scholarly journals Root-cause analysis of bacteraemia increase and surveillance data in hemodialysis

2019 ◽  
Vol 11 (1) ◽  
Author(s):  
Caroline POHL ep OUDIN ◽  
Patricia Sermande ◽  
Evelyne Lenormand ◽  
Johan Bardil ◽  
Ingrid Marianne

ObjectiveTo investigate the bacteraemia increase in haemodialysis sector based on data from specific dialysis nosocomial infections national network surveillance (DIALIN) and through an Association of Litigation and Risk Management protocol (ALARM).IntroductionIn 2017, the dialysis centre of East Reunion Hospital Group (ERHG) based in Saint-Benoit highlighted an increase in bacteraemia’s rates. It was a significant rising compared to previous years. Indeed, ERHG is participating since 2013 to the France haemodialysis infections network surveillance (DIALIN)[1], created in 2005 and that is allowing assessing bacteraemia. DIALIN is a multicentre prospective permanent survey that has followed six voluntary centres in 2005 and forty-two in 2016. Objectives of this network are firstly to produce data about acquired infections in haemodialysis sector such as infection incidence rate and standardized ratios allowing centres to compare themselves and, secondly, to improve the quality of care .The current study describe how a root cause analysis has been conducted through the ALARM risk assessment methodology to set up action plans and to reduce the phenomenon[2][3]MethodsFive years (2013-2017) of ERHG haemodialysis data were obtained from the haemodialysis infections national network surveillance (DIALIN).To investigate and to analyse clinical incidents, the French National Authority for Health (HAS)[2] recommends the use of an Association of Litigation And Risk Management (ALARM) protocol. It is a powerful method for the investigation and analysis of serious incidents by risks managers [4]. Well established in industries sectors, the ALARM method of investigation is well introduced in French healthcare system since the last ten years. It was used to provide root cause analysis of this phenomenon.Individual’s risk factors of each patients (endogenous factors) have been analysed but these risks were identical every year. Thus, we focused on elements different in 2017 from previous years (exogenous factors). We practised audits about hand hygiene, standard precautions, catheter connection and disconnection practices.Our investigations covered several domains of risks or contributary factors such as patient, professional workers, teams, clinical practices protocols, technical and organisational context, care management and Hospital regional health policy.ResultsData from DIALIN pointed out that the ERHG bacteraemia’s rate was similar or lower to the national network until 2016 (n= 0 in 2016 or 1 in 2015 bacteraemia per year only in catheter's access vascular). No infections nor bacteraemia on fistula were noted as showned on figure 1 and figure 2.In 2016, there were 68 haemodialysis chronic patients, 8996 dialysis sessions and incidence of all infections was 0.11 over 1000 sessions.In 2017, there were 84 haemodialysis chronic patients,10377 dialysis sessions and incidence of all infections is 0.77 over 1000 sessions. Bacteraemia’s rate was higher than national network and ERHG previous years.The analysis of potential causes by ALARM method gave us different explanations. First of all, an increase of dialysis sessions and patients number could explain the increase. Then, this method allowed us to highlight a lower hand hygiene indicator for the service and an equipment issue. A batch of extra-corporal-circuit line was defective and a national withdrawal of any batch was initiated thanks to the ERHG. Secondary, the human factors like recruitment of new members with non-compliance of internal processes, management and human resources issues, under stress work conditions, bad working atmosphere, communication issues between haemodialysis professional workers, contributed to the bacteraemia increase. The investigations had also highlighted a misuse of antiseptic serving to catheter 's connection and disconnection process. Some nurses did not respect the activity time of antiseptic and others nurses splashed the antiseptic instead of cleaned with a sterile wipe.Responses have been taken to stop this issue including the cooperation of healthcare team with the support of hygiene expert team. Nevertheless, because of the multiplicity of risk factors and identified roots causes, the phenomenon has not been stop promptly. Despite a slowdown, the phenomenon persists in 2018. Actions have been decided to standardize practices, to work in pairs, and to improve hand hygiene. News equipments and an other antiseptic following national guidelines ( alcoholic chlorhexidin 2%) were chosen by a multidisciplinary team.ConclusionsBacteraemia for dialysis patients might evolve towards serious complications as endocarditis or death in worth cases. During this period, no deaths nor endocarditis linked to bacteraemia have been revealed. The use of a risk management protocol derived from the industry allowed finding roots causes and set up actions plans to solve the phenomenon. ERHG participation to the DIALIN surveillance is continuing.References1.CPIAS, Auvergne Rhône Alpes. Annual report DIALIN ; 2016.2.HAS, Gestion des risques, Grille ALARM. JAM, N°14 août/septembre/octobre ; 2010.3.Reason JT.Human error.New york:Cambridge University Press;1990.4.Vincent C., Taylor-Adams S., Chapman E.J., Hewett D., Prior S., Strange P.,Tizzar A.How to investigate and analyse clinical incidents: clinical Risk Unit and Association of Litigation and Risk Management protocol.BMJ.2000 Mar 18:320(7237):777-781 

2011 ◽  
pp. 78-86
Author(s):  
R. Kilian ◽  
J. Beck ◽  
H. Lang ◽  
V. Schneider ◽  
T. Schönherr ◽  
...  

2012 ◽  
Vol 132 (10) ◽  
pp. 1689-1697
Author(s):  
Yutaka Kudo ◽  
Tomohiro Morimura ◽  
Kiminori Sugauchi ◽  
Tetsuya Masuishi ◽  
Norihisa Komoda

Author(s):  
Dan Bodoh ◽  
Kent Erington ◽  
Kris Dickson ◽  
George Lange ◽  
Carey Wu ◽  
...  

Abstract Laser-assisted device alteration (LADA) is an established technique used to identify critical speed paths in integrated circuits. LADA can reveal the physical location of a speed path, but not the timing of the speed path. This paper describes the root cause analysis benefits of 1064nm time resolved LADA (TR-LADA) with a picosecond laser. It shows several examples of how picosecond TR-LADA has complemented the existing fault isolation toolset and has allowed for quicker resolution of design and manufacturing issues. The paper explains how TR-LADA increases the LADA localization resolution by eliminating the well interaction, provides the timing of the event detected by LADA, indicates the propagation direction of the critical signals detected by LADA, allows the analyst to infer the logic values of the critical signals, and separates multiple interactions occurring at the same site for better understanding of the critical signals.


Author(s):  
Zhigang Song ◽  
Jochonia Nxumalo ◽  
Manuel Villalobos ◽  
Sweta Pendyala

Abstract Pin leakage continues to be on the list of top yield detractors for microelectronics devices. It is simply manifested as elevated current with one pin or several pins during pin continuity test. Although many techniques are capable to globally localize the fault of pin leakage, root cause analysis and identification for it are still very challenging with today’s advanced failure analysis tools and techniques. It is because pin leakage can be caused by any type of defect, at any layer in the device and at any process step. This paper presents a case study to demonstrate how to combine multiple techniques to accurately identify the root cause of a pin leakage issue for a device manufactured using advanced technology node. The root cause was identified as under-etch issue during P+ implantation hard mask opening for ESD protection diode, causing P+ implantation missing, which was responsible for the nearly ohmic type pin leakage.


Sign in / Sign up