scholarly journals 22. Cervical MR angiography using Helmholtz neck coil

1992 ◽  
Vol 48 (3) ◽  
pp. 480
Keyword(s):  
1998 ◽  
Vol 39 (3) ◽  
pp. 249-256 ◽  
Author(s):  
M. Strotzer ◽  
C. Fellner ◽  
S. Fraunhofer ◽  
J. Gmeinwieser ◽  
H. Albrich ◽  
...  

1998 ◽  
Vol 39 (3) ◽  
pp. 249-256 ◽  
Author(s):  
M. Strotzer ◽  
C. Fellner ◽  
S. Fraunhofer ◽  
J. Gmeinwieser ◽  
H. Albrich ◽  
...  

Purpose: To evaluate the usefulness of a dedicated head-neck coil in preoperative imaging of the supra-aortic arteries Material and Methods: Forty consecutive patients with suspected carotid artery stenosis underwent MR angiography (MRA). Using a dedicated head-neck coil, we made a complete evaluation of the supra-aortic arteries and graded the internal carotid artery (ICA) stenoses. MRA was performed at 1.5 T with: coronal 3D FISP from the aortic arch to the circle of Willis; transverse 2D FLASH and 3D TONE of the carotid bifurcation; transverse 3D TONE of the carotid siphon and the circle of Willis; and transverse 3D FISP of the aortic arch. I.a. digital subtraction angiography (DSA) was used as the reference. ICA stenoses of 70% and more at DSA (NASCET methodology) were regarded as severe Results: Severe ICA stenoses were detected with high sensitivity and specificity: 93% and 92% respectively for coronal 3D FISP; 90% and 85% respectively for transverse 2D FLASH; and 97% and 94% respectively for transverse 3D TONE. The carotid siphon and the intracranial ICA were best depicted by 3D TONE. None of the applied sequences gave a satisfactory visualization of the aortic arch or of the origins of the vertebral arteries Conclusion: With the head-neck coil, the supra-aortic arteries (including the intracranial vessels) were visualized without the need to reposition the patient, but depiction of the aortic arch was not acceptable. The quantification of ICA stenoses was reliable


1992 ◽  
Vol 48 (8) ◽  
pp. 1107
Author(s):  
Toru Sato ◽  
Tsutomu Nakano ◽  
Etsuro Futagami
Keyword(s):  

1997 ◽  
Vol 39 (11) ◽  
pp. 763-771 ◽  
Author(s):  
C. Fellner ◽  
M. Strotzer ◽  
S. Fraunhofer ◽  
P. Held ◽  
V. Spies ◽  
...  

2006 ◽  
Vol 39 (5) ◽  
pp. 13
Author(s):  
ELAINE ZABLOCKI
Keyword(s):  

VASA ◽  
2010 ◽  
Vol 39 (1) ◽  
pp. 85-93 ◽  
Author(s):  
Schubert

The subclavian steal effect indicates atherosclerotic disease of the supraaortic vessels but rarely causes cerebrovascular events in itself. Noninvasive imaging providing detailed anatomic as well as hemodynamic information would therefore be desirable. From a group of 25 consecutive patients referred for MR angiography, four with absent or highly attenuated signal in one of the vertebral arteries on 3D multislab time-of-flight MR angiography were selected to undergo 3D time-resolved contrast-enhanced MR angiography. The time-resolved 3D contrast series (source images and MIPs) were evaluated visually and by graphic analysis of time-intensity curves derived from the respective V1 and V3 segments of both vertebral arteries on the source images. In two cases with high-grade proximal left subclavian stenosis, time-resolved 3D ce-MRA was able to visualise retrograde contrast filling of the left VA. There was a marked delay in time-to-peak between the left and right V1 segments in one case and a shallower slope of enhancement in another. In the other two cases, there was complete or collateralised segmental occlusion of the VAs.


VASA ◽  
2014 ◽  
Vol 43 (4) ◽  
pp. 278-283 ◽  
Author(s):  
Qian Chen ◽  
Rongfeng Qi ◽  
Xiaoqing Cheng ◽  
Changsheng Zhou ◽  
Song Luo ◽  
...  

Background: To evaluate the value of time-of-flight MR angiography (TOF MRA) for the assessment of extracranial-intracranial (EC-IC) bypass in Moyamoya disease in comparison with computed tomography angiography (CTA). Patients and methods: A consecutive series of 23 patients with Moyamoya disease were analyzed retrospectively. Twenty three patients underwent 25 procedures of extracranial-intracranial bypass. Cranial CTA was performed within one week after the surgery to assess bypass patency. Then TOF MRA was scanned within 24 h after CTA on a 3T MRI system. Using 5-point scales (0 = poor to 4 = excellent), two radiologists rated the image quality and vessel integrity of bypass for three segments (extracranial, trepanation, intracranial). Results: Image quality was high in both CTA and TOF MRA (mean quality score 3.84 ± 0.37 and 3.8 ± 0.41), without statistical difference (p = 0.66). Mean scores of TOF MRA with respect to bypass visualization were higher than CTA in the intracranial segment (p = 0.026). No significant difference of bypass visualization regarding the extracranial and trepanation segments was found between TOF MRA and CTA (p = 0.66 and p = 0.34, respectively). For the trepanation segment, TOF MRA showed pseudo lesions in 2 of all 25 cases. Conclusions: 3T TOF MRA, a non-contrast technique not exposing the patients to radiation, proved to be at least equal to CTA for the assessment of EC-IC bypass, and even superior to CTA with respect to the intracranial segment. In addition, readers should be aware of a potential overestimation showing focal pseudo lesions of the bypass at the trepanation segment in TOF MRA.


VASA ◽  
2009 ◽  
Vol 38 (1) ◽  
pp. 66-71 ◽  
Author(s):  
Schubert

We describe a case of aortic coarctation at the level of the infrarenal abdominal aorta which is encountered in less than six individuals in one million. In contrast to aortic narrowing above or including the renal arteries, this seems to be a relatively benign anomaly without systemic hypertension or impaired renal function. For the first time in this type of anomaly, contrast-enhanced MR angiography (ce-MRA) on a multi-receiver channel MR system, with an 8-channel phased array coil and parallel imaging was used. Ce-MRA displayed a tortuous, narrowed aortic segment that was found to be associated with mesenteric artery stenosis and compression of the orthotopic left renal vein, also known as the nutcracker phenomenon. All major aortic branches could be depicted using 3D surface-shaded displays and subvolume maximum intensity projections (MIPs). Collateral vessels of the abdominal wall were identified using whole-volume MIPs. Since the majority of aortic malformations are diagnosed at a younger age, and many suffer from renal insufficiency, we conclude that ce-MRA will eventually place conventional DSA as the modality of choice in malformations of the abdominal aorta.


Sign in / Sign up

Export Citation Format

Share Document