scholarly journals Applications of the Transthoracic Impedance Signal during Resuscitation

Author(s):  
Digna M. González-Otero ◽  
Sofía Ruiz de Gauna ◽  
José Julio Gutiérrez ◽  
Purificación Saiz ◽  
Jesus M. Ruiz
2007 ◽  
Vol 93 (2) ◽  
pp. 126-132 ◽  
Author(s):  
N Nassi ◽  
R Piumelli ◽  
E Lombardi ◽  
L Landini ◽  
G Donzelli ◽  
...  

1995 ◽  
Vol 18 (9) ◽  
pp. 499-503 ◽  
Author(s):  
F. Pizzarelli ◽  
P. Dattolo ◽  
M. Piacenti ◽  
M.A. Morales ◽  
T. Cerrai ◽  
...  

We studied in 13 hemodialysis patients intradialytic variations of blood volume (BV) and cardiac output, by means of non-invasive methods. We found a weak correlation, r 0.2 or less, between BV variations and intradialysis blood pressure variations. The sensitivity of the former in describing the variations of the latter was only 32%. During the 30 min preceeding the hypotensive crisis the percent BV variations did not show any predictive trend. On the contrary, refilling increased as blood pressure dropped and a weak inverse relation (r -0.35) was found between these two parameters. Unstable patients had predialytic blood volume values significantly lower than stable ones and comparable to healthy subjects. On the contrary, the correlation between percent variations of cardiac output index and MAP was 0.68 with a sensitivity and specificity of 90% and 59%, respectively. Unfortunately these promising results were obtained only with an estimate of cardiac output obtained by echocardiography and not by transthoracic impedance cardiography, which is much more feasible than the former as on-line monitoring of cardiac output. On-line monitoring of hemodynamic parameters is an appealing but still unsolved task.


1986 ◽  
Vol 61 (1) ◽  
pp. 155-159 ◽  
Author(s):  
D. D. Hatcher ◽  
O. D. Srb

This study presents the comparison of two different noninvasive techniques for the estimation of cardiac output (Q). The two techniques used were transthoracic impedance plethysmography (Z) and the indirect Fick CO2 rebreathing (RB) method. Paired estimates of Q were made on 60 different male subjects at rest and during graded increments of work on a cycle ergometer. The mean resting Q as measured by the Z technique (COZ) was 7.46 +/- 0.35 and 5.96 +/- 0.43 l/min using the RB (CORB) technique. At 200 W the mean COZ was 18.67 +/- 0.72 l/min and the CORB was 23.73 +/- 0.84 l/min. Both the techniques were linearly correlated (R) with O2 consumption; i.e., RZ = 0.752, RRB = 0.855. The difference between these two R values is statistically significant (P less than 0.001). A linear relationship was found between the Z and RB techniques at all work loads (R = 0.75). This study suggests that both techniques are equally as reliable over a large range of work loads, with the Z technique being the simplest and most efficient to implement. It was also found that lung volume had no effect on the calculated COZ.


Sign in / Sign up

Export Citation Format

Share Document