DEVELOPMENT AND VALIDATION OF UV SPECTROPHOTOMETRIC METHOD FOR THE ESTIMATION OF ROTIGOTINE IN NANOSTRUCTURED LIPID CARRIERS

INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (08) ◽  
pp. 61-67
Author(s):  
Jagruti B. Prajapati ◽  
Gayatri Patel ◽  

Rotigotine (RTG) loaded Nanostructure Lipid Carriers (NLCs) were developed for the treatment of Parkinson’s disease. To estimate RTG entrapped in NLCs, UV spectrophotometric method was developed and validated. The solvent and wavelength of detection were optimized in order to maximize sensitivity of the proposed method. The method was validated for different parameters like linearity, precision, specificity, accuracy, limit of detection (LOD), limit of quantitation (LOQ) and robustness as per ICH guidelines. A wavelength maximum of RTG in methanol: chloroform (6:4V/V) mixture was found at 273 nm. The method was found to be linear in the range of 40 to 200 µg/mL with a correlation coefficient (r2 ) of 0.998. The accuracy of the method was studied by recovery study and % recovery was found in range of 99 to 100.37 %. The LOD and LOQ were found to be 0.09 µg/mL and 6.1 µg/mL, respectively. The method is simple, accurate and requires relatively inexpensive instrument. The method was used successfully for determination of RTG loaded into NLCs.

INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (03) ◽  
pp. 52-57
Author(s):  
S. D Verma ◽  
J. B. Prajapati ◽  
A. A. Patel ◽  

The objective of work was to develop and validate a UV spectrophotometric method for determination of agomelatine (AGM) loaded in nanostructured lipid carriers (NLCs). The solvent and wavelength of detection were optimized in order to maximize sensitivity of proposed method. The method was validated for different parameters like linearity, precision, specificity, accuracy, limit of detection (LOD), limit of quantitation (LOQ) and robustness as per ICH guidelines. A wavelength maximum of AGM in methanol: chloroform (7:3V/V) mixture was found at 235nm. The method was found to be linear in the range of 1 to 6μg/mL with a correlation coefficient (r2) of 0.997. The accuracy of the method was studied by recovery study and % recovery was found in range of 99 to 100.11%. The LOD and LOQ were found to be 0.043μg/mL and 0.141μg/mL respectively. The method is simple, accurate and requires relatively inexpensive instrument. The method was used successfully for determination of AGM loaded into NLCs.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (08) ◽  
pp. 57-60
Author(s):  
J. B Prajapati ◽  
H Rao ◽  
H Shah ◽  

The present paper discusses about a simple, precise and validated method for the determination of selegiline loaded solid lipid nanoparticles. The study was carried as per the parameters laid down in ICH guidelines. Maximum wavelength of selegiline in 8:2 methanol: chloroform mixture was selected at 258nm. The method was found to be linear in the range of 200μg/mL to 1000μg/mL with correlation coefficient R2 of 0.994. Method was successfully validating as per ICH guidelines. Moreover, this method was simple, sensitive and easy to apply and can be performed at laboratory scale. Hence, the proposed method can be used for analysis of determination of selegiline loaded solid lipid nanoparticles.


Author(s):  
Jaspreet Kaur ◽  
Daljit Kaur ◽  
Sukhmeet Singh

Objective: A simple, accurate, and selective ultraviolet-spectrophotometric method has been developed for the estimation of febuxostat in the bulk and pharmaceutical dosage forms.Method: The method was developed and validated according to International Conference on Harmonization (ICH Q2 R1) guidelines. The developed method was validated statistically with respect to linearity, range, precision, accuracy, ruggedness, limit of detection (LOD), limit of quantitation (LOQ), and recovery. Specificity of the method was demonstrated by applying different stressed conditions to drug samples such as acid hydrolysis, alkaline hydrolysis, oxidative, photolytic, and thermal degradation.Results: The study was conducted using phosphate buffer pH 6.8 and λmax was found to be 312 nm. Standard plot having a concentration range of 1–10 μg/ml showed a good linear relationship with R2=0.999. The LOD and LOQ were found to be 0.118 μg/ml and 0.595 μg/ml, respectively. Recovery and percentage relative standard deviations were found to be 100.157±0.332% and <2%, respectively.Conclusion: Proposed method was successfully applicable to the pharmaceutical formulations containing febuxostat. Thus, the developed method is found to be simple, sensitive, accurate, precise, reproducible, and economical for the determination of febuxostat in pharmaceutical dosage forms.


2020 ◽  
Vol 13 (2) ◽  
pp. 60-70
Author(s):  
Harsha Dhurve ◽  
Yasmini Parshuramkar ◽  
Milind Umekar ◽  
Krishna Gupta

A new, simple, specific and economic UV Spectrophotometric method and HPLC method for the estimation of Dofetilide content in bulk and laboratory prepared mixture. UV spectrophotometric detection was carried out at absorption maxima (λmax) at 231nm using methanol as a solvent. The quantitation of drug was carried out using A1% 1cm at 231nm and Beer’s law was obeyed in the concentration range of 2.5-20 μg/ml, with correlation coefficient value less than 1.The chromatographic separation was carried on a C-18 (250 mm × 4.6 mm, 5μ) column using an isocratic mode with a mixture of Acetonitrile:Phosphate Buffer (pH-7) in the ratio of 55:45% v/v as a mobile phase. The flow rate was 1.5ml/min, temperature is maintained at ambient and detection was made at 231 nm using Photodiode array (PDA) detector. The developed method was validated according to ICH guidelines and different analytical parameters such as linearity, precision, accuracy, specificity, limit of detection, limit of quantitation were determined. The percent amount of drug estimated was nearly 100%, found to be a good agreement with label claim of prepared laboratory mixture. The proposed method was validated for its accuracy, precision, robustness, ruggedness, linearity, limit of detection, limit of quantitation and was found to be in range (% RSD<2.0 and SD <±2.0). Both methods were validated and found to be simple, sensitive, accurate, and precise. The results of the study and statistical data proved the applicability of the present method in routine analysis of Dofetilide in bulk as well as laboratory prepared mixture.


2009 ◽  
Vol 6 (s1) ◽  
pp. S163-S170 ◽  
Author(s):  
R. Singh Gujral ◽  
S. Manirul Haque ◽  
P. Shanker

An accurate and validated spectrophotometric method was developed for the determination of gabapentin. This is simple, sensitive and low cost UV spectrophotometric method. The method is based on the direct measurement of the native absorbance of the drug. The detection was done at 210 nm. The method was linear in the range of 0.25 - 3.5 µ g/mL with correlation coefficient of 0.9999. It is validated according to the ICH guidelines with respect to linearity, selectivity, accuracy and precision, limit of quantitation and limit of detection. The method has been applied to assess gabapentin in pharmaceutical formulations with good accuracy and precision and relatively free of interference from coexisting substances.


2017 ◽  
Vol 6 (5) ◽  
pp. 196-199 ◽  
Author(s):  
Shahinaz Mohammed ◽  
Mohammed Adam ◽  
Shaza Shantier

In this study a simple, accurate and precise UV- spectrophotometric method was developed for the estimation of bisoprolol fumarate (BF) in bulk and tablet dosage form. The method was based on measurement of absorbance of BF aqueous solution at 271nm. Validation was conducted in accordance to ICH guidelines. The calibration curve was linear in the concentration range 5-25 µg/mL with correlation coefficient not less than 0.9986. The limit of detection and limit of quantification were 0.22 μg/ml and 0.66 μg/ml, respectively. Intraday and intermediate precision of the developed method were reflected by the low RSD% values (1.19 and 0.854, respectively). The recovery percentage was 105.0 ± 1.3%, n=3. The proposed method was applied for the assay of BF in three different brands


2018 ◽  
Vol 2018 ◽  
pp. 1-7 ◽  
Author(s):  
Sami Bawazeer ◽  
Khalid M. Badr El-Din ◽  
Ahmed M. Abdel-Megied

A simple, rapid, and validated UPLC method was developed for the simultaneous quantitation of paracetamol (PAR), tizanidine (TIZ), aceclofenac (ACF), and nimesulide (NIM) either in pure forms or in their different tablet dosage forms. Chromatographic separation was attained on an ACQUITY UPLC™ BEH C18 column (100 mm × 2.1 mm, 1.7 μm) with a mobile phase consisting of 20 mM phosphate buffer (pH 7.0) : acetonitrile in the proportion (60 : 40 v/v) isocratically pumped at a flow rate of 1.25 mL·min−1, and detection was monitored at 305 nm. All analytes were separated simultaneously at a retention time (tr) of 1.42, 2.31, 3.63, and 5.62 min for PAR, TIZ, ACF, and NIM, respectively, with a total run time less than 6.0 min. The proposed method was validated according to ICH guidelines with respect to accuracy, precision, linearity, limit of detection, limit of quantitation, and robustness. Linearity was obtained over a concentration range of 81.25–487.5, 0.5–3.5, 25–150, and 25–150 µg·mL−1 for PAR, TIZ, ACF, and NIM, respectively. The development method can be successfully employed in QC laboratories for the routine analysis of the investigated drugs in their new combination.


2017 ◽  
Vol 9 (5) ◽  
pp. 102
Author(s):  
Sukhjinder Kaur ◽  
Taranjit Kaur ◽  
Gurdeep Kaur ◽  
Shivani Verma

Objective: The aim of the present work was to develop a simple, rapid, accurate and economical UV-visible spectrophotometric method for the determination of hydroquinone (HQ) in its pure form, marketed formulation as well as in the prepared nanostructured lipid carrier (NLC) systems and to validate the developed method.Methods: HQ was estimated at UV maxima of 289.6 nm in pH 5.5 phosphate buffer using UV-Visible double beam spectrophotometer. Following the guidelines of the International Conference on Harmonization (ICH), the method was validated for various analytical parameters like linearity, precision, and accuracy robustness, ruggedness, limit of detection, quantification limit, and formulation analysis.Results: The obtained results of the analysis were validated statistically. Recovery studies were performed to confirm the accuracy of the proposed method. In the developed method, linearity over the concentration range of 5-40 μg/ml of HQ was observed with the correlation coefficient of 0.998 and found in good agreement with Beer Lambert’s law. The precision (intra-day and inter-day) of the method was found within official RCD limits (RSD<2%).Conclusion: The sensitivity of the method was assessed by determining the limit of detection and limit of quantification. It could be concluded from the results obtained that the purposed method for estimation of HQ in pure form, in the marketed ointment and in the prepared NLC-formulation was simple, rapid, accurate, precise and economical. It can be used successfully in the quality control of pharmaceutical formulations and for the routine laboratory analysis.


2019 ◽  
Vol 9 (4-A) ◽  
pp. 349-354
Author(s):  
BALU KHANDARE ◽  
Atish C. Musle ◽  
Sanket S. Arole ◽  
Pravin V. Popalghat

Abstract: A simple, precise and economical UV-spectrophotometric method has been developed for the estimation of Olmutinib from bulk. Two methods were developed First method (A) applied was area under curve (AUC) in which the area was integrated in wavelength from 262-272nm. Second method (B) was first order derivative spectrometric method. In this method absorbance at λmin=256.57nm, λmax=282.83nm and zero cross=267.68nm was measured. Calibration curves were plotted for the method by using instrumental response at selected wavelength and concentration of analyte in the solution. In both the methods, linearity was observed in the concentration range of 2-12µg/ml at the λmax=267.68nm. Accuracy and precision studies were carried out and results were satisfactorily obtained. The drug at each of the 80 %, 100 % and 120 % levels showed good recoveries that is in the range of 98.00 to 99.00% for both methods, hence it could be said that the method was accurate. Limit of detection (LOD) and limit of quantitation (LOQ) were determined for the method. The method was validated as per International Conference on Harmonization. All validation parameters were within the acceptable limit. The developed method was successfully applied to estimate the amount of Olmutinib in pharmaceutical formulation.


2013 ◽  
Vol 19 (3) ◽  
pp. 333-337 ◽  
Author(s):  
A.C. Arvadiya ◽  
P.P. Dahivelker

A simple, precise, accurate, sensitive and repeatable RP-UPLC method was developed for quantitative determination of atropine sulphate in pharmaceutical dosage form. The method was developed by using C18 column Hiber HR Purospher Star (100mm?2.1mm id, 2?m particle size) as stationary phase with Phosphate Buffer: Acetonitrile (87:13, %v/v) as a mobile phase, pH was adjusted to 3.5 by ortho-phosphoric acid at a flow rate of 0.5 mL/min and column temperature maintained at 30?C. Quantification of eluted compound was achieved with PDA detector at 210 nm. Atropine sulphate followed linearity in concentration range of 2.5-17.5 ?g/mL with r2=0.9998 (n=6). Limit of detection (LOD) and limit of quantification (LOQ) values were 0.0033 and 0.0102 ?g/mL for atropine sulphate. The validation study is carried out as per International Conference on Harmonization (ICH) guidelines. This method was successfully applied for estimation of atropine sulphate in pharmaceutical formulation.


Sign in / Sign up

Export Citation Format

Share Document