scholarly journals Case Study of Indoor Air Quality and Energy Efficiency in Passive House in Latvia

Author(s):  
Gatis Plavenieks ◽  
Arturs Lesinskis ◽  
Ilze Dimdina
Prostor ◽  
2020 ◽  
Vol 28 (2 (60)) ◽  
pp. 346-359
Author(s):  
Vesna Lovec ◽  
Miroslav Premrov ◽  
Vesna Žegarac Leskovar

The majority of kindergartens situated in the territory of former Yugoslavia need renovation. Apart from their enhanced energy efficiency, renovated buildings will presumably offer better indoor environmental quality. According to the current case study, children using a classroom with new windows installed are exposed to substantially poorer indoor air quality due to airtightness and improper ventilation, which calls attention to a vital technical issue of the current renovation process.


Atmosphere ◽  
2021 ◽  
Vol 12 (6) ◽  
pp. 791
Author(s):  
Gaetano Settimo ◽  
Pasquale Avino

Recently, there has been a great increase in the importance of issues related to energy efficiency [...]


Facilities ◽  
2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Ulrika Uotila ◽  
Arto Saari ◽  
Juha-Matti Kalevi Junnonen ◽  
Lari Eskola

Purpose Poor indoor air quality in schools is a worldwide challenge that poses health risks to pupils and teachers. A possible response to this problem is to modify ventilation. Therefore, the purpose of this paper is to pilot a process of generating alternatives for ventilation redesign, in an early project phase, for a school to be refurbished. Here, severe problems in indoor air quality have been found in the school. Design/methodology/approach Ventilation redesign is investigated in a case study of a school, in which four alternative ventilation strategies are generated and evaluated. The analysis is mainly based on the data gathered from project meetings, site visits and the documents provided by ventilation and condition assessment consultants. Findings Four potential strategies to redesign ventilation in the case school are provided for decision-making in refurbishment in the early project phase. Moreover, the research presents several features to be considered when planning the ventilation strategy of an existing school, including the risk of alterations in air pressure through structures; the target number of pupils in classrooms; implementing and operating costs; and the size of the space that ventilation equipment requires. Research limitations/implications As this study focusses on the early project phase, it provides viewpoints to assist decision-making, but the final decision requires still more accurate calculations and simulations. Originality/value This study demonstrates the decision-making process of ventilation redesign of a school with indoor air problems and provides a set of features to be considered. Hence, it may be beneficial for building owners and municipal authorities who are engaged in planning a refurbishment of an existing building.


2020 ◽  
Vol 24 (1) ◽  
pp. 357-367
Author(s):  
Liva Asere ◽  
Andra Blumberga

AbstractThe energy efficiency – indoor air quality dilemma is well known and the main drawback to operate the mechanical ventilation is electricity costs as concluded from previous studies. Educational buildings are one of the places where future taxpayers spend a lot of time. This paper aims to study an alternative solution on how to reduce energy efficiency – indoor air quality dilemma in educational buildings by adopting systems that use renewable energy sources. A typical education building in Latvia is taken as a case study by changing it from a consumer to prosumer. This building type has a specific electricity usage profile that makes the choice of photovoltaics (PV) power quite challenging so the various power options have been analysed and used for an electricity solution. Also, the more decentralised preference is chosen – disconnect from a public heating provider and using a local system with a pellet boiler. Educational buildings using PV can reduce the electricity tariff, but the payback periods are still not very satisfactory without subsidies. The average electricity tariff per month varies between scenarios and the best one is for the scenario with 30 kW installed power. The educational building partly using 16 kW PV system reduces not only its bill for electricity but also reduces CO2 emissions by around 36 tons. The education buildings as energy prosumers using renewable energy sources are reducing GHG emissions by having high indoor air quality.


Data in Brief ◽  
2018 ◽  
Vol 20 ◽  
pp. 74-79 ◽  
Author(s):  
Zahra Atarodi ◽  
Kamaladdin Karimyan ◽  
Vinod Kumar Gupta ◽  
Morteza Abbasi ◽  
Masoud Moradi

Author(s):  
AR Hawthorne ◽  
CS Dudney ◽  
RL Tyndall ◽  
T Vo-Dinh ◽  
MA Cohen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document