brain oxygen
Recently Published Documents


TOTAL DOCUMENTS

200
(FIVE YEARS 25)

H-INDEX

29
(FIVE YEARS 3)

2021 ◽  
Author(s):  
Kai Chen ◽  
Zunxu liu ◽  
Meng-Yun Li ◽  
Lijuan Tang ◽  
Yufeng Zou ◽  
...  

Abstract Background The blood samples of jugular vein and radial artery were obtained from healthy adults by induced oxygen desaturation test under pulse oximetry conditions on each platform. The oxygen saturation of the two blood samples was analyzed and measured by a Co-oximeter. Thus, the oxygen saturation value of jugular vein (SjvO2) and radial artery (SaO2) were obtained. According to the clinical empirical formula Sa/vO2 = 0.7×S jvO2 + 0.3×SaO2, the oxygen saturation value of brain tissue for invasive blood gas analysis was calculated. To calculate the difference between brain oxygen saturation (rSO2) measured by brain oxygen saturation monitor (hereinafter referred to as brain oxygen analyzer) and brain oxygen saturation (Sa/vO2) measured by invasive blood gas analysis, analyze the consistency of brain oxygen saturation measured by brain oxygen saturation analyzer and blood gas analyzer, and calculate the accuracy of brain oxygen saturation monitoring. The blood samples of jugular vein and radial artery were obtained from healthy adults by induced oxygen desaturation test under pulse oximetry conditions on each platform. The oxygen saturation of the two blood samples was analyzed and measured by a Co-oximeter. Thus, the oxygen saturation value of jugular vein (SjvO2) and radial artery (SaO2) were obtained. According to the clinical empirical formula Sa/vO2 = 0.7×S jvO2 + 0.3×SaO2, the oxygen saturation value of brain tissue for invasive blood gas analysis was calculated. To calculate the difference between brain oxygen saturation (rSO2) measured by brain oxygen saturation monitor (hereinafter referred to as brain oxygen analyzer) and brain oxygen saturation (Sa/vO2) measured by invasive blood gas analysis, analyze the consistency of brain oxygen saturation measured by brain oxygen saturation analyzer and blood gas analyzer, and calculate the accuracy of brain oxygen saturation monitoring. MethodsIn healthy adult volunteers, the induced desaturation test, in which blood gas analysis measures the subjects' internal jugular vein and carotid artery blood samples at each pulse oximetry platform range. Clinical trials were conducted to verify the expected effectiveness and safety of the brain oxygen saturation monitor. Ten subjects were selected into the study according to strict inclusion criteria and exclusion criteria. Subjects should monitor their electrocardiogram, pulse, blood pressure, SPO2 and other vital signs, perform retrograde puncture catheterization of internal jugular vein and radial artery catheterization, ensure the safety of subjects during the period, and record the values of blood samples before and after collection. The oxygen was lowered according to the set platform(according to Figure2), and physiological parameters were monitored during the process. There were 9 platforms in total, and each platform lasted about 5 minutes. The oxygen saturation value of jugular vein (SJVO2) and the oxygen saturation value of carotid artery (SaO2) were obtained, and the tissue oxygen saturation value of sa1vO2 was calculated according to the clinical empirical formula SA1VO2 = 0.7xSJVO2 + 0.3xSaO2. During the blood collection process, the blood oxygen saturation (RSO2) of the subjects' brain was continuously monitored by tissue oximeter noninvastively. The consistency of non-invasive monitoring value RSO2 and invasive measurement value sa1vO2 was compared, and scientific statistical analysis was carried out to confirm whether the accuracy of tissue oxygen meter meets clinical requirements. ResultsAbsolute accuracy evaluation: Further linear regression analysis was performed on the non-invasive monitoring value of the test instrument and the blood gas analysis detection value. The fitting linear equation was rSO2=4.89+0.93×Sa/vO2, where the slope was 0.93, close to 1. The regression line was close to the 45° diagonal trend. The correlation coefficient between rSO2 and Sa/vO2 was 0.95, indicating that there was a good correlation between the non-invasive monitoring value and the invasive blood gas analysis value. Trend accuracy evaluation: It can be seen that the average difference between the trend change value of the test instrument monitoring value and the blood gas analysis value is very small (Bs=Means(△rSO2-△Sa/vO2)=-0.32%), indicating that the trend change of the test instrument monitoring value and the blood gas analysis value is basically consistent in statistical significance. The 95% consistency interval of the difference of trend change between the two devices is narrow ([BS-1.96SD, Bs+1.96SD]=[-6.13%, 5.5%]), indicating that the difference of trend change between the two devices has small variation. The above analysis shows that there is a good consistency between the non-invasive monitoring value of the test equipment and the invasive test results of the blood gas analysis equipment. The linear regression analysis was made on the changes of the test instrument monitoring value and blood gas analysis detection value. The fitting linear equation was △rSO2=-0.98+0.93△Sa/vO2, and the slope was 0.93, which was close to 1. The regression line was close to the 45° diagonal trend. The correlation coefficient of trend changes of the two equipment is 0.95, indicating that the change trend of the test equipment and blood gas analyzer has a good correlation. Analyze the trend changes value, due to the variation of every subjects is relative to the first platform first blood gas analysis values as the base to calculate, so the data points less than 10 absolute value analysis, the test equipment and the trend of blood gas analysis change the average deviation is 0.32%, the standard deviation is 2.97%, RMS very different trend is 2.97%, The clinical evaluation standard of trend Arms≤5% was met. ConclusionThere is good correlation and consistency between the test instrument monitoring value and the absolute value of blood gas analyzer.Trial Registration: The study has been retrospectively registered in Chinese Clinical Trial Registration with the registration number ChiCTR2100052321, date of registration 24/10/2021.


2021 ◽  
pp. 0271678X2110480
Author(s):  
Junghun Cho ◽  
Thanh D Nguyen ◽  
Weiyuan Huang ◽  
Elizabeth M Sweeney ◽  
Xianfu Luo ◽  
...  

We aimed to demonstrate the feasibility of whole brain oxygen extraction fraction (OEF) mapping for measuring lesion specific and regional OEF abnormalities in multiple sclerosis (MS) patients. In 22 MS patients and 11 healthy controls (HC), OEF and neural tissue susceptibility ([Formula: see text]) maps were computed from MRI multi-echo gradient echo data. In MS patients, 80 chronic active lesions with hyperintense rim on quantitative susceptibility mapping were identified, and the mean OEF and [Formula: see text] within the rim and core were compared using linear mixed-effect model analysis. The rim showed higher OEF and [Formula: see text] than the core: relative to their adjacent normal appearing white matter, OEF contrast = −6.6 ± 7.0% vs. −9.8 ± 7.8% (p < 0.001) and [Formula: see text] contrast = 33.9 ± 20.3 ppb vs. 25.7 ± 20.5 ppb (p = 0.017). Between MS and HC, OEF and [Formula: see text]were compared using a linear regression model in subject-based regions of interest. In the whole brain, compared to HC, MS had lower OEF, 30.4 ± 3.3% vs. 21.4 ± 4.4% (p < 0.001), and higher [Formula: see text], −23.7 ± 7.0 ppb vs. −11.3 ± 7.7 ppb (p = 0.018). Our feasibility study suggests that OEF may serve as a useful quantitative marker of tissue oxygen utilization in MS.


Author(s):  
Georgia Tsaousi ◽  
Alessio Tramontana ◽  
Farouk Yamani ◽  
Federico Bilotta

2021 ◽  
Vol 154 ◽  
pp. 105335
Author(s):  
Renaud C. Gom ◽  
Dhyey Bhatt ◽  
Bianca R. Villa ◽  
Antis G. George ◽  
Alexander W. Lohman ◽  
...  

Author(s):  
D. N. Sankovets ◽  
T. V. Gnedko ◽  
A. M. Vitushka ◽  
O. Ja. Svirskaya

NIRS provides the ability to obtain information about the brain oxygen status non-invasively. Therefore, potentially, this technology can make it possible to correct therapy that affects the blood and oxygen supply to the brain.The aim of our study was to develop a guideline for a dynamic monitoring of the oxygen status based on regional oxygenation data, as well as an effective therapeutic tool for newborns with respiratory distress.78 newborns with respiratory disorders were included (37 late preterm and 41 full-term) in this observational cohort study. In addition to a standard cardiorespiratory monitoring, a simultaneous monitoring of abdominal and cerebral oxygenation was performed during the early neonatal period.The developed treatment guideline was based on a multisystem approach in diagnosis and optimization of the brain oxygen delivery and consumption. The proposed algorithm focused on maintaining an adequate perfusion pressure, cardiac output, oxygen, and carbon dioxide content in the arterial blood in newborns with respiratory disorders.Implementing the developed treatment guideline in the neonatal intensive care units should increase the treatment effectiveness in newborns with respiratory disorders.Implementation developed treatment guideline in the neonatal intensive care units should increase the effectiveness of treatment in newborns with respiratory disorders.


2020 ◽  
Vol 34 (12) ◽  
pp. 3275-3281
Author(s):  
Oksana Kamenskaya ◽  
Asya Klinkova ◽  
Irina Loginova ◽  
Vladimir V. Lomivorotov ◽  
Vladimir Shmyrev ◽  
...  

NeuroImage ◽  
2020 ◽  
Vol 220 ◽  
pp. 117136 ◽  
Author(s):  
Audrey P. Fan ◽  
Hongyu An ◽  
Farshad Moradi ◽  
Jarrett Rosenberg ◽  
Yosuke Ishii ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document