scholarly journals RP-HPLC Method Development and Validation for the Estimation of Mirabegron in Bulk and Dosage Form

2020 ◽  
Vol 10 (1) ◽  
pp. 31-38
Author(s):  
Rahul Suryawanshi ◽  
Siddiqua Shaikh ◽  
Snehal Patil

A new, simple, precise, accurate and reproducible Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method for Simultaneous estimation of bulk and pharmaceutical formulations. Separation of Mirabegron was successfully achieve , C18, 250X4.6mm, 5µm or equivalent in an isocratic mode utilizing methanol water (70:30) at pH 5.0 Adjusted to OPA at a flow rate of 1.0ml/min and eluate was monitored at 243nm, with a retention time of 2.584 minutes for Mirabegron. The method was validated and the response was found to be linear in the drug concentration range of 50µg/ml to150 µg/ml for Mirabegron. The values of the correlation coefficient were found to 0.999for Mirabegron. The Limit of Detection(LOD) and Limit of Quantification (LOQ) for Mirabegron were found to be 0.149 and 0.498 respectively. This method was found to be good percentage recovery were found to be 99 indicates that the proposed method is highly accurate. The specificity of the method shows good correlation between retention times of standard with the sample so, the method specifically determines the analyte in the sample without interference from excipients of tablet dosage forms. The method was extensively validated according to International Council for Harmonisation(ICH) guidelines for Linearity, Accuracy, Precision, Specificity and

Author(s):  
Heena Ar Shaikh ◽  
Vandana Jain

Objective: A simple, accurate, precise, robust reverse phase high performance liquid chromatography (RP-HPLC) method was developed for the estimation of telmisartan and nebivolol hydrochloride (HCl) simultaneously in its combined dosage form.Methods: The compounds were well resolved in an isocratic method using the mobile phase composition of acetonitrile: Buffer (potassium dihydrogen orthophosphate pH adjusted 3.1 with orthophosphoric acid) in a ratio of 40:60 v/v at a flow rate of 1.2 ml/min using C18 Shim-pack (150 mm × 4.6 mm, 5 μ) column. The detection was carried out at 280 nm.Results: The retention time of telmisartan and nebivolol HCl was 4.8 min and 6.5 min, respectively. The developed method was validated by evaluating various validation parameters such as linearity, precision, accuracy, robustness, specificity, limit of detection, and limit of quantification according to the international council for harmonization guidelines. The standard calibration curve was obtained in the concentration range of 24–56 μg/ml for telmisartan and 3–7 μg/ml for nebivolol HCl. The overall average % recovery was found out to be 100.35 for telmisartan and 98.84 for nebivolol HCl.Conclusion: Statistical analysis of the data showed that the method is reproducible and selective for the estimation of telmisartan and nebivolol HCl. The proposed method could be used for analysis of telmisartan and nebivolol HCl in their dosage form.


2019 ◽  
Vol 9 (1-s) ◽  
pp. 265-274
Author(s):  
Bindusar Kalia ◽  
Uttam Singh Baghel

This article refers to simple isocratic reverse-phase high-performance liquid chromatographic method (RP-HPLC) developed for the simultaneous quantification of Escitalopram Oxalate (EST) and Clonazepam (CZP) in active pharmaceutical ingredient and pharmaceuticals. The separation of the two drugs was attained using a C₁₈ column (250mm×4.6mm, 5µ) as a stationary phase. The mobile phase was used as a mixture of methanol; acetonitrile; and 0.05M potassium dihydrogen orthophosphate buffer (pH 4 adjusted by orthophosphoric acid) with an isocratic ratio of 40:20:40 v/v. Detection was made by using PDA detector at 210 nm. Escitalopram Oxalate (RT= 4.428 minutes) and Clonazepam (RT= 6.532 minutes) were separated in a single chromatographic run with resolution of 8.719. The calibration plot indicated good linear relationship with r2 = 0.998 for Escitalopram Oxalate in concentration range of 32 µg/ml - 48 µg/ml and r2 = 0.999 for Clonazepam in concentration range of 16 µg/ml - 24 µg/ml. The retrievals for Escitalopram Oxalate and Clonazepam were found to be 99.75% and 99.00%, respectively. The established analytical method was validated and found acceptable as per ICH guidelines for linearity, precision, accuracy, specificity, limit of detection, limit of quantification, robustness and stability. Escitalopram Oxalate and Clonazepam individually as well as in combination were exposed to different stress conditions like acid, base, thermal, photolytic and oxidation degradation and peaks of a degraded product were well determined from peaks of pure drug. This method is modest, quick and appropriate for routine quality control analysis. Keywords: Reverse Phase – HPLC; Escitalopram Oxalate; Clonazepam; Validation; Degradation study.


Author(s):  
G.M. Kadam ◽  
A.L. Puyad ◽  
T.M. Kalyankar

A new, economical, simple, accurate, and precise RP-HPLC method was developed for simultaneous assay and content uniformity determination of Sacubitril and Valsartan in bulk and pharmaceutical dosage form. The separation of Sacubitril and Valsartan was achieved within 6 minutes on Phenomenex Luna C18 250 mm x 4.6mm and 5µm Particle Size, column using Acetonitrile: Methanol: Water (30:55:15% v/v/v) as the mobile phase. Detection was carried out at 250 nm wavelength. The retention time of Sacubitril and Valsartan was found to be 2.361 and 3.304 min, respectively. The validation of the developed method was performed in terms of specificity, accuracy, precision, linearity, the limit of detection, the limit of quantification as mentioned in International Conference on Harmonization (ICH) guidelines. The method showed adequate sensitivity concerning linearity, accuracy, and precision over the range 12-36 μg/ml and 13-39 μg/ml for Sacubitril and Valsartan, respectively. The percentage recoveries obtained for Sacubitril and Valsartan were found to be in the range of 98.00 – 102.00 %. The proposed method is suitable for use in quality-control laboratories for quantitative analysis.


2021 ◽  
pp. 1-11
Author(s):  
Sultan M. Alshahrani ◽  
John Mark Christensen

This study was designed to develop and validate a simple and efficient high performance liquid chromatography (HPLC) method to determine flunixin concentrations in Asian elephant’s (Elephas maximus) plasma. Flunixin was administered orally at a dose of 0.8 mg/kg, and blood samples were collected. Flunixin extraction was performed by adding an equal amount of acetonitrile to plasma and centrifuging at 4500 rpm for 25 minutes. The supernatant was removed, and flunixin was analyzed using HPLC-UV detection. Two methods were developed and tested utilizing two different mobile phases either with or without adding methanol (ACN: H2O vs. ACN: H2O: MeOH). Both methods showed excellent linearity and reproducibility. The limit of detection was 0.05 ug/ml and limit of quantification was 0.1 ug/ml. the efficiency of flunixin recovery was maximized by the addition of methanol to mobile phase (ACN: H2O: MeOH as 50:30:20) at 95% in comparison to 23% without methanol. In conclusion, adding methanol to HPLC methods for extraction of flunixin from elephants’ plasma yielded higher recovery rate than without methanol.


2021 ◽  
Vol 23 (06) ◽  
pp. 992-1000
Author(s):  
Sneha S. Ghule ◽  
◽  
Ashpak M. Tamboli ◽  
Snehal D. Patil ◽  
◽  
...  

A reverse-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of Pyridoxamine dihydrochloride and Acetylcysteine in the marketed formulation is developed. Chromatography carried out at 30oc temperature on Agilent Zorbax Bonus-RP (250 x 4.6 mm, 5 µ) coloum. Coloum using a mobile phase 0.1% trifluroacetic acid in water: acetonitrile (80:20v/v) with flow rate 1ml/min (DAD scan at 210nm). Validation parameters such as system suitability, linearity, precision, accuracy are considered as reported International Conference on Harmonization guidelines. The retention times for Pyridoxamine dihydrochloride and Acetylcysteine are 2 min and 3.4 min. The linearity range for Pyridoxamine dihydrochloride and Acetylcysteine is 30-70 µg/ml and 180-420 µg/ml. The %RSD for accuracy was found to be less than 2%. Hence the proposed method was found to be accurate, precise, reproducible, and specific and can be used for simultaneous analysis of these drugs in tablet formulation.


INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (07) ◽  
pp. 59-65
Author(s):  
Vinita C. Patole ◽  
Shilpa P. Chaudhari ◽  

An attempt was made to develop a simple, selective, rapid and precise high-performance liquid chromatography (HPLC) method for simultaneous estimation of thymol and eugenol. Analysis was performed on a C18 column with the mobile phase consisting of solvent %A (water) and solvent %B (acetonitrile) with the following gradient: 0–1 min, 80 % A, 20 % B; 1–7 min, 40 % A and 60 % B; 7–12 min, 10 % A and 90 % B; and 12–15min, 80 % A and 20 % B at a flow rate of 0.6 mL/min. The compounds were well separated on a Thermo Scientific Hypersil BDS RP C18 column (4.6 mm × 150 mm, dp = 5 µm) and ultraviolet detection at 280 nm. The retention times of eugenol and thymol were 10.5 min and 11.6 min, respectively. Validation of the proposed method was carried out according to the guidelines of the International Council on Harmonization (ICH). The linearity of the method is good for thymol and eugenol over the concentration range of 1–50 ppm, and the r 2 values were 0.9996 for both thymol and eugenol. The calculated limit of detection (LOD) value was 0.5ppm and the limit of quantification (LOQ) value was 1ppm for both the analytes. The intra and interday relative standard deviation (RSD) of the retention time and peak areas was less than 3 %.The established method was appropriate, and the two markers were well resolved, enabling efficient quantitative analysis of thymol and eugenol.


Author(s):  
Sunkara Namratha ◽  
Vijayalakshmi A

Objective: Reversed-phase high-performance liquid chromatographic method (RP-HPLC) was developed for the assessment of lopinavir in the dosage form of tablet.Methods: Chromatogram was run through using Kromosil C18 4.5×150 mm using a mobile phase methanol: water of ratio 65:35% v/v with a rate of flow of 0.8 ml/min, measured by UV spectrometric detection at 265 nm. The method developed was validated in terms of precision, accuracy, linearity, and robustness parameters.Results: Retention time of lopinavir established at 2.482 min and percentage R.S.D of lopinavir found to be 1.0% and 0.5%, respectively. The method shows that good linearity range of 30–150 μg correlation coefficient of lopinavir was 0.997. The limit of detection was 2.97 and limit of quantification was 9.92, respectively. The percent purity of lopinavir was 99.87%.Conclusion: The suggested method (Rp-HPLC) for concurrent assay lopinavir was validated, which is appropriate method for the analysis oflopinavir quantitatively in tablet dosage forms and bulk.


2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Sadana Gangishetty ◽  
Surajpal Verma

The present work describes a simple, rapid, and reproducible reverse phase high performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of clarithromycin (CLA) and paracetamol (PCM). C18 column (Kromasil ODS, 5 µm, 250 × 4.6 mm) and a mobile phase containing phosphate buffer (0.05 M) along with 1-octane sulphonic acid sodium salt monohydrate (0.005 M) adjusted to pH 3.2: acetonitrile (50 : 50 v/v) mixture was used for the separation and quantification. The flow rate was 1.0 mL/min and the eluents were detected by UV detector at 205 nm. The retention times were found to be 2.21 and 3.73 mins, respectively. The developed method was validated according to ICH guidelines Q2 (R1) and found to be linear within the range of 75–175 µg/mL for both drugs. The developed method was applied successfully for assay of clarithromycin and paracetamol in their combined in-house developed dosage forms and in vitro dissolution studies.


Author(s):  
D. Chinababu

Aim: The objective of the study was simplest, accurate, precise and robust reversed phase high performance liquid chromatographic (RP-HPLC) method was developed for the estimation of Velpatasvir (VEL) and Sofosbuvir (SOF) in the bulk and its tablet dosage form. Study Design: The Quantitative and Qualitative estimation and designed forced degradation study of Velpatasvir & Sofosbuvir by RP-HPLC. Place and Duration of Study: The study was carried at Santhiram College of Pharmacy and time taken 4 months. Method: The method was attained by used Waters( 5µm, C18 250 x 4.6 mm) column with mobile phase consists of  0.5 mM disodium hydrogen phosphate buffer pH adjusted to 6.5, with Orthophosphoric acid and Methanol in the ratio of 78:22 v/v, a flow rate of 1.0 mL/min and ultraviolet detection at 285 nm. Results: The method was validated as per ICH guidelines with different parameters, the mean retention times of VEL and SOF were found to be 2.8 & 4.7 min respectively. The resolution between VEL and SOF was found to be 10.66. The Correlation coefficients for calibration curves within the detection range of 32.5 - 97.5 and 125 - 375 µg/mL were 0.999 for VEL and SOF respectively. The LOD and LOQ for VEL and SOF were found to be 0.0068-0.029 µg/mL and 0.104-0.342 µg/mL respectively. Conclusion: The results were indicated that the developed method was used for the routine analysis of VEL & SOF combined form in bulk and its commercial formulation. To the best of our knowledge, there was no method of RP-HPLC for the determination of VEL alone or in combination with SOF molecule.