Assessment of water quality of River Ganga using multivariate statistical technique: Principal component analysis

2016 ◽  
Vol 8 (1) ◽  
pp. 60
Author(s):  
Ruby Pandey ◽  
Anupam Dikshit
2021 ◽  
pp. 141-146
Author(s):  
Carlo Cusatelli ◽  
Massimiliano Giacalone ◽  
Eugenia Nissi

Well being is a multidimensional phenomenon, that cannot be measured by a single descriptive indicator and that, it should be represented by multiple dimensions. It requires, to be measured by combination of different dimensions that can be considered together as components of the phenomenon. This combination can be obtained by applying methodologies knows as Composite Indicators (CIs). CIs are largely used to have a comprehensive view on a phenomenon that cannot be captured by a single indicator. Principal Component Analysis (PCA) is one of the most popular multivariate statistical technique used for reducing data with many dimension, and often well being indicators are obtained using PCA. PCA is implicitly based on a reflective measurement model that it non suitable for all types of indicators. Mazziotta and Pareto (2013) in their paper discuss the use and misuse of PCA for measuring well-being. The classical PCA is not suitable for data collected on the territory because it does not take into account the spatial autocorrelation present in the data. The aim of this paper is to propose the use of Spatial Principal Component Analysis for measuring well being in the Italian Provinces.


2014 ◽  
Vol 675-677 ◽  
pp. 960-963
Author(s):  
Li Feng Sun ◽  
Qing Jie Qi ◽  
Xiao Liang Zhao ◽  
Rui Feng Li

In order to effectively control pollution of sources of drinking water, improve the environmental quality of drinking water and guarantee the sanitation of drinking water, it is very important to assess water source quality. Main factors of drinking water were identified. Then principal component analysis was used to establish assessment model of drinking water, which could ensure that under the condition that the primitive data information was in the smallest loss, a small number of variables were used to replace the integrated multi-dimensional variables to simplify the data structure. The weightings of principal component were determinated as theirs pollution ratios. This paper was based on the theoretical study of principal component analysis, used the monitoring data on water quality of the main water resources in 2013 to evaluate and analyze the water quality of water resources. Analysis content included the main affecting factors, cause of pollution and the degree of pollution.The resulted showed that: the main affecting factors on water quality of Fo Si water source was CODMn, TP, fluoride.


2016 ◽  
Vol 2 (4) ◽  
pp. 211
Author(s):  
Girdhari Lal Chaurasia ◽  
Mahesh Kumar Gupta ◽  
Praveen Kumar Tandon

Water is an essential resource for all the organisms, plants and animals including the human beings. It is the backbone for agricultural and industrial sectors and all the small business units. Increase in human population and economic activities have tremendously increased the demand for large-scale suppliers of fresh water for various competing end users.The quality evaluation of water is represented in terms of physical, chemical and Biological parameters. A particular problem in the case of water quality monitoring is the complexity associated with analyzing the large number of measured variables. The data sets contain rich information about the behavior of the water resources. Multivariate statistical approaches allow deriving hidden information from the data sets about the possible influences of the environment on water quality. Classification, modeling and interpretation of monitored data are the most important steps in the assessment of water quality. The application of different multivariate statistical techniques, such as cluster analysis (CA), principal component analysis (PCA) and factor analysis (FA) help to identify important components or factors accounting for most of the variances of a system. In the present study water samples were analyzed for various physicochemical analyses by different methods following the standards of APHA, BIS and WHO and were subjected to further statistical analysis viz. the cluster analysis to understand the similarity and differences among the various sampling stations.  Three clusters were found. Cluster 1 was marked with 3 sampling locations 1, 3 & 5; Cluster-2 was marked with sampling location-2 and cluster-3 was marked with sampling location-4. Principal component analysis/factor analysis is a pattern reorganization technique which is used to assess the correlation between the observations in terms of different factors which are not observable. Observations correlated either positively or negatively, are likely to be affected by the same factors while the observations which are not correlated are influenced by different factors. In our study three factors explained 99.827% of variances. F1 marked  51.619% of total variances, high positive strong loading with TSS, TS, Temp, TDS, phosphate and moderate with electrical conductivity with loading values of 0.986, 0.970, 0.792, 0.744, 0.695,  0.701, respectively. Factor 2 marked 27.236% of the total variance with moderate positive loading with total alkalinity & temp. with loading values 0.723 & 0.606 respectively. It also explained the moderate negative loading with conductivity, TDS, and chloride with loading values -0.698, -0.690, -0.582. Factor F 3 marked 20.972 % of the variances with positive loading with PH, chloride, and phosphate with strong loading of pH 0.872 and moderate positive loading with chloride and phosphate with loading values 0.721, and 0.569 respectively. 


2018 ◽  
Vol 19 (2) ◽  
pp. 603-609 ◽  
Author(s):  
Weiwei Lu ◽  
Juan Wu ◽  
Zhu Li ◽  
Naxin Cui ◽  
Shuiping Cheng

Abstract Tail water from wastewater treatment plants (WWTP) serves as a major supplementary water source for scenic water bodies, whose water quality is one of the major focuses of public and scientific inquiries. This study investigated the temporal and spatial variations in water quality of Tangxihe River, a eutrophic urban river receiving tail water from a nearby WWTP in Hefei City, using the single-factor index (SFI) and principal component analysis (PCA). The results of SFI indicated that the most important parameters responsible for low water quality were total nitrogen (TN) and ammonia (NH4+-N). PCA showed that tail water from the WWTP greatly reduced water quality, as demonstrated by the significantly increased SFIs and integrated principal component values (F values) of the sampling points around the drain outlet of the WWTP (T3, T4 and T5). The sampling points located at the upstream of the river (T1) and up the water-gate of Chaohu Lake (T6) had negative F values, indicating relatively higher water quality. In addition, the season had a significant effect on the water quality of the river. Moreover, we discuss measures to improve the water quality of urban rivers in order to maintain their ecological functions.


2020 ◽  
Vol 7 (01) ◽  
Author(s):  
RAMA KUMARI ◽  
PARMANAND KUMAR

The present study was conducted for two years to analyze the water quality of the sacred lake Rewalsar. Water quality of different seasons was evaluated by water quality index. Various statistical techniques, such as correlation, principal component analysis were applied. Based on Water Quality Index, water quality of the lake was in the range of 33-80 in different seasons. Cluster analysis of similarity indicates the relationship intensity between the seasons as cluster ranged 80-100% during the study period. In the principal component analysis maximum variables (Conductivity, Alkalinity, Biochemical Oxygen Demand, Nitrates, Phosphates, and Chloride) shows maximum influence during the summer and monsoon. The outcome revealed that the major driving factors of water quality deterioration are the runoff of effluent from the domestic area and offering food materials to the fishes. So, it is necessary to implement effective management strategies for the conservation of the Rewalsarlake.


2016 ◽  
Vol 227 (9) ◽  
Author(s):  
Soraya Moreno Palácio ◽  
Fernando Rodolfo Espinoza-Quiñones ◽  
Aline Roberta de Pauli ◽  
Pitágoras Augusto Piana ◽  
Caroline Bressan Queiroz ◽  
...  

2016 ◽  
Vol 11 (1) ◽  
pp. 89-95 ◽  
Author(s):  
Monikandon Sukumaran ◽  
Kesavan Devarayan

Principal component analysis is a unique technique for reducing the dimensionality of the data. In this study, ten water quality parameters of the river Kaveri observed at five different stations of Tiruchirappalli for six years were collected and subjected to principal component analysis. A computational program was prepared in order to process and understand the data as a cluster. At first necessary data for compiling the program were listed and then fed to the program. Then the outputs were analyzed and possible linear and non-linear relationships between the water quality parameters and the timeline. It is understood that biological oxygen demand and fecal coli had a linear relationship. Further, the results suggested for group of factors that influence the water quality in a particular year.


Sign in / Sign up

Export Citation Format

Share Document