WMO 2007 (World Meteorological Organization) scale for their stable isotope compositions and their CO2 mole fractions, respectively. An additional quality control tank is included in both methods to follow long-term instrument performance. Measurements of the quality control tank show that the measurement precision and accuracy of both calibration methods is of similar quality for δ13C and δ18O measurements. During one specific measurement period the precision and accuracy of the quality control tank reach WMO compatibility requirements, being 0.01 ‰ for δ13C and 0.05 ‰ for δ18O. Uncertainty contributions of the scale uncertainties of the reference gases add another 0.03 ‰ and 0.05 ‰ to the combined uncertainty of the sample measurements. Hence, reaching WMO compatibility for sample measurements on the SICAS requires reduction of the scale uncertainty of the reference gases used for calibration. An intercomparison of flask samples over a wide range of CO2 mole fractions has been conducted with the Max Planck Institute for Biogeochemistry, resulting in a mean residual of 0.01 ‰ and −0.01 ‰ and a standard deviation of 0.05 ‰ and 0.07 ‰ for the δ13C measurements calibrated using the ratio method and the isotopologue method, respectively. The δ18O could not be compared due to depletion of the δ18O signal in our sample flasks because of storage times being too long. Finally, we evaluate the potential of our Δ17O measurements as a tracer for gross primary production by vegetation through photosynthesis. Here, a measurement precision of <0.01 ‰ would be a prerequisite for capturing seasonal variations in the Δ17O signal. Lowest standard errors for the δ17O and Δ17O of the ratio method and the isotopologue method are 0.02 ‰ and 0.02 ‰ and 0.01 ‰ and 0.02 ‰, respectively. The accuracy results show consequently results that are too enriched for both the δ17O and Δ17O measurements for both methods. This is probably due to the fact that two of our reference gases were not measured directly but were determined indirectly. The ratio method shows residuals ranging from 0.06 ‰ to 0.08 ‰ and from 0.06 ‰ to 0.1 ‰ for the δ17O and Δ17O results, respectively. The isotopologue method shows residuals ranging from 0.04 ‰ to 0.1 ‰ and from 0.05 ‰ to 0.13 ‰ for the δ17O and Δ17O results, respectively. Direct determination of the δ17O of all reference gases would improve the accuracy of the δ17O and thereby of the Δ17O measurements.

2020 ◽  
Author(s):  
Pharahilda M. Steur ◽  
Hubertus A. Scheeren ◽  
Dave D. Nelson ◽  
J. Barry McManus ◽  
Harro A. J. Meijer

Abstract. Using laser absorption spectrometry for the measurement of stable isotopes of atmospheric CO2 instead of the traditional Isotope Ratio Mass Spectrometry (IRMS) method decreases sample preparation time significantly, and uncertainties in the measurement accuracy due to CO2 extraction and isobaric interferences are avoided. In this study we present the measurement performance of a new dual-laser instrument developed for the simultaneous measurement of the δ13C, δ18O and δ17O of atmospheric CO2 in discrete air samples, referred to as the Stable Isotopes of CO2 Absorption Spectrometer (SICAS). We compare two different calibration methods: the ratio method (RM) based on measured isotope ratio and a CO2 mole fraction dependency correction (CMFD), and the isotopologue method (IM) based on measured isotopologue abundances. Calibration with the RM and IM is based on three different assigned whole air references calibrated on the VPBD scale. An additional quality control tank (QC) is included in both methods to follow long-term instrument performance. Measurements of the QC tank show that best performance is achieved with the RM for both the δ13C and δ18O measurements with mean residuals of 0.007 ‰ and 0.016 ‰ and mean standard errors of 0.009 ‰ and 0.008 ‰ respectively, during periods of optimal measurement conditions. The δ17O standard error in the same measurement period is 0.013 ‰. In addition, intercomparing a total of 14 different flask samples covering a CO2 mole fraction range of 344–439 ppm with the Max Planck Institute for Biogeochemistry shows a mean residual of 0.002 ‰ and a standard deviation of 0.063 ‰ for δ13C, using the RM. The δ18O could not be compared due to depletion of the δ18O signal in our sample flasks because of too long storage times. Finally, we evaluated the potential of our Δ17O measurements as a tracer for Gross Primary Production (GPP) by vegetation through photosynthesis. Here, a measurement precision of


2019 ◽  
Author(s):  
Chem Int

Recent study was conducted to develop a simple UV spectrophotometric method to determine Phenytoin in bulk and injection form according to official requirement and validate as per ICH guidelines. λmax of Phenytoin was found 202 nm. Linearity existed perceived in the concentration assortment 2-8 μg/ml (r2 = 0.999) for the method. The method was validated pertaining to linearity, precision and accuracy studies, LOD and LOQ consistent with ICH guidelines. The existent method was establish to be simple, linear, precise, accurate as well as sensitive and can be applied for routine quality control enquiry for the analysis of Phenytoin in bulk and injection form.


1978 ◽  
Vol 17 (2) ◽  
pp. 277 ◽  
Author(s):  
A. G. Kjelaas ◽  
P. E. Nordal ◽  
A. Bjerkestrand

Chemosphere ◽  
1993 ◽  
Vol 26 (1-4) ◽  
pp. 13-22 ◽  
Author(s):  
M. Schupp ◽  
P. Bergamaschi ◽  
G.W. Harris ◽  
P.J. Crutzen

2021 ◽  
Author(s):  
◽  
Adrian Peter Paul Jongenelen

<p>This thesis documents the development of a time-of-flight (ToF) camera suitable for autonomous mobile robotics applications. By measuring the round trip time of emitted light to and from objects in the scene, the system is capable of simultaneous full-field range imaging. This is achieved by projecting amplitude modulated continuous wave (AMCW) light onto the scene, and recording the reflection using an image sensor array with a high-speed shutter amplitude modulated at the same frequency (of the order of tens of MHz). The effect is to encode the phase delay of the reflected light as a change in pixel intensity, which is then interpreted as distance. A full field range imaging system has been constructed based on the PMD Technologies PMD19k image sensor, where the high-speed shuttering mechanism is builtin to the integrated circuit. This produces a system that is considerably more compact and power efficient than previous iterations that employed an image intensifier to provide sensor modulation. The new system has comparable performance to commercially available systems in terms of distance measurement precision and accuracy, but is much more flexible with regards to its operating parameters. All of the operating parameters, including the image integration time, sensor modulation phase offset and modulation frequency can be changed in realtime either manually or automatically through software. This highly configurable system serves as an excellent platform for research into novel range imaging techniques. One promising technique is the utilisation of measurements using multiple modulation frequencies in order to maximise precision over an extended operating range. Each measurement gives an independent estimate of the distance with limited range depending on the modulation frequency. These are combined to give a measurement with extended maximum range using a novel algorithm based on the New Chinese Remainder Theorem. A theoretical model for the measurement precision and accuracy of the new algorithm is presented and verified with experimental results. All distance image processing is performed on a per-pixel basis in real-time using a Field Programmable Gate Array (FPGA). An efficient hardware implementation of the phase determination algorithm for calculating distance is investigated. The limiting resource for such an implementation is random access memory (RAM), and a detailed analysis of the trade-off between this resource and measurement precision is also presented.</p>


10.2172/13875 ◽  
1999 ◽  
Author(s):  
B.D. Reid ◽  
D.C. Gerlach ◽  
E.F. Love ◽  
J.P. McNeece ◽  
J.V. Livingston ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document