scholarly journals Validation of a HPLC Method for the Determination of 4-Hydroxy-3-methoxycinnamyl Alcohol in Extracts Obtained from Stachyurus Chinensis Franeh

2020 ◽  
Vol 12 (3) ◽  
pp. 40
Author(s):  
Jing Ji ◽  
Jie Cao ◽  
Jianming Cheng

Stachyuri medulla helwingiae medulla is a wild used genus in clinic, especially in promoting lactation. Most study confirmed it’s evidently rich in polysaccharide. In this study, a HPLC method for the quantification of Coniferyl alcohol (4-Hydroxy-3-methoxycinnamyl alcohol) was validated. The results showed that the HPLC method was linear (0.01-0.16mg/ml) with good accuracy, precision and robustness. The content of Coniferyl alcohol in different formula granule ranged from 0.091-0.163mg/g. Thus, the method might be used for the standardization of the extracts based on the Coniferyl alcohol marker.

INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (03) ◽  
pp. 44-51
Author(s):  
B. Sabbagh ◽  
B. V. S. Lokesh ◽  
G. A. Akouwah ◽  

Two methods were developed for the determination of dapagliflozin (DAPA) in pure form and in tablets. The procedure utilized was UV-Visible Spectroscopy and RP-HPLC with PDA detector to quantify DAPA in bulk and tablets. The sensitive linear range was identified for both methods within 0.5-5.0μg/mL. The linear regression analysis was identified for both methods with correlation coefficient(r)>0.99. The LOD and LOQ values were found to be 0.05 μg/mL and 0.5 μg/mL for the method by UV-Spectroscopy. The molar absorptivity (ε) was calculated as 1.27 X 105 L.mol-1cm-1. The RP-HPLC method produced LOD and LOQ values of 1.0 ng/mL and 0.5 μg/mL. Both methods were simple, precise, reproducible to quantify the amount of unknown in bulk as well as in tablets and estimated accurately within the range of 100.0±0.5%. Statistical analysis was performed on the data obtained. There was no significant difference between the developed and reported methods with p>0.05. Both methods can be applied for routine analysis of DAPA in bulk and tablets with good accuracy and precision.


2020 ◽  
Vol 58 (8) ◽  
pp. 726-730
Author(s):  
Christina A Sutherland ◽  
David P Nicolau

Abstract A HPLC method was developed and validated to analyze meropenem and vaborbactam simultaneously in murine plasma and saline matrixes. A 60-μL volume of extracted sample was injected onto a 5-μm BDS Phenyl-Hypersil C18 reversed-phase column and analyzed with a UV detector set at 298 nm for the first 4.9 min and switched to 240 nm. The mobile phase contained a mixture of methanol and 25-mM sodium phosphate buffer set at a flow rate of 1.0 mL/min for the 16 min run time. Cefuroxime was used as the internal standard. The standard curves were linear over a range of 0.25–50 μg/mL. The precision and accuracy for 0.25 μg/mL (LLQ) in plasma for both compounds were <4.8% and >98.9%, respectively. Interday and intraday precision and accuracy for all QC plasma samples for both compounds were <6.2% and >95.7%, respectively. This methodology details a reproducible assay for both compounds using a single extraction with good accuracy and precision.


2012 ◽  
Vol 2 (2) ◽  
pp. 364-367 ◽  
Author(s):  
Saida Naik Dheeravath ◽  
◽  
Kasani Ramadevi ◽  
Zilla Saraswathi ◽  
Dheeravath Maniklal ◽  
...  

2019 ◽  
Vol 9 (o3) ◽  
Author(s):  
Imad Tarek Hanoon ◽  
Abed Mohammed Daheir AL-Joubory 2 ◽  
Marwa Mohamed Saied 3

A simple , specific, accurate and precise RP-HPLC method was developed for determination of Irbesartan (IRB) in pharmaceutical dosage forms in tablets products and sachet using symmetry (L 1 ) column at 30°C . The signal was detected at 225 nm. A mobile phase dissolve 0.5 g of buffer potassium phosphate in 100 ml distilled water and adjust pH 2.7 , methanol and acetonitrile at ratio (40 :30 :30 ) . and flow rate 1.2ml/min -1 at pH=7.2 a mobile phase The percent recovery was detected 101 % and the linearity of concentration was 10-50 µg.ml -1 and supported this method by using (FT.I.R.) spectrum method for organic spectrophotometer to prove the chemical structure of this drug and some physical properties . we are obtained the result is identical of other literature . The proposed method was applied successfully for determination of the IRB in tablets products.


Sign in / Sign up

Export Citation Format

Share Document