rapid calibration
Recently Published Documents


TOTAL DOCUMENTS

60
(FIVE YEARS 11)

H-INDEX

11
(FIVE YEARS 2)

2021 ◽  
Vol 1820 (1) ◽  
pp. 012141
Author(s):  
Meng Lu ◽  
Nan Zhang ◽  
Pan Liu ◽  
Jianjun He ◽  
Yabin Zhou ◽  
...  

2020 ◽  
Vol 14 (2) ◽  
pp. 234-241
Author(s):  
Bin Liu ◽  
Qian Qiao ◽  
Fangfang Han

Background: The 3D laser scanner is a non-contact active-sensing system, which has a number of applications. Many patents have been filed on the technologies for calibrating 3D laser scanner. A precise calibration method is important for measuring the accuracy of the 3D laser scanner. The system model contains three categories of parameters to be calibrated which include the camera intrinsic parameters, distortion coefficients and the light plane parameters. Typically, the calibration process is completed in two steps. Based on Zhang’s method, the calibration of the camera intrinsic parameters and distortion coefficients can be performed. Then, 3D feature points on the light plane should precisely be formed and extracted. Finally, the points are used to calculate the light plane parameters. Methods: In this paper, a rapid calibration method is presented. Without any high precision auxiliary device, only one coplanar reference target is used. By using a group of captured images of the coplanar reference target placed in the field of view arbitrarily, calibration can be performed in one step. Based on the constraint from the planes formed by the target in different directions and the camera imaging model, a large amount of 3D points on the light plane can easily be obtained. The light plane equation in the camera coordinates system can be gathered by executing plane fitting to the 3D points. Results: During the experimental process, the developed 3D laser scanner was calibrated by the proposed method. Then, the measuring accuracy of the system was verified with known distance in vertical direction of 1mm with sequential shifting motion generated by precision translation stage. The average value of the measured distances was found to be 1.010mm. The standard deviation was 0.008mm. Conclusion: Experimental results prove that the proposed calibration method is simple and reliable.


2020 ◽  
Vol 64 (4) ◽  
pp. 40406-1-40406-11
Author(s):  
He Huang ◽  
Yizhou Xue ◽  
Dean Luo

Abstract In recent years, a variety of mobile road measurement equipment has emerged and become an important means of collecting spatial information. As an important part of the mobile road measurement system, a camera’s function implementation and data accuracy largely depend on its internal parameters and the rotation and translation parameters corresponding to the world coordinate system. Based on this and on the traditional camera calibration method, radial and tangential distortion for monocular camera calibration is introduced in this article to establish a calibration model, and the nonlinear least-squares Levenberg‐Marquardt optimization algorithm is used in iterative calculation. The parameters provide a solution to the problem of rapid calibration of camera modules in mobile road measurement systems. The camera parameters obtained by the calibration algorithm in this study are used for visual reconstruction. Compared with two Zhang Zhengyou calibration methods optimized by the Gauss‐Newton method, the former has an average pixel offset of 0.28 pixel and the latter has deviations of 0.66 and 0.38 pixel. Using a monocular camera to collect data on geometric targets on a road, the average relative error does not exceed 2.16%. Experiments show that this method can obtain calibration results quickly and accurately.


Author(s):  
Tianrui Luo ◽  
Douglas C. Noll ◽  
Jeffrey A. Fessler ◽  
Jon‐Fredrik Nielsen
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document