Screening and Determination of Polycyclic Aromatic Hydrocarbons in Seafoods Using QuEChERS-Based Extraction and High-Performance Liquid Chromatography with Fluorescence Detection

2011 ◽  
Vol 94 (5) ◽  
pp. 1601-1616 ◽  
Author(s):  
Samuel R Gratz ◽  
Laura A Ciolino ◽  
Angela S Mohrhaus ◽  
Bryan M Gamble ◽  
Jill M Gracie ◽  
...  

Abstract A rapid, sensitive, and accurate method for the screening and determination of polycyclic aromatic hydrocarbons (PAHs) in edible seafood is described. The method uses quick, easy, cheap, effective, rugged, and safe (QuEChERS)-based extraction and HPLC with fluorescence detection (FLD). The method was developed and validated in response to the massive Deepwater Horizon oil spill in the Gulf of Mexico. Rapid and highly sensitive PAH screening methods are critical tools needed for oil spill response; they help to assess when seafood is safe for harvesting and consumption. Sample preparation involves SPE of edible seafood portions with acetonitrile, followed by the addition of salts to induce water partitioning. After centrifugation, a portion of the acetonitrile layer is filtered prior to analysis via HPLC-FLD. The chromatographic method uses a polymeric C18 stationary phase designed for PAH analysis with gradient elution, and it resolves 15 U.S. Environmental Protection Agency priority parent PAHs in fewer than 20 min. The procedure was validated in three laboratories for the parent PAHs using spike recovery experiments at PAH fortification levels ranging from 25 to 10 000 μg/kg in oysters, shrimp, crab, and finfish, with recoveries ranging from 78 to 99%. Additional validation was conducted for a series of alkylated homologs of naphthalene, dibenzothiophene, and phenanthrene, with recoveries ranging from 87 to 128%. Method accuracy was further assessed based on analysis of National Institute of Standards and Technology Standard Reference Material 1974b. The method provides method detection limits in the sub to low ppb (μg/kg) range, and practical LOQs in the low ppb (μg/kg) range for most of the PAH compounds studied.

2014 ◽  
Vol 675-677 ◽  
pp. 354-358
Author(s):  
Shi Rong Tang ◽  
Hui Song ◽  
Quan De Liu ◽  
Yao Chen

A rapid extraction method involving ultrasound wave and microwave synergistic extraction (UMSE), followed by sample clean-up on a neutral Al2O3 cartridge, high performance liquid chromatography (HPLC) with fluorescence detection, was optimized for polycyclic aromatic hydrocarbons (PAHs) determination in Ginkgo biloba extracts (GBE). The optimum extraction conditions of UMSE were carried out with 5 g of GBE and 40 mL n-hexane/dichloromethane (1:1, v/v), on ultrasound wave and microwave simultaneous mode of working for 9 min for one time. The extraction mean recovery of total PAHs amounted to 88.69%. The optimized procedure, that presented good analytical performances could be applied to determine PAH content in GBE.


Sign in / Sign up

Export Citation Format

Share Document