scholarly journals Modern Sample Preparation Techniques: A Brief Introduction

2021 ◽  
Author(s):  
Mona Sargazi ◽  
Sayyed Hossein Hashemi ◽  
Massoud Kaykhaii

Due to fast growth in microprocessors, analytical instrumentations in spectroscopy, chromatography, microscopy, sensors and microdevices have been subjected to significant developments. Despite these advances, a sample preparation step is indispensable before instrumental analysis. Main reasons are low sensitivity of the instruments, matrix interferences and incompatibility of the sample with the analytical device. Most of the time spent and most of the errors occurring during a chemical analysis is on sample preparation step. As a result, any improvements in this essential process will have a significant effect on shortening the analysis time and its precision and accuracy and lowering the cost. This introductory chapter intends to draw the readers’ attention to the importance of sample preparation, the procedures of sampling and the source of errors that occur in the course of sampling. The chapter then continues with a heading on sample preparation techniques, including exhaustive and non-exhaustive methods of extraction. Microwave, sonication and membrane-based extraction techniques are more emphasized as exhaustive methods and under a new title, miniaturized methods are discussed. Automation, on-line compatibility and simplification is an important aspect of any sample preparation and extraction which is discussed at the end of this chapter.

2011 ◽  
Vol 4 (4) ◽  
pp. 385-394 ◽  
Author(s):  
J. Meneely ◽  
F. Ricci ◽  
S. Vesco ◽  
M. Abouzied ◽  
M. Sulyok ◽  
...  

Many different immunochemical platforms exist for the screening of naturally occurring contaminants in food from the low cost enzyme linked immunosorbent assays (ELISA) to the expensive instruments such as optical biosensors based on the phenomenon of surface plasmon resonance (SPR). The primary aim of this study was to evaluate and compare a number of these platforms to assess their accuracy and precision when applied to naturally contaminated samples containing HT-2/T-2 mycotoxins. Other important factors considered were the speed of analysis, ease of use (sample preparation techniques and use of the equipment) and ultimately the cost implications. The three screening procedures compared included an SPR biosensor assay, a commercially available ELISA and an enzymelinked immunomagnetic electrochemical array (ELIME array). The qualitative data for all methods demonstrated very good overall agreements with each other, however on comparison with mass spectrometry confirmatory results, the ELISA and SPR assay performed slightly better than the ELIME array, exhibiting an overall agreement of 95.8% compared to 91.7%. Currently, SPR is more costly than the other two platforms and can only be used in the laboratory whereas in theory both the ELISA and ELIME array are portable and can be used in the field, but ultimately this is dependent on the sample preparation techniques employed. Sample preparative techniques varied for all methods evaluated, the ELISA was the most simple to perform followed by that of the SPR method. The ELIME array involved an additional clean-up step thereby increasing both the time and cost of analysis. Therefore in the current format, field use would not be an option for the ELIME array. In relation to speed of analysis, the ELISA outperformed the other methods.


1996 ◽  
Vol 33 (1) ◽  
pp. 147-157 ◽  
Author(s):  
Henrik A. Thomsen ◽  
Kenneth Kisbye

State-of-the-art on-line meters for determination of ammonium, nitrate and phosphate are presented. The on-line meters employ different measuring principles and are available in many different designs differing with respect to size, calibration and cleaning principle, user-friendliness, response time, reagent and sample consumption. A study of Danish experiences on several plants has been conducted. The list price of an on-line meter is between USD 8000 and USD 35,000. To this should be added the cost of sample preparation, design, installation and running-in. The yearly operating for one meter are in the range of USD 200-2500 and the manpower consumption is in the range of 1-5 hours/month. The accuracy obtained is only slightly smaller than the accuracy on collaborative laboratory analyses, which is sufficient for most control purposes.


1998 ◽  
Vol 804 (1-2) ◽  
pp. 55-62 ◽  
Author(s):  
Robert M Montgomery ◽  
Raaidah Saari-Nordhaus ◽  
Lakshmy M Nair ◽  
James M Anderson, Jr

2008 ◽  
Vol 27 (2) ◽  
pp. 151-159 ◽  
Author(s):  
Ligang Chen ◽  
Daqian Song ◽  
Yuan Tian ◽  
Lan Ding ◽  
Aimin Yu ◽  
...  