scholarly journals Metrological characterization and calibration of thermographic cameras for quantitative temperature measurement

2020 ◽  
Vol 9 (2) ◽  
pp. 425-442
Author(s):  
Sebastian König ◽  
Berndt Gutschwager ◽  
Richard Dieter Taubert ◽  
Jörg Hollandt

Abstract. We present the metrological characterization and calibration of three different types of thermographic cameras for quantitative temperature measurement traceable to the International Temperature Scale (ITS-90). Relevant technical specifications – i.e., the non-uniformity of the pixel-to-pixel responsivity, the inhomogeneity equivalent temperature difference (IETD), the noise equivalent temperature difference (NETD), and the size-of-source effect (SSE) – are determined according to the requirements given in the series of Technical Directives VDI/VDE 5585. The measurements are performed with the camera calibration facility of the Physikalisch-Technische Bundesanstalt. The data reference method is applied for the determination and improvement of the non-uniformity, leading to an improved IETD for all three cameras. Finally, the cameras are calibrated according to the different procedures discussed in the VDI/VDE 5585 series. Results achieved with the different calibration procedures are compared for each type of camera and among the three cameras. An uncertainty budget for the calibration of each camera is given according to GUM (ISO, 1995) and VDI/VDE 5585.

2000 ◽  
Vol 66 (643) ◽  
pp. 824-829
Author(s):  
Katashi KUROKAWA ◽  
Masahiro AGU ◽  
Terumi INAGAKI ◽  
Yoshizo OKAMOTO

2006 ◽  
Vol 952 ◽  
Author(s):  
Shusen Huang ◽  
I-Kuan Lin ◽  
Hu Tao ◽  
Xin Zhang

ABSTRACTUncooled double-cantilever microbolometers have the potential of reaching a noise-equivalent temperature difference (NETD) approaching the theoretical limit and thus have gained increasing interest. Each pixel of the device consists of two overlapping bimaterial cantilevers that deflect in opposite directions as their temperature rises due to the absorption of incident infrared radiation. This paper reports recent progress in the development of these double-cantilever focal plane arrays (FPAs), including fabrication and post-process curvature modification.


2010 ◽  
Vol 18 (3) ◽  
Author(s):  
V.V. Vasilyev ◽  
V.S. Varavin ◽  
S.A. Dvoretsky ◽  
I.V. Marchishin ◽  
N.N. Mikhailov ◽  
...  

AbstractA photovoltaic detector design based on the graded band gap HgCdTe MBE structure with high conductivity layer (HCL) at interface, which provides photodiodes series resistance and a shortwave cut.off filter is developed. The optimal HCL parameters giving high quantum efficiency and minimal noise equivalent temperature difference were determined by calculations and experimentally confirmed. The hybrid 320×256 IR FPA operating in 8–12 μm spectral range was fabricated. The threshold power responsivity and minimal noise equivalent temperature difference values at wavelength maximum were 1.02×10−7 W/cm2, 4.1×108 V/W and 27 mK, respectively.


2012 ◽  
Vol 49 (11) ◽  
pp. 111202
Author(s):  
徐世伟 Xu Shiwei ◽  
张悦玲 Zhang Yueling ◽  
王大鹏 Wang Dapeng ◽  
魏东 Wei Dong ◽  
刘万成 Liu Wancheng ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document