scholarly journals Role of Fine Needle Aspiration Cytology in Evaluation of Bony Lesions

Author(s):  
Arpita Singhvi ◽  
SR Negi ◽  
Hemant Jain ◽  
Meeta Dewal ◽  
Rajnee Joshi ◽  
...  

Introduction: Fine Needle Aspiration Cytology (FNAC) is increasingly being recognised for its diagnostic utility in evaluation of bone tumours. Though open surgical biopsy is the procedure of choice for diagnosis of bony tumours. Aim: To evaluate the efficacy and reliability of FNAC in diagnosis of bony tumours. Materials and Methods: This cross-sectional study included 40 patients with bony lesions from July 2018 to December 2019 in tertiary level centre of Rajasthan. The FNAC was performed after clinical and radiological assessment. The smears were stained using standard techniques. Also, open biopsy was performed in the patients who presented with bony lesions of patients and slides prepared for histopathological examination using standard techniques. The data was entered in Excel sheets and the results were evaluated using Statistical Package for Social Sciences (SPSS) software version 20.0. Results: Adequate material was obtained in FNAC in 29 (72.5%) cases. Out of 29 cases, FNAC results were accurate in 96.5% cases. False Negative report was obtained in one case with no false positives. Sensitivity of FNAC in diagnosing bony lesions comes to be 90% and Specificity was 100%. The Positive Predictive Value (PPV) was 100% and the Negative Predictive Value (NPV) 95.4%. Conclusion: The FNAC is invaluable tool in primary diagnosis of bony lesions. The technique of obtaining sufficient material though needs to be mastered and will definitely improve with more experience and radiologic correlation.

2020 ◽  
Vol 19 (2) ◽  
pp. 84-89
Author(s):  
Shova Kunwar ◽  
Barsha Bajracharya ◽  
Kavita Karmacharya ◽  
Amar Narayan Shrestha

Introduction: Fine needle aspiration cytology is considered as the gold standard for the diagnosis of thyroid nodules. This study aimed to evaluate and compare the accuracy of fine-needle aspiration cytology in the diagnosis of thyroid lesion by comparing it with the corresponding histopathologic diagnosis after thyroidectomy. Methods: This is a retrospective study conducted over five years at a teaching hospital in Kathmandu. Eighty-nine cases of FNAC of thyroid nodule with subsequent histopathological reports were reviewed. The corresponding reports were compared and the accuracy of FNAC diagnosis was evaluated. Results: 87% of the cases were females and the majority of cases were in the age group 41 to 50 years. Among 89 cases, 55 were reported as benign on cytology and 34 were reported as malignant. On histopathological examination, out of 55 cases diagnosed as benign on cytology, 47 cases were diagnosed as benign whereas eight cases were diagnosed as malignant. HPE of 34 cases diagnosed as malignant on cytology showed that 29 were malignant and five were benign. The false-positive rate was 9.6% and the false-negative rate was 21.6%. The sensitivity was 78.3% and specificity was 90.3%. The positive predictive value and negative predictive value were 85.2% and 85.4% respectively. The accuracy of FNAC in differentiating benign from malignant thyroid lesions was 85.3%. Conclusions: The findings of this study showed that FNAC is a sensitive method for the diagnosis of a solid thyroid lesion


2016 ◽  
Vol 2016 ◽  
pp. 1-6 ◽  
Author(s):  
Do Hoon Koo ◽  
KwangSeop Song ◽  
Hyungju Kwon ◽  
Dong Sik Bae ◽  
Ji-hoon Kim ◽  
...  

Background. Fine-needle aspiration cytology (FNAC) is diagnostic standard for thyroid nodules. However, the influence of size on FNAC accuracy remains unclear especially in too small or too large thyroid nodules. The objective of this retrospective cohort study was to investigate the effect of nodule size on FNAC accuracy. Methods. All consecutive patients who underwent thyroidectomy for nodules in 2010 were enrolled. FNAC results (according to the Bethesda system) were compared to pathological diagnosis. The nodules were categorized into groups A–E on the basis of maximal diameter on ultrasound (≤0.5, >0.5–1, >1-2, >2–4, and >4 cm, resp.). Results. There were 502 cases with 690 nodules. Overall FNAC sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 95.4%, 98.2%, 99.4%, 86.4%, and 96.0%, respectively. False-negative rates (FNRs) of groups A–E were 3.2%, 5.1%, 1.3%, 13.3%, and 50%, respectively. Accuracy rates of groups A–E were 96.8%, 94.8%, 99%, 94.7%, and 87.5%, respectively. Conclusion. Although accuracy rates of FNAC in thyroid nodules smaller than 0.5 cm are comparable to the other group, thyroid nodules larger than 4 cm with benign cytology carry a higher risk of malignancy, which suggest that those should be considered for intensive follow-up or repeated biopsy.


2014 ◽  
Vol 19 (2) ◽  
pp. 110-118
Author(s):  
Mohammad Amzad Hossain ◽  
Md Zahedul Alam ◽  
Md Rojibul Haque ◽  
Md Nazmul Haque ◽  
KM Nurul Alam ◽  
...  

Objective: To evaluate the role of Fine Needle Aspiration Cytology in the preoperative diagnosis of malignancy in parotid and submandibular gland neoplasm. Methods: This cross sectional study on 50 cases was conducted in the Department of Otolaryngology and Head-Neck Surgery of Sir Salimullah Medical College Mitford Hospital and Dhaka Medical College Hospital from January’2009 to June 2010. Results: Fine needle aspiration cytology findings of our all 50 cases were compared with postoperative histopathological reports. Out of the 50 cases, in 36(72%) cases of benign neoplasm and 7(14%) cases of malignant neoplasm, pre-operative FNAC findings and post operative histopathological findings were same. In 7 cases, FNAC and post operative histopathological findings did not matched. These were 2 (4%) false positive and 5 (10%) false negative result.In our study sensitivity of FNAC for reporting malignancy was 58.33%, specificity to rule out malignancy was 94.73% and overall accuracy in detecting malignant tumour was 86%. Positive predictive value and negative value were 77.77% and 87.80% respectively. It can be concluded that fine needle aspiration cytology is a safe, cheap and useful preoperative diagnostic tool in the diagnosis of malignancy in parotid and submandibular gland, but as fine needle aspiration cytology partly depends on operator skill, it may give false negative and false positive result. Conclusion: FNAC is a useful preoperative diagnostic tool for malignant parotid and submandibular glands with high specificity and sensitivity. DOI: http://dx.doi.org/10.3329/bjo.v19i2.17634 Bangladesh J Otorhinolaryngol 2013; 19(2): 110-118


2019 ◽  
Vol 2 (2) ◽  
Author(s):  
Rajneesh Madhok ◽  
Ashish Gupta ◽  
Lalit Singh ◽  
Tanu Agarwal

INTRODUCTION: The study is an attempt to evaluate the sensitivity, specificity, positive predictive value, negative predictive value, p Value and complications of CT guided thoracic interventions fine needle aspiration cytology and core biopsy which are used for diagnosing benign and malignant thoracic lesions. MATERIAL AND METHODS: Study included 102 Patients (87 males and 15 females) with age group ranged from 15 to 87 years.A total of 143 CT guided interventions (84 FNAC’s and 59 core biopsies) were performed in 102 patients. The tissue obtained was sent to the laboratory for histopathological and cytological analysis for a final diagnosis which would contribute to patient management. RESULTS: All( 59) core biopsies were successful in procuring adequate tissue for histopathological analysis and the yield of core biopsies was 100% .However out of 84 FNAC’s only 4 were unsuccessful in procuring adequate tissue with a failure rate of 4.8%. Post procedural biopsy complications were only three (2.1%) which were small pneumothorax. There were 75 malignant lesions and 23 benign lesions based on cytology and histopathology (4 were excluded due to inadequate sample). There was good agreement between benign and malignant lesions diagnosed on CT and that diagnosed by pathology. The most common benign and malignant lesions were granulomatous lesion and squamous cell carcinoma. CONCLUSION: Percutaneous CT guided interventions like core biopsy and fine needle aspirations cytology are simple minimal invasive procedures with good patient acceptance and low morbidity and almost negligible mortality. CT guided interventions should be performed early for diagnosis of thoracic lesions.


2009 ◽  
Vol 27 (30) ◽  
pp. 4994-5000 ◽  
Author(s):  
Christiane A. Voit ◽  
Alexander C.J. van Akkooi ◽  
Gregor Schäfer-Hesterberg ◽  
Alfred Schoengen ◽  
Paul I.M. Schmitz ◽  
...  

Purpose Sentinel node (SN) status is the most important prognostic factor for overall survival (OS) for patients with stage I/II melanoma, and the role of the SN procedure as a staging procedure has long been established. However, a less invasive procedure, such as ultrasound (US) -guided fine-needle aspiration cytology (FNAC), would be preferred. The aim of this study was to evaluate the accuracy of US-guided FNAC and compare the results with histology after SN surgery was performed in all patients. Patients and Methods Four hundred consecutive patients who underwent lymphoscintigraphy subsequently underwent a US examination before the SN procedure. When the US examination showed a suspicious or malignant pattern, patients underwent an FNAC. Median Breslow thickness was 1.8 mm; mean follow-up was 42 months (range, 4 to 82 months). We considered the US-guided FNAC positive if either US and/or FNAC were positive. If US was suggestive of abnormality, but FNAC was negative, the US-guided FNAC was considered negative. Results US-guided FNAC identified 51 (65%) of 79 SN metastases. Specificity was 99% (317 of 321), with a positive predictive value of 93% and negative predictive value of 92%. SN-positive identification rate by US-guided FNAC increased from 40% in stage pT1a/b disease to 79% in stage pT4a/b disease. US-guided FNAC detected SN tumors more than 1.0 mm in 86% of cases, SN tumors of 0.1 to 1.0 mm in 46% of cases, and SN tumors less than 0.1 mm in 23% of cases. Estimated 5-year OS rates were 92% for patients with negative US-guided FNAC results and 51% for patients with positive results. Conclusion US-guided FNAC of SNs is highly accurate. Up to 65% of the patients with SN-positive results in our institution could have been spared an SN procedure.


2000 ◽  
Vol 124 (11) ◽  
pp. 1667-1669
Author(s):  
Timothy Myers ◽  
Helen H. Wang

Abstract Objective.—To compare and contrast benign and malignant lesions of the breast that have similar appearances on fine-needle aspiration cytology and that constitute diagnostic pitfalls. Design.—The cytology files (dated November 1995 through May 1998) of the Beth Israel Deaconess Medical Center were searched to identify cases of breast fine-needle aspiration biopsies that were highly cellular and composed of bland-appearing spindle/columnar cells and that could represent either epithelial or stromal cells; these cases were reported as indeterminate (atypical/suspicious) and had subsequent excisional biopsies taken. Results.—Four such cases were found. Two were fibroadenomas and 2 were papillary carcinomas. Their appearances were strikingly similar on aspiration cytology. All cases were prepared with the ThinPrep method. On microscopic examination, all 4 cases were hypercellular and had many single cells and clusters of columnar/elongate cells. Immunocytochemistry proved these cells to be of epithelial origin. At least occasional bipolar stromal cells were seen in the background. The only appreciable difference between the benign and malignant cases was more significant nuclear atypia, which was barely discernible, in the malignant cases. Immunocytochemistry for smooth muscle actin was helpful in 2 cases that had sufficient material. Conclusions.—Some cases of fibroadenomas and papillary carcinomas can be very difficult, if not impossible, to distinguish on fine-needle aspiration cytology. Immunocytochemistry may be helpful if sufficient material is available. To avoid false-negative or false-positive diagnosis on cytology, it is best to report such cases as atypical or suspicious with final diagnosis pending excisional biopsy.


2020 ◽  
Vol 102 (5) ◽  
pp. 340-342
Author(s):  
H Iftikhar ◽  
M Sohail Awan ◽  
M Usman ◽  
A Khoja ◽  
W Khan

Introduction Fine-needle aspiration cytology (FNAC) is an important diagnostic tool used preoperatively for the diagnosis of parotid lump. Mucoepidermoid carcinoma comprises 5–10% of all salivary gland tumours. It poses a diagnostic challenge on FNAC with high false negative rate. The objective of this study was to evaluate the discordance between cytology/FNAC and histopathology in patients with mucoepidermoid carcinoma. Material and methods A cross-sectional study was conducted from 1 January 2010 to 31 December 2014. Patients aged 18 years and above with FNAC or histopathology suggestive of mucoepidermoid carcinoma were identified. FNAC when compared with histology (gold standard) was classified into true positive (presence of mucoepidermoid carcinoma correctly diagnosed on FNAC), true negative (absence of mucoepidermoid carcinoma correctly diagnosed on FNAC), false positive (FNAC incorrectly diagnosed mucoepidermoid carcinoma), false negative (FNAC failed to diagnose mucoepidermoid carcinoma). Results A total of 16 patients fulfilled our eligibility criteria. Seven cytological samples were true positive (ie correctly diagnosed mucoepidermoid carcinoma by FNAC), eight cytological specimens were false negative (ie could not pick up mucoepidermoid carcinoma on FNAC). One case was false positive on cytology (ie diagnosed mucoepidermoid carcinoma on FNAC but was reported to be Warthin’s tumour on histopathology) and none were true negative. Conclusion FNAC is not reliable for diagnosis of mucoepidermoid carcinoma. More than 50% of our patients had discordant results between cytology and histology. We recommend a high index of suspicion for mucoepidermoid carcinoma given the poor yield of cytology.


1993 ◽  
Vol 107 (11) ◽  
pp. 1025-1028 ◽  
Author(s):  
N. J. Roland ◽  
A. W. Caslin ◽  
P. A. Smith ◽  
L. S. Turnbull ◽  
A. Panarese ◽  
...  

AbstractThis paper describes the application of fine needle aspiration cytology (FNAC) performed on92 patients with salivary gland lesions in a Head and Neck Surgery Clinic. The aspirates were immediately reported by a cytopathologist and the reports conveyed to the surgeon during the same clinic visit. FNAC results were then compared with histology in those patients who underwent surgery and with the clinical course of the disease at subsequent clinic visits in patients where surgery was not performed. The cytological diagnosis was incorrect in five cases, one of which was a false negative result. There were no false positive results. The sensitivity was 90.9 per cent and the specificity 100 per cent. This rapid report system of fine needle aspiration cytology has been found to be safe, free of complications, and helpful in the planning of treatment.


2018 ◽  
Vol 90 (5) ◽  
pp. 1-5 ◽  
Author(s):  
Ewa Machała ◽  
Jan Sopiński ◽  
Iulia Iavorska ◽  
Krzysztof Kołomecki

ABSTRACT Fine needle aspiration cytology (FNAC) is considered as the gold standard diagnostic test for the diagnosis of thyroid nodules. It is a cost-effective procedure that provides specific diagnosis rapidly with minimal complications. It plays an important role in the determination of treatment- patients with suspected malignancy diagnosis can be subjected to surgery. On the other hand it can decrease the rate of unnecessary surgeries. Aims: The aim of this study was to evaluate and compare the correlation, accuracy of fine needle aspirational cytology (FNAC) in the diagnosis of thyroid lesions with the final histopathologic diagnosis in the surgical specimens. Materials and Methods: In our study we have performed a retrospective analysis of a case series of patients who were admitted to the Department of Endocrine, General and Oncological Surgery of Hospital of M. Kopernik in Łodź (Poland) between May 2016 and December 2017 and underwent FNAC with subsequent surgery. Cytological diagnosis was classified into six Bethesda categories. Results: On cytological examination 1070/1262 were reported as benign, 49 malignant and 143 suspicious. On histopathological examination, 956/1070 cases were confirmed as benign but there were 114 discordant cases. Among the other cases histopathology diagnosis of malignancy matched in 45/49 and 128/143 cases.The sensitivity and specificity were 60,28% and 98,05% respectively. False positive rate was 1.95% and false negative rate was 39.72%. The positive predictive value was 90.1% and negative predictive value was 89.35%. Accuracy of FNA in differentiating benign from malignant thyroid lesions was 89,46%. Conclusions: Fine needle aspiration cytology is a simple, cost-effective and popular procedure for the diagnosis of thyroid cancer. It is recommended as the first line investigation for the diagnosis of thyroid lessions.


2013 ◽  
Vol 98 (12) ◽  
pp. 4790-4797 ◽  
Author(s):  
Flavia Magri ◽  
Spyridon Chytiris ◽  
Valentina Capelli ◽  
Margherita Gaiti ◽  
Francesca Zerbini ◽  
...  

Context: Ultrasound (US) elastography (USE) was recently been reported as a sensitive, noninvasive tool for identifying thyroid cancer. However, the accuracy of this technique is hampered by the intra- and interoperator variability, some US features of the nodule, and the coexistence of autoimmune thyroid disease (ATD). Objectives: The purpose of this article was to assess the accuracy of USE findings in the differential diagnosis of thyroid nodules compared with other US features to evaluate its feasibility in the presence of ATDs and identify the strain index (SI) cutoff with the highest diagnostic performance. Design: We evaluated 528 consecutive patients for a total of 661 thyroid nodules. All nodules underwent fine-needle aspiration cytology (FNAC) and USE evaluation. The SI was calculated as a ratio of the nodule strain divided by the strain of the softest part of the surrounding normal tissue. Results: The median SI value was significantly higher in THY4 and THY5 than in THY2 nodules in ATD-positive, ATD-negative, and ATD-unknown patients. The cutoff of SI for malignancy was estimated to be 2.905 by receiver operating characteristic curve analysis in a screening set (379 FNAC results), and then tested in a replication set (252 FNAC results). In all cases, a SI value of ≥2.905 conferred to the nodule a significantly greater probability of being malignant. This SI cutoff had the greatest area under the curve, sensitivity, and negative predictive value, compared with the conventional US features of malignancy. Conclusion: The elastographic SI has a high sensitivity, specificity, and negative predictive value for the diagnosis of thyroid malignancy both in the presence and in the absence of ATD. If our data on USE are also confirmed in THY3 nodules, FNAC could be avoided in a number of thyroid nodules with certain features.


Sign in / Sign up

Export Citation Format

Share Document