Field emission properties of polyacrylonitrile carbon fibers at different processing temperatures

Author(s):  
Y.M. Htwe ◽  
E.P. Sheshin ◽  
K.M. Aung
2010 ◽  
Vol 663-665 ◽  
pp. 183-186 ◽  
Author(s):  
Lan Yang ◽  
Yun Ye ◽  
Tai Liang Guo ◽  
Xiao Jin Huang

Carbon fibers (CNFs) were surfacial metallized by electroless deposited with copper, and their field emission properties were investigated by diode test. The results indicated that the field emission properties of CNFs were affected by the thicknesses of copper. After CNFs were surfacial metallized, the volume resistivity of CNFs was decreased and field emission property was increased, respectively; increase the thin-film thickness, there appeared an optimal film thickness value for properties of field electron emission. It was found that CNFs owned the best field emission properties after electroless depositing for 15 min, with copper metal thickness as 2.1 µm and the volume resistivity down to 2.3510-4 Ω•cm. The field emission tests showed when applied voltage was 562 V, CNFs appeared bright dots, and the high luminance achieved 1388 cd/m2 under applied voltage 1013 V. Further more theoretical analyses, copper coating on CNFs surface is attributed to good electric conductivity, the low work function and the lower attenuation of electron scattering in thin-film.


2012 ◽  
Vol 430-432 ◽  
pp. 627-630
Author(s):  
Lan Yang ◽  
Zhi Jian Ke ◽  
Yun Ye ◽  
Tai Liang Guo

Carbon fibers (CNFs) were surfacial metallized by electroless deposited with nickel, and their field emission properties were investigated by diode test. The results indicated that the CNFs owned better field emission properties after electroless depositing nickel for 30 min, with nickel metal thickness as 3.25 µm and the volume resistivity down to 1.3510-4 Ω•cm. The morphology and composite of Ni-coated CNFs were characterized by scanning electron microscope (SEM) and X-ray diffractions (XRD), respectively. The results indicated Ni-coated CNFs were amorphous and had better surface. The field emission tests showed when applied voltage was 832V, Ni-coated CNFs appeared bright dots, and the high luminance achieved 988cd/m2 under applied voltage 1456V.


2013 ◽  
Vol 9 (5) ◽  
pp. 619-623 ◽  
Author(s):  
Shama Parveen ◽  
Samina Husain ◽  
Avshish Kumar ◽  
Javid Ali ◽  
Mubashshir Husain ◽  
...  

2006 ◽  
Vol 14 (2-3) ◽  
pp. 151-164 ◽  
Author(s):  
A. V. Okotrub ◽  
L. G. Bulusheva ◽  
V. V. Belavin ◽  
A. G. Kudashov ◽  
A. V. Gusel'nikov ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document