scholarly journals A novel validated RP-HPLC method development for the estimation of rimonabant hydrochloride in bulk and tablet dosage forms

2011 ◽  
Vol 5 (2) ◽  
pp. 207-213
Author(s):  
Sreekanth Nama
2021 ◽  
Vol 78 (3) ◽  
pp. 305-315
Author(s):  
RAZAN AHMAD ◽  
Mohammad Hailat ◽  
MALAK JABER ◽  
BAYAN ALKHAWAJA ◽  
AMMAR RASRAS ◽  
...  

2013 ◽  
Vol 49 (2) ◽  
pp. 359-366 ◽  
Author(s):  
Mustafa Çelebier ◽  
Tuba Reçber ◽  
Engin Koçak ◽  
Sacide Altinöz

Rivaroxaban, an anti-clotting medication, acts at a crucial point in the blood-clotting process and stops the formation of blood clots. In this study, RP-HPLC method was developed for the determination of rivaroxaban in tablets (Xarelto® (10 mg)). Phenomenex Luna 5 µm C18 100 Å LC Column (250 x 4.6 mm) was used at 40 ºC. Isocratic elution was performed with ACN:Water (55:45 v/v) mixture. The flow rate was 1.2 mL min-1 and UV detection was at 249 nm. Internal standard (Caffeine) and rivaroxaban were eluted within 2.21 and 3.37 minutes, respectively. The developed method was validated according to the ICH guidelines and found to be linear within the range 0.005 - 40.0 µg mL-1. The method was accurate, precise, robust and rapid. Thus, it was applied successfully for the quality control assay of rivaroxaban in tablet dosage form.


2020 ◽  
Vol 10 (1) ◽  
pp. 15
Author(s):  
Prem Kumar Bichala ◽  
R. Suthakaran ◽  
Ch. Shankar ◽  
Syed Ghouse ◽  
Jannet Beula ◽  
...  

2020 ◽  
Vol 10 (1) ◽  
pp. 31-38
Author(s):  
Rahul Suryawanshi ◽  
Siddiqua Shaikh ◽  
Snehal Patil

A new, simple, precise, accurate and reproducible Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method for Simultaneous estimation of bulk and pharmaceutical formulations. Separation of Mirabegron was successfully achieve , C18, 250X4.6mm, 5µm or equivalent in an isocratic mode utilizing methanol water (70:30) at pH 5.0 Adjusted to OPA at a flow rate of 1.0ml/min and eluate was monitored at 243nm, with a retention time of 2.584 minutes for Mirabegron. The method was validated and the response was found to be linear in the drug concentration range of 50µg/ml to150 µg/ml for Mirabegron. The values of the correlation coefficient were found to 0.999for Mirabegron. The Limit of Detection(LOD) and Limit of Quantification (LOQ) for Mirabegron were found to be 0.149 and 0.498 respectively. This method was found to be good percentage recovery were found to be 99 indicates that the proposed method is highly accurate. The specificity of the method shows good correlation between retention times of standard with the sample so, the method specifically determines the analyte in the sample without interference from excipients of tablet dosage forms. The method was extensively validated according to International Council for Harmonisation(ICH) guidelines for Linearity, Accuracy, Precision, Specificity and