DEVELOPMENT AND VALIDATION OF UV-SPECTROPHOTOMETRIC METHOD FOR DETERMINATION OF SELEGILINE HYDROCHLORIDE LOADED SOLID LIPID NANOPARTICLES

INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (08) ◽  
pp. 57-60
Author(s):  
J. B Prajapati ◽  
H Rao ◽  
H Shah ◽  

The present paper discusses about a simple, precise and validated method for the determination of selegiline loaded solid lipid nanoparticles. The study was carried as per the parameters laid down in ICH guidelines. Maximum wavelength of selegiline in 8:2 methanol: chloroform mixture was selected at 258nm. The method was found to be linear in the range of 200μg/mL to 1000μg/mL with correlation coefficient R2 of 0.994. Method was successfully validating as per ICH guidelines. Moreover, this method was simple, sensitive and easy to apply and can be performed at laboratory scale. Hence, the proposed method can be used for analysis of determination of selegiline loaded solid lipid nanoparticles.

INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (08) ◽  
pp. 61-67
Author(s):  
Jagruti B. Prajapati ◽  
Gayatri Patel ◽  

Rotigotine (RTG) loaded Nanostructure Lipid Carriers (NLCs) were developed for the treatment of Parkinson’s disease. To estimate RTG entrapped in NLCs, UV spectrophotometric method was developed and validated. The solvent and wavelength of detection were optimized in order to maximize sensitivity of the proposed method. The method was validated for different parameters like linearity, precision, specificity, accuracy, limit of detection (LOD), limit of quantitation (LOQ) and robustness as per ICH guidelines. A wavelength maximum of RTG in methanol: chloroform (6:4V/V) mixture was found at 273 nm. The method was found to be linear in the range of 40 to 200 µg/mL with a correlation coefficient (r2 ) of 0.998. The accuracy of the method was studied by recovery study and % recovery was found in range of 99 to 100.37 %. The LOD and LOQ were found to be 0.09 µg/mL and 6.1 µg/mL, respectively. The method is simple, accurate and requires relatively inexpensive instrument. The method was used successfully for determination of RTG loaded into NLCs.


INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (03) ◽  
pp. 52-57
Author(s):  
S. D Verma ◽  
J. B. Prajapati ◽  
A. A. Patel ◽  

The objective of work was to develop and validate a UV spectrophotometric method for determination of agomelatine (AGM) loaded in nanostructured lipid carriers (NLCs). The solvent and wavelength of detection were optimized in order to maximize sensitivity of proposed method. The method was validated for different parameters like linearity, precision, specificity, accuracy, limit of detection (LOD), limit of quantitation (LOQ) and robustness as per ICH guidelines. A wavelength maximum of AGM in methanol: chloroform (7:3V/V) mixture was found at 235nm. The method was found to be linear in the range of 1 to 6μg/mL with a correlation coefficient (r2) of 0.997. The accuracy of the method was studied by recovery study and % recovery was found in range of 99 to 100.11%. The LOD and LOQ were found to be 0.043μg/mL and 0.141μg/mL respectively. The method is simple, accurate and requires relatively inexpensive instrument. The method was used successfully for determination of AGM loaded into NLCs.


2011 ◽  
Vol 49 (2) ◽  
pp. 136-141 ◽  
Author(s):  
V. K. Venishetty ◽  
N. Parikh ◽  
R. Sistla ◽  
F. J. Ahmed ◽  
P. V. Diwan

2010 ◽  
Vol 71 (9-10) ◽  
pp. 941-946 ◽  
Author(s):  
Nirali Parikh ◽  
Vinay Kumar Venishetty ◽  
Ramakrishna Sistla

Author(s):  
A.C. Bhosale ◽  
V.C. Bhagat ◽  
V. V Kunjir ◽  
D.P. Kardile ◽  
R.V. Shete

Purpose: Analytical method development and validation for the quantitative determination of Prucalopride succinate in bulk and tablet formulation which plays major role in the development and manufacture of pharmaceuticals. Methods: In the present work a simple, rapid and reproducible UV-Visible Spectrophotometric method was developed and validated according to ICH guidelines. Results and Conclusions: The parameters linearity, specificity, precision, accuracy, and robustness were studied. The wavelength 243nm was selected for the estimation of drug using methanol as a solvent. The drug obeys Beer-lambert’s law over the concentration range 2-10μg/ml. The accuracy of the method was assessed by recovery studies and was found between 97.2- 98.3 %. The method was successfully applied for routine analysis of Prucalopride succinate in bulk and formulation.


Sign in / Sign up

Export Citation Format

Share Document