scholarly journals The Effect of Source to Image-Receptor Distance(SID) on Radiation Dose for Digital Chest Radiography

2014 ◽  
Vol 8 (4) ◽  
pp. 203-210 ◽  
Author(s):  
Soonmu Kwon ◽  
Changhee Park ◽  
Jeongkyu Park ◽  
Woonheung Son ◽  
Jaeeun Jung
2008 ◽  
Vol 35 (6Part1) ◽  
pp. 2391-2402 ◽  
Author(s):  
Xinming Liu ◽  
Chris C. Shaw ◽  
Chao-Jen Lai ◽  
Mustafa C. Altunbas ◽  
Lingyun Chen ◽  
...  

Author(s):  
Jenna Ruth Tugwell-Allsup ◽  
Rhys Wyn Morris ◽  
Kate Thomas ◽  
Richard Hibbs ◽  
Andrew England

Objectives: Copper filtration removes lower energy X-ray photons, which do not enhance image quality but would otherwise contribute to patient dose. This study explores the use of additional copper filtration for neonatal mobile chest imaging. Methods: A controlled factorial-designed experiment was used to determine the effect of independent variables on image quality and radiation dose. These variables included: copper filtration (0Cu, 0.1Cu and 0.2Cu), exposure factors, SID and image receptor position (direct +tray). Image quality was evaluated using absolute visual grading analysis (VGA) and contrast-to-noise ratio (CNR) and entrance surface dose (ESD) was derived using an ionising chamber within the central X-ray beam. Results: VGA, CNR and ESD significantly reduced (p < 0.01) when using added copper filtration. For 0.1Cu, the percentage reduction was much greater for ESD (60%) than for VGA (14%) and CNR (20%), respectively. When compared to the optimal combinations of parameters for incubator imaging using no copper filtration, an increase in kV and mAs when using 0.1mmCu resulted in better image quality at the same radiation dose (direct) or, equal image quality at reduced dose (in-tray). The use of 0.1mmCu for neonatal chest imaging with a corresponding increase in kV and mAs is therefore recommended. Conclusions: Using additional copper filtration significantly reduces radiation dose (at increased mAs) without a detrimental effect on image quality. Advances in knowledge: This is the first study, using an anthropomorphic phantom, to explore the use of additional Cu for DR neonatal chest imaging and therefore helps inform practice to standardise and optimise this imaging examination.


Radiology ◽  
1992 ◽  
Vol 185 (3) ◽  
pp. 719-723 ◽  
Author(s):  
J Geleijns ◽  
J J Broerse ◽  
H W Julius ◽  
H A Vrooman ◽  
J Zoetelief ◽  
...  

1999 ◽  
Vol 40 (5) ◽  
pp. 505-509 ◽  
Author(s):  
Z.-G. Yang ◽  
S. Sone ◽  
F. Li ◽  
S. Takashima ◽  
Y. Maruyama ◽  
...  

Author(s):  
Susan J. Copley ◽  
David M. Hansell

Radiographic findings should always be interpreted in conjunction with the clinical picture. Chest radiography—this remains the commonest technique in the investigation of suspected thoracic disease. Advantages are cost, availability, and a significantly lower radiation dose than CT, but even with optimal technique nearly one-third of the lungs are partially obscured by the overlying mediastinum, diaphragm, and ribs....


2019 ◽  
Vol 113 ◽  
pp. 198-203 ◽  
Author(s):  
Sadeq Al-Murshedi ◽  
Peter Hogg ◽  
Annemieke Meijer ◽  
Hendrik Erenstein ◽  
Andrew England