Transthoracic Impedance Cardiography: A Survey

1974 ◽  
Author(s):  
James Saklad
1995 ◽  
Vol 18 (9) ◽  
pp. 499-503 ◽  
Author(s):  
F. Pizzarelli ◽  
P. Dattolo ◽  
M. Piacenti ◽  
M.A. Morales ◽  
T. Cerrai ◽  
...  

We studied in 13 hemodialysis patients intradialytic variations of blood volume (BV) and cardiac output, by means of non-invasive methods. We found a weak correlation, r 0.2 or less, between BV variations and intradialysis blood pressure variations. The sensitivity of the former in describing the variations of the latter was only 32%. During the 30 min preceeding the hypotensive crisis the percent BV variations did not show any predictive trend. On the contrary, refilling increased as blood pressure dropped and a weak inverse relation (r -0.35) was found between these two parameters. Unstable patients had predialytic blood volume values significantly lower than stable ones and comparable to healthy subjects. On the contrary, the correlation between percent variations of cardiac output index and MAP was 0.68 with a sensitivity and specificity of 90% and 59%, respectively. Unfortunately these promising results were obtained only with an estimate of cardiac output obtained by echocardiography and not by transthoracic impedance cardiography, which is much more feasible than the former as on-line monitoring of cardiac output. On-line monitoring of hemodynamic parameters is an appealing but still unsolved task.


2018 ◽  
Vol 24 ◽  
pp. 6573-6578
Author(s):  
Saulius Sadauskas ◽  
Albinas Naudžiūnas ◽  
Alvydas Unikauskas ◽  
Edita Mašanauskienė ◽  
Andrius Ališauskas ◽  
...  

1982 ◽  
Vol 63 (2) ◽  
pp. 107-113 ◽  
Author(s):  
A. T. Edmunds ◽  
S. Godfrey ◽  
Marion Tooley

1. Cardiac output measured by transthoracic impedance cardiography has been compared with simultaneous measurements made by the indirect Fick CO2 rebreathing method in nine adults and 14 children. All were healthy normal volunteers. Sixty-six comparisons were made at rest and during steady exercise at work loads up to 100 W. 2. Impedance measurements of cardiac output were consistently higher than indirect Fick measurements of cardiac output, but after application of a correction factor related to packed cell volume there was close correlation between the results obtained by the two methods (r = 0·94). 3. The mean coefficient of variation of impedance measurements of cardiac output was 13% at rest and 5% during steady-state exercise. 4. Changes of lung volume due to breath holding or resulting from addition of an expiratory resistance did not affect the measurement of cardiac output by impedance. 5. Transthoracic impedance cardiography is a rapid, non-invasive technique for measurement of cardiac output. It requires very little active co-operation from the subject. The method would probably give reliable results for patients with respiratory illnesses such as acute asthma or bronchiolitis, during which changes of lung volume may be expected to occur.


Sign in / Sign up

Export Citation Format

Share Document